Description
These small outline high CMR, high speed, logic gate
opto coup lers are single channel devices in a five lead
miniature foot print. They are electrically equivalent to
the following Avago optocouplers (except there is no
output enable feature):
SO-5 Package Standard DIP SO-8 Package
HCPL-M600 6N137 HCPL-0600
HCPL-M601 HCPL-2601 HCPL-0601
HCPL-M611 HCPL-2611 HCPL-0611
The SO-5 JEDEC registered (MO-155) package outline
does not require “through holes in a PCB. This package
occupies approximately one fourth the footprint area of
the standard dual-in-line package. The lead profile is de-
signed to be com patible with standard surface mount
processes.
The HCPL-M600/01/11 optically coupled gates combine
a GaAsP light emitting diode and an integrated high
gain photon detector. The output of the detector I.C.
is an Open-collector Schottky-clamped transistor. The
internal shield provides a guaranteed common mode
transient immunity specification of 5,000 V/μs for the
HCPL-M601, and 10,000 V/μs for the HCPL-M611.
This unique design provides maximum ac and dc circuit
isolation while achieving TTL compatibility. The optocou-
pler ac and dc operational param eters are guaranteed from
–40°C to 85°C allowing trouble free system performance.
HCPL-M600, HCPL-M601, HCPL-M611
Small Outline, 5 Lead, High CMR,
High Speed, Logic Gate Optocouplers
Data Sheet
Features
x Surface Mountable
x Very Small, Low Profile JEDEC Registered Package
Outline
x Compatible with Infrared Vapor Phase Reflow and
Wave Soldering Processes
x Internal Shield for High Common Mode Rejection (CMR)
HCPL-M601: 10,000 V/μs at VCM = 50 V
HCPL-M611: 15,000 V/μs at VCM = 1000 V
x High Speed: 10 Mbd
x LSTTL/TTL Compatible
x Low Input Current Capability: 5 mA
x Guaranteed ac and dc Performance over Temperature:
–40°C to 85°C
x Safety and regulatory approvals:
- UL recognized: 3750 Vac for 1 min. per U.L.
(File No. 55361)
- CSA component acceptance Notice #5
- IEC/EN/DIN EN 60747-5-2 approved for HCPL-M601/
M611 Option 060.
x Lead Free Option
Applications
x Isolated Line Receiver
x Simplex/Multiplex Data Transmission
x Computer-Peripheral Interface
x Microprocessor System Interface
x Digital Isolation for A/D, D/A Conversion
x Switching Power Supply
x Instrument Input/Output Isolation
x Ground Loop Elimination
x Pulse Transformer Replacement
CAUTION: The small device geometries inherent to the design of this bipolar component increase the component's
suscep ti bility to damage from electrostatic discharge (ESD). It is advised that normal static precautions be taken in
handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD.
Lead (Pb) Free
RoHS 6 fully
compliant
RoHS 6 fully compliant options available;
-xxxE denotes a lead-free product
2
The SO-5 JEDEC registered (MO-155) package outline
does not require “through holes in a PCB. This package
occupies approximately one fourth the footprint area of
the standard dual-in-line package. The lead profile is de-
signed to be com patible with standard surface mount
processes.
The HCPL-M600/01/11 optically coupled gates combine
a GaAsP light emitting diode and an integrated high
gain photon detector. The output of the detector I.C.
is an Open-collector Schottky-clamped transistor. The
internal shield provides a guaranteed common mode
transient immunity specification of 5,000 V/μs for the
HCPL-M601, and 10,000 V/μs for the HCPL-M611.
This unique design provides maximum ac and dc circuit
isolation while achieving TTL compatibility. The opto-
coupler ac and dc operational param eters are guaran-
teed from -40°C to 85°C allowing trouble free system
performance.
The HCPL-M600/01/11 are suitable for high speed logic
interfacing, input/output buffering, as line receivers in
environments that conventional line receivers cannot
tolerate, and are recommended for use in extremely
high ground or induced noise environments.
Ordering Information
HCPL-xxxx is UL Recognized with 3750 Vrms for 1 minute per UL1577.
