For more Information
please call
1-800-Belden1
General Description:
Series 59, 20 AWG solid .032" bare copper-covered steel conductor, plenum, foam FEP insulation,
Duofoil® (100% coverage) + TC braid shield (95% coverage), Flamarrest® jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
120 Solid BCCS - Bare Copper Covered Steel 0.8128
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Trade Name Insulation Material Dia. (mm)
Teflon® FFEP - Foam Fluorinated Ethylene Propylene 3.556
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Duofoil® Tape Aluminum Foil-Polyester Tape 100.000
2Braid TC - Tinned Copper 95.000
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest® LS PVC - Low Smoke Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 5.131 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: 0°C To +75°C
Non-UL Temperature Rating: 75°C
Bulk Cable Weight: 47.622 Kg/Km
Max. Recommended Pulling Tension: 444.820 N
Min. Bend Radius/Minor Axis: 50.800 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMP, CATVP
CEC/C(UL) Specification: CMP, CXC
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: No
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
82108 Coax - CATV Cable
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
RG Type: 59/U
Series Type: Series 59
Flame Test
UL Flame Test: NFPA 262
CSA Flame Test: FT4, FT6
Plenum/Non-Plenum
Plenum (Y/N): Yes
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.29529
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
54.1365
Nominal Velocity of Propagation:
VP (%)
82
Nominal Delay:
Delay (ns/m)
4.06844
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
85.306
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
8.5306
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
10 2.6248
50 5.9058
100 8.5306
200 12.1397
400 17.7174
700 23.9513
900 27.5604
1000 29.2009
Max. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
10 3.01852
50 6.8901
100 9.5149
200 13.7802
400 19.3579
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
82108 Coax - CATV Cable
700 25.9199
900 29.529
1000 30.8414
Max. Operating Voltage - UL:
Voltage
300 V RMS
Other Electrical Characteristic 1: Max Attenuation 10 MHz and above = 0.2856*Freq(MHz)^0.5065
Minimum Structural Return Loss:
Description Freq. (MHz) Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB)
10 400 20
Sweep Test
Sweep Testing: 10 - 400 MHz
Misc. Information (Overall)
Notes (Overall)
Notes: Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
82108 877U1000 305 MT 15.422 KG NATURAL #20 FFEP RG 59/U FLRST
82108 8771000 305 MT 15.422 KG NATURAL C #20 FFEP RG-59/U FLRST
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 3 Revision Date: 09-24-2012
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
82108 Coax - CATV Cable