Notice
It is Microsemi’s policy to improve its products as new
technology, components, software, and firmware
become available. Microsemi, therefore, reserves the
right to change specifications without prior notice.
Technical Support
If you encounter problems when installing or using this
product, please consult the Microsemi website at:
http://www.Microsemi.com
For technical support, call: +972-9-775-5123
In the USA: 1-877-480-2323
Email: sales.support@microsemi.com
Recycling and Disposal
Disposal instructions for old products. The WEEE
(Waste Electrical and Electronic Equipment) national
environmental initiatives has been put in place to
ensure that products are recycled using best
available treatment, and recovery and recycling
techniques to ensure human health and high
environmental protection. Your product is designed
and manufactured with high quality materials and
components which can be recycled and reused. Do
not dispose of your old product in your general
household waste bin. Inform yourself about the local
separate collection system for electrical and
electronic products marked by this symbol:
Use one of the following disposal options :
1. Dispose of the complete product (including its
cables, plugs and accessories) in the designated
WEEE collection facility.
2. If you purchased a replacement product, return
your older product (including all components) back to
the retailer. The retailer should accept it as required
by the national WEEE legislation.
Microsemi Corp.
Ordering information:
Part number: PD-9001GR/AC
Product Family Name: Microsemi 9001GR
Description: 1-Port 802.3at + Legacy Gigabit PoE Midspan
Part number: PD-9001GR/AT/AC
Product Family Name: Microsemi 9001GR
Description: 1-Port 802.3at Gigabit PoE Midspan
Document P/N : 06-0473-056, Rev. C00
Safety Information
Important Safety Information
Connect the PD-9001GR to PoE networks only, without
routing to the outside plant.
Only qualified personnel can install or remove the
PD-9001GR.
AC Power Cord Set:
The power cord must have regulatory agency approval for
the specific country in which it is used (for example UL,
CSA, VDE, etc.).
The power cord must be a three-conductor type (two
current carrying conductors; one ground conductor)
terminated on one end by an IEC 60320 appliance coupler
(for connection to the PD-9001GR), and on the other end
by a plug containing a ground (earthing) contact.
The power cord must be rated for a minimum of 250 VAC
RMS operation, with a minimum rated current capacity of
5 amps (or a minimum wire gauge of 18 AWG (0.75 mm2).
: A PD-9001GR installed in Australia requires power cords
with a minimum wire gauge of 16 AWG (1.0 mm2).
: The PD-9001GR "Data In" and "Data & Power Out" ports
are shielded RJ45 data sockets. They cannot be used as Plain
Old Telephone Service (POTS) telephone sockets. Connect RJ45
data connectors only to these sockets.
The AC wall socket-outlet must be near the PD-9001GR
and easily accessible. You can remove AC power from
the PD-9001GR by disconnecting the AC power cord
from either the wall socket-outlet or the PD-9001GR
appliance coupler.
The PD-9001GR Data In and Data & Power Out
interfaces are qualified as Safety Extra-Low Voltage
(SELV) circuits according to IEC 60950-1. Connect
these interfaces only to SELV interfaces on other
equipment.
WARNINGS!
Connect the PD-9001GR only to the IP device with
which it was bought. Using the PD-9001GR with other IP
devices can cause damage to the IP device.
Read the installation instructions before connecting the
PD-9001GR to its power source.
Follow basic electricity safety measures whenever
connecting the PD-9001GR to its power source.
A voltage mismatch can cause equipment damage and
may pose a fire hazard. If the voltage indicated on the
label is different from the power outlet voltage, do not
connect the PD-9001GR to that power outlet.
Troubleshooting
Symptom
PD-
9001GR
does not
power up
The PD
does not
operate
The end
device
operates,
but there
is no data
link
Port Connectivity
Indication
Ethernet
Cat . 5 Cable
Terminal
Figure 1: Connecting the PD-9001GR
Indicators
Port LED
Indicated Behavior
Yellow On
Power is on (power is active)
Green On
A remote terminal is connected
Green Blinking
Overload state or short-circuit
Specifications
Environmental Specifications
Mode
Temperature
Humidity
Operating
0° to +40° C
32° to +104° F
10 to 90%; (no
condensation
allowed)
Storage
-20° to +70° C
-4° to +158° F
10 to 90%; (no
condensation
allowed)
Electrical Specifications
Input Voltage
100 - 240 VAC (50/60 Hz)
Maximal Input Current
0.67 Ampere
Guaranteed Output power
30 Watts
Nominal Output Voltage
55 VDC
Ethernet Interface
Input (Data In): Ethernet
10/100/1000Base-T
RJ45 female socket
Output (Data & Power
Out): Ethernet
10/100/1000Base-T, plus
55 VDC
RJ45 female socket, with
DC voltage on wire pairs,
4-5 (+) & 7-8 (-).
Functions and Features
The PD-9001GR Power over Ethernet (PoE) Single Port Midspan
offers a compact and cost effective power
solution for IP phones, WLAN access points, network cameras
and other IP terminal installations.
The PD-9001GR converts AC power to 55VDC power is then
provided over the Ethernet cable.
The PD-9001GR supports up to Mbps pass through
data rates. The single port PD-9001GR can be powered via
universal AC input.
PD-9001GR EMC Compliance:
FCC Part 15 class B and EN55022 class B
EN55024
VCCI
PD-9001GR Safety Compliance:
UL/cUL per 60950-1 2nd Ed.
GS mark
Preliminary Steps
Apply AC power to the PD-9001GR, using an
operational AC cable with an appropriate ground
connection.
Connect an output Ethernet cable to the Data & Power
Out port.
Verify that a power ready Ethernet compatible device is
connected.
WARNING
Do not use cross over cable between the PD-9001GR output
port and the load device
Installation
The PD-9001GR can be placed on a desktop.
: Before placing the PD-9001GR:
Do not to cover PD-9001GR or block the airflow to the
PoE with any foreign objects. Keep the PD-9001GR
away from excessive heat and humidity and free from
vibration and dust.
Ensure that the cable length from Ethernet network
source to the terminal does not exceed 100 meters
(330 feet). The PoE is not a repeater and does not
amplify the Ethernet data signal.
Use a splitter if desired; ensure that the splitter is
connected close to the terminal and not on the
PD-9001GR!
No “on-off” switch exists; simply plug the PD-9001GR
into an AC power source.
Installing the Unit
Refer to Figure 1.
1. Using a standard power cord, connect the PD-9001GR to an
AC outlet (100 - 240 VAC),
2. Connect the Data In jack (input) to the remote Ethernet
network switch's Patch panel and the Data & Power Out jack
(output) to the terminal.