Part
number
Option
Package
Surface
Mount
Gull
Wing
Tape&
Reel
UL 5000 Vrms/
1 Minute rating
IEC/EN/DIN EN
60747-5-2 Quantity
RoHS
Compliant
Non RoHS
Compliant
HCPL-M600 -000E No option SO-5 X 100 per tube
-500E #500 X X 1500 per reel
HCPL-M601
HCPL-M611
-000E No option
SO-5
X 100 per tube
-500E #500 X X 1500 per reel
-560E - X X X 1500 per reel
To order, choose a part number from the part number column and combine with the desired option from the op-
tion column to form an order entry. Combination of Option 020 and Option 060 is not available.
Example 1:
HCPL-M600-500E to order product of Surface Mount SO-5 package in Tape and Reel packaging with RoHS
compliant.
Example 2:
HCPL-M601 to order product of Surface Mount SO-5 package in tube packaging and non RoHS compliant.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
Remarks:
The notation ‘#XXX’ is used for existing products, while (new) products launched since 15th July 2001 and RoHS compliant option will use ‘-XXXE‘.
3
Outline Drawing (JEDEC MO-155)
Land Pattern Recommendation Schematic
HCPL-M601/11 SHIELD
6
5
4
1
3
USE OF A 0.1 μF BYPASS CAPACITOR
MUST BE CONNECTED BETWEEN PINS
6 AND 4 (SEE NOTE 1).
I
F
I
CC
V
CC
V
O
GND
I
O
+
TRUTH TABLE
(POSITIVE LOGIC)
LED
ON
OFF
OUTPUT
L
H
MXXX
XXX
6
5
43
1
7.0 ± 0.2
(0.276 ± 0.008)
2.5 ± 0.1
(0.098 ± 0.004)
0.102 ± 0.102
(0.004 ± 0.004)
VCC
VOUT
GNDCATHODE
ANODE
4.4 ± 0.1
(0.173 ± 0.004)
1.27
(0.050)
BSC
0.216 ± 0.038
(0.0085 ± 0.0015)
0.71
(0.028)MIN.
0.4 ± 0.05
(0.016 ± 0.002)
3.6 ± 0.1*
(0.142 ± 0.004)
DIMENSIONS IN MILLIMETERS (INCHES)
* MAXIMUM MOLD FLASH ON EACH SIDE IS 0.15 mm (0.006)
NOTE: FLOATING LEAD PROTRUSION IS 0.15 mm (6 mils) MAX.
7° MAX.
MAX. LEAD COPLANARITY
= 0.102 (0.004)
8.27
(0.325)
2.0
(0.080)
2.5
(0.10)
1.3
(0.05)
0.64
(0.025)
4.4
(0.17)
Regulatory Information
The HCPL-M600, HCPL-M601 and HCPL-M611 are approved by the following organizations:
IEC/EN/DIN EN 60747-5-5 (Option 060 only)
for HCPL-M601 and HCPL-M611
UL
Approval under UL 1577, component recognition pro-
gram up to VISO = 3750 VRMS.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
4
Insulation and Safety Related Specifications
Parameter Symbol Value Units Conditions
Minimum External Air Gap
(External Clearance)
L(101) 5 mm Measured from input terminals to output terminals,
shortest distance through air.
Minimum External
Tracking (External Creepage)
L(102) 5 mm Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 mm Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Description Symbol Characteristic Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage d 150 Vrms
for rated mains voltage d 300 Vrms
I – IV
I – III
Climatic Classification 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage VIORM 560 Vpeak
Input to Output Test Voltage, Method b*
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
VPR 1050 Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.5=VPR, Type and Sample Test, tm=60 sec,
Partial discharge < 5 pC
VPR 840 Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini =10 sec)
VIOTM 6000 Vpeak
Safety-limiting values – maximum values allowed in the event
of a failure.
Case Temperature
Input Current**
Output Power**
TS
IS, INPUT
PS, OUTPUT
150
150
600
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V RS>109:
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of PS and IS on ambient temperature.
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Input Current, Low Level IFL* 0 250 μA
Input Current, High Level IFH** 5 15 mA
Supply Voltage, Output VCC 4.5 5.5 V
Fan Out (RL = 1 kΩ) N 5 TTL Loads
Output Pull-Up Resistor RL330 4,000 Ω
Operating Temperature TA-40 85 °C
* The off condition can also be guaranteed by ensuring that VF(off) ≤ 0.8 volts.
** The initial switching threshold is 5mA or less. It is recommended that 6.3mA to 10mA be used for best performance and to permit at least a
20% LED degradation guardband.
5
Absolute Maximum Ratings
(No Derating Required up to 85°C)
Parameter Abs. Max.
Storage Temperature -55°C to +125°C
Operating Temperature -40°C to +85°C
Forward Input Current - IF (see Note 2) 20 mA
Reverse Input Voltage - VR 5 V
Supply Voltage - VCC (1 Minute Maximum) 7 V
Output Collector Current - IO 50 mA
Output Collector Power Dissipation 85 mW
Output Collector Voltage - VO
(Selection for higher output voltages up to 20 V is available)
7 V
Infrared and Vapor Phase Reflow Temperature see below
Solder Reflow Thermal Profile
Recommended Pb-Free IR Profile
Note: Non-halide flux should be used.
Note: Non-halide flux should be used.
0
TIME (SECONDS)
TEMPERATURE (°C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160°C
140°C
150°C
PEAK
TEMP.
245°C
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
SOLDERING
TIME
200°C
PREHEATING TIME
150°C, 90 + 30 SEC.
2.5°C ± 0.5°C/SEC.
3°C + 1°C/–0.5°C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3°C + 1°C/–0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
217 °C
RAMP-DOWN
6 °C/SEC. MAX.
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
260 +0/-5 °C
t 25 °C to PEAK
60 to 150 SEC.
20-40 SEC.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
tp
ts
PREHEAT
60 to 180 SEC.
tL
TL
Tsmax
Tsmin
25
Tp
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25 °C to PEAK
TEMPERATURE = 8 MINUTES MAX.
Tsmax = 200 °C, Tsmin = 150 °C
6
Insulation Related Specifications
Parameter Symbol Value Units Conditions
Min. External Air Gap L(IO1) ≥5 mm Measured from input terminals
(Clearance) to output terminals
Min. External Tracking Path L(IO2) ≥5 mm Measured from input terminals
(Creepage) to output terminals
Min. Internal Plastic Gap 0.08 mm Through insulation distance
(Clearance) conductor to conductor
Tracking Resistance CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group (per DIN VDE 0109) IIIa Material Group DIN VDE 0109
Electrical Specifications
Over recommended temperature (TA = -40°C to 85°C) unless otherwise specified. (See note 1.)
Parameter Symbol Min. Typ.* Max. Units Test Conditions Fig. Note
Input Threshold ITH 2 5 mA VCC = 5.5 V, IO ≥13 mA, 13
Current VO = 0.6 V
High Level Output IOH 5.5 100 μA VCC = 5.5 V, VO = 5.5 V 1
Current IF = 250 μA
Low Level Output VOL 0.4 0.6 V VCC = 5.5 V, IF = 5 mA, 2, 4,
Voltage IOL (Sinking) = 13 mA 5, 13
High Level Supply ICCH 4 7.5 mA VCC = 5.5 V, IF = 0 mA,
Current
Low Level Supply ICCL 6 10.5 mA VCC = 5.5 V, IF = 10 mA,
Current
Input Forward V
F 1.4 1.75 V T
A = 25°C, IF=10 mA 3
Voltage 1.5
1.3 1.85 IF = 10 mA
Input Reverse BVR 5 IR = 10 μA
Breakdown Voltage
Input Capacitance CIN 60 pF VF = 0V, f = 1 MHz
Input Diode VF/∆T
A -1.6 mV/°C IF = 10 mA 12
Temperature
Coefficient
Input-Output VISO 3750 VRMS RH ≤ 50%, t = 1 min. 3, 4
Insulation
Resistance RI-O 1012 Ω VI-O = 500 V 3
(Input-Output)
Capacitance CI-O 0.6 pF f = 1 MHz 3
(Input-Output)
*All typicals at TA = 25°C, VCC = 5 V.
7
Notes:
1. Bypassing of the power supply line is required with a 0.1 μF ceramic disc capacitor adjacent to each optocoupler. The total lead length be-
tween both ends of the capacitor and the isolator pins should not exceed 10 mm.
2. Peaking circuits may produce transient input currents up to 50 mA, 50 ns maximum pulse width, provided average current does not exceed
20 mA.
3. Device considered a two terminal device: pins 1 and 3 shorted together, and pins 4, 5 and 6 shorted together.
4. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 4500 VRMS for 1 second (Leakage detec-
tion current limit, II-O ≤ 5 μA).
5. The tPLH propagation delay is measured from 3.75 mA point on the falling edge of the input pulse to the 1.5 V point on the rising edge of the
output pulse.
6. The tPHL propagation delay is measured from 3.75 mA point on the rising edge of the input pulse to the 1.5 V point on the falling edge of the
output pulse.
7. CMH is the maximum tolerable rate of rise of the common mode voltage to assure that the output will remain in a high logic state (i.e., V
OUT >
2.0 V).
8. CML is the maximum tolerable rate of fall of the common mode voltage to assure that the output will remain in a low logic state (i.e., VOUT > 0.8
V).
9. For sinusoidal voltages, (|dVCM|/dt)max = SfCMVCM(p-p).
10. See application section; “Propagation Delay, Pulse-Width Distortion and Propagation Delay Skew” for more information.
11. tPSK is equal to the worst case differ ence in tPHL and/or tPLH that will be seen between units at any given temperature within the worst case
operating condition range.
Switching Specifications
Over recommended temperature (TA = -40°C to 85°C), VCC = 5 V, IF = 7.5 mA unless otherwise specified.
Device
Parameter Symbol HCPL- Min. Typ.* Max. Unit Test Conditions Fig. Note
Propagation tPLH 20 48 75 ns TA = 25°C RL = 350 Ω 6, 7 5
Delay Time
to High 100 CL = 15 pF 8
Output Level
Propagation tPHL 25 50 75 TA = 25°C 6, 7 6
Delay Time
to Low 100 8
Output Level
Propagation tPSK 40 10,
Delay Skew 11
Pulse Width |tPHL - tPLH| 3.5 35 9 10
Distortion
Output Rise trise 24
Time 10
(10%-90%)
Output Fall tfall 10
Time 10
(10%-90%)
Common |CMH| M600 10,000 V/μs VCM = 10 V VO(min) = 2 V 11 7, 9
M601 5,000 10,000 VCM = 50 V
M611 10,000 15,000 VCM = 1000 V
Common |CMH| M600 10,000 VCM = 10 V VO(max) = 0.8 V 11 8, 9
M601 5,000 10,000 VCM = 50 V
M611 10,000 15,000 VCM = 1000 V
*All typicals at TA = 25°C, VCC = 5 V.
Mode Transient
Immunity at High
Output Level
Mode Transient
Immunity at Low
Output Level
RL = 350 Ω
IF = 7.5 mA
TA = 25°C
RL = 350 Ω
IF = 0 mA
TA = 25°C
8
Figure 5. Low Level Output Current vs. Temperature.
Figure 4. Output Voltage vs. Forward Input current.
Figure 1. High Level Output Current vs. Temperature. Figure 2. Low Level Output Voltage vs. Temperature. Figure 3. Input Diode Forward Characteristic.
Figure 6. Test Circuit for tPHL and tPLH.
IOH – HIGH LEVEL OUTPUT CURRENT – μA
-60
0
TA – TEMPERATURE – °C
100
10
15
-20
5
20
VCC = 5.5 V
VO = 5.5 V
IF = 250 μA
60
-40 0 40 80
V
CC
= 5.5 V
I
F
= 5.0 mA
0.5
0.4
-60 -20 20 60 100
T
A
– TEMPERATURE – °C
0.3
80400-40
0.1
V
OL
– LOW LEVEL OUTPUT VOLTAGE – V
0.2
I
O
= 16 mA
I
O
= 12.8 mA
I
O
= 9.6 mA
I
O
= 6.4 mA
V
F
– FORWARD VOLTAGE – VOLTS
10
0.1
0.01
1.10 1.20 1.30 1.40
I
F
– FORWARD CURRENT – mA
1.601.50
1.0
0.001
100
I
F
V
F
+
T
A
= 25°C
1
6
2
3
4
5
123456
I
F
– FORWARD INPUT CURRENT – mA
R
L
= 350 Ω
R
L
= 1 KΩ
R
L
= 4 KΩ
00
V
CC
= 5 V
T
A
= 25 °C
V
O
– OUTPUT VOLTAGE – V
I
OL
– LOW LEVEL OUTPUT CURRENT – mA
-60
0
T
A
– TEMPERATURE – °C
100
60
80
-20
20
20
V
CC
= 5.0 V
V
OL
= 0.6 V
60-40 0 40 80
40
I
F
= 10 mA, 15 mA
I
F
= 5.0 mA
OUTPUT V
O
MONITORING
NODE
1.5 V
t
PLH
t
PHL
I
F
INPUT
V
O
OUTPUT
I
F
= 7.5 mA
I
F
= 3.75 mA
+5 V
I
F
R
L
R
M
0.1μF
BYPASS
*C
L
*C
L
IS APPROXIMATELY 15 pF WHICH INCLUDES
PROBE AND STRAY WIRING CAPACITANCE.
INPUT
MONITORING
NODE
PULSE GEN.
Z
O
= 50 Ω
t
f
= t
r
= 5 ns
V
CC
GND
1
3
6
5
4
9
Figure 12. Temperature Coefficient for Forward Voltage
vs. Input Current.
Figure 10. Rise and Fall Time vs. Temperature.
Figure 9. Pulse Width Distortion vs. Temperature.Figure 8. Propagation Delay vs. Pulse Input Current.Figure 7. Propagation Delay vs. Temperature.
Figure 11. Test Circuit for Common Mode Transient Immunity and Typical Waveforms.
V
CC
= 5.0 V
I
F
= 7.5 mA
100
80
-60 -20 20 60 100
T
A
– TEMPERATURE – °C
60
80400-40
0
t
P
– PROPAGATION DELAY – ns
40
20
t
PLH
, R
L
= 4 KΩ
t
PLH
, R
L
= 1 KΩ
t
PLH
, R
L
= 350 Ω
t
PHL
, R
L
= 350 Ω
1 KΩ
4 KΩ
VCC = 5.0 V
TA = 25°C
105
90
5913
IF – PULSE INPUT CURRENT – mA
75
15117
30
tP – PROPAGATION DELAY – ns
60
45
tPLH , RL = 4 KΩ
tPLH , RL = 1 KΩ
tPLH , RL = 350 Ω
tPHL , RL = 350 Ω
1 KΩ
4 KΩ
V
CC
= 5.0 V
I
F
= 7.5 mA
40
30
-20 20 60 100
T
A
– TEMPERATURE – °C
20
80400-40
PWD – PULSE WIDTH DISTORTION – ns
10
R
L
= 350 kΩ
R
L
= 1 kΩ
R
L
= 4 kΩ
0
-60
-10
tr, tf – RISE, FALL TIME – ns
-60
0
TA – TEMPERATURE – °C
100
300
-20
40
20 60-40 0 40 80
60
290
20
VCC = 5.0 V
IF = 7.5 mA
RL = 4 kΩ
RL = 1 kΩ
RL = 350 Ω, 1 kΩ, 4 kΩ
tRISE
tFALL
RL = 350 Ω
dVF/
dT
– FORWARD VOLTAGE
TEMPERATURE COEFFICIENT – mV/°C
0.1 1 10 100
I
F
– PULSE INPUT CURRENT – mA
-1.4
-2.2
-2.0
-1.8
-1.6
-1.2
-2.4
V
O
0.5 V
V
O
(MIN.)
5 V
0 V
SWITCH AT A: I
F
= 0 mA
SWITCH AT B: I
F
= 7.5 mA
V
CM
CM
H
CM
L
V
O
(MAX.)
V
CM
(PEAK)
V
O
+5 V
0.1 μF
BYPASS
+_
350 Ω
V
FF
1
3
6
5
4
B
AOUTPUT V
O
MONITORING
NODE
IF
PULSE
GENERATOR
Z
O
= 50 Ω
V
CC
GND
Propagation Delay,
Pulse-Width Distortion and Propagation Delay Skew
Propagation delay is a figure of merit which describes
how quickly a logic signal propagates through a sys-
tem. The propaga tion delay from low to high (tPLH) is the
amount of time required for an input signal to propagate
to the output, causing the output to change from low to
high. Similarly, the propagation delay from high to low
(tPHL) is the amount of time required for the input sig-
nal to propagate to the output, causing the output to
change from high to low (see Figure 7).
Pulse-width distortion (PWD) results when tPLH and tPHL
differ in value. PWD is defined as the difference between
tPLH and tPHL and often determines the maxi mum data
rate capability of a transmission system. PWD can be
expressed in percent by dividing the PWD (in ns) by the
minimum pulse width (in ns) being transmitted. Typi-
cally, PWD on the order of 20-30% of the minimum pulse
width is tolerable; the exact figure depends on the par-
ticular appli cation (RS232, RS422, T-1, etc.).
Propagation delay skew, tPSK, is an important param-
eter to consider in parallel data appli cations where
synchroniza tion of signals on parallel data lines is a con-
cern. If the parallel data is being sent through a group
of optocouplers, differ ences in propagation delays will
cause the data to arrive at the outputs of the optocou-
plers at different times. If this difference in propagation
delays is large enough, it will determine the maximum
rate at which parallel data can be sent through the op-
tocouplers.
Propagation delay skew is defined as the difference be-
tween the minimum and maximum propagation delays,
either tPLH or tPHL, for any given group of optocouplers
which are operating under the same conditions (i.e., the
same drive current, supply voltage, output load, and op-
erating tempera ture). As illustrated in Figure 15, if the in-
puts of a group of optocouplers are switched either ON
or OFF at the same time, tPSK is the difference between
the shortest propagation delay, either tPLH or tPHL, and
the longest propaga tion delay, either tPLH or tPHL.
As mentioned earlier, tPSK can determine the maximum
parallel data transmission rate. Figure 11 is the timing
diagram of a typical parallel data application with both
the clock and the data lines being sent through opto-
couplers. The figure shows data and clock signals at the
inputs and outputs of the optocouplers. To obtain the
maximum data transmission rate, both edges of the
clock signal are being used to clock the data; if only one
edge were used, the clock signal would need to be twice
as fast.
Propagation delay skew represents the uncertainty of
where an edge might be after being sent through an op-
tocoupler. Figure 16 shows that there will be uncertainty
in both the data and the clock lines. It is important that
these two areas of uncertainty not overlap, otherwise
the clock signal might arrive before all of the data out-
puts have settled, or some of the data outputs may start
to change before the clock signal has arrived. From these
considerations, the absolute minimum pulse width that
can be sent through optocouplers in a parallel applica-
tion is twice tPSK. A cautious design should use a slightly
longer pulse width to ensure that any additional uncer-
tainty in the rest of the circuit does not cause a prob-
lem.
The tPSK specified optocouplers offer the advantages of
guaranteed specifications for propagation delays, pulse-
width distortion and propagation delay skew over the
recommended temperature, and input current, and
power supply ranges.
Figure 15. Illustration of Propagation Delay Skew
– tPSK.
Figure 13. Input Threshold Current vs. Temperature. Figure 14. Recommended TTL/LSTTL to TTL/LSTTL Interface Circuit.
Figure 16. Parallel Data Transmission Example.
I
TH
– INPUT THRESHOLD CURRENT – mA
-60
0
T
A
– TEMPERATURE – °C
100
4
5
-20
2
20 60-40 0 40 80
3
V
CC
= 5.0 V
V
O
= 0.6 V
1R
L
= 4 kΩ
R
L
= 1 kΩ
R
L
= 350 Ω
6
V
CC
1
GND 1
470
SHIELD
* DIODE D1 (1N916 OR EQUIVALENT) IS NOT REQUIRED
FOR UNITS WITH OPEN COLLECTOR OUTPUT.
6
5
4
390 Ω
0.1 μF
BYPASS
GND 2
V
CC
2
1
3
*D1
5 V
5 V
I
F
V
F
2
1
50%
1.5 V
I
F
V
O
50%I
F
V
O
t
PSK
1.5 V
DATA
t
PSK
INPUTS
CLOCK
DATA
OUTPUTS
CLOCK
t
PSK
For product information and a complete list of distributors, please go to our website: www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change. Copyright © 2005-2010 Avago Technologies. All rights reserved. Obsoletes AV01-0562EN
AV02-0941EN - February 23, 2010