82723 Paired - Double-Pair Cable
For more information please
call
1-800-Belden1
See Put-ups and Colors
Description:
22 AWG stranded (7x30) TC conductors, plenum, FEP insulation, twisted pairs, individually shielded w/Beldfoil® (100% coverage), 22
AWG stranded TC drain wire, Flamarrest® jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs 2
Total Number of Conductors 4
AWG 22
Stranding 7x30
Conductor Material TC - Tinned Copper
INSULATION:
Insulation Material FEP - Fluorinated Ethylene Propylene
Lay Length 1.5 in.
Twists/ft. 8
Pair Color Code Chart :
Number Color
1 Red & Black Number Color
2 Green & White
INNER SHIELD:
Inner Shield Material Trade Name Beldfoil® (Z-Fold®)
Inner Shield Type Tape
Inner Shield Material Aluminum Foil-Polyester Tape
Inner Shield % Coverage 100 %
Inner Shield Drain Wire AWG 24
Inner Shield Drain Wire Stranding 7x32
Inner Shield Drain Wire Conductor Material TC - Tinned Copper
OUTER SHIELD:
Outer Shield Material Unshielded
OUTER JACKET:
Outer Jacket Material Trade Name Flamarrest®
Page 1 of
3
82723 Paired - Double-Pair Cable
Outer Jacket Material LS PVC - Low Smoke Polyvinyl Chloride
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter .153 in.
MECHANICAL CHARACTERISTICS:
Operating Temperature Range 0°C To +75°C
Bulk Cable Weight 17.5 lbs/1000 ft.
Max. Recommended Pulling Tension 46 lbs.
Min. Bend Radius (Install) 1.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification CMP
CEC/C(UL) Specification CMP
EU CE Mark (Y/N) Yes
EU RoHS Compliant (Y/N) Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
FLAME TEST:
UL Flame Test NFPA 262
C(UL) Flame Test FT6
PLENUM/NON-PLENUM:
Plenum (Y/N) Y
Non-Plenum Number 8723
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance 36 Ohms
Nom. Capacitance Conductor to Conductor @ 1 KHz 43 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 75 pF/ft
Nominal Velocity of Propagation 62 %
Nom. Conductor DC Resistance @ 20 Deg. C 14.7 Ohms/1000 ft
Nom. Inner Shield DC Resistance 15 Ohms/1000 ft
Max. Operating Voltage - UL 300 V RMS
Max. Recommended Current 2.3 Amps per conductor @25°C
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
82723 8771000 2 PR #22 FEP FS
FLRST 1000 19 NATURAL
C
82723 877U1000 2 PR #22 FEP FS
FLRST U1000 20 NATURAL
Page 2 of
3
82723 Paired - Double-Pair Cable
82723 877U2000 2 PR #22 FEP FS
FLRST U2000 40 NATURAL
82723 877U500 2 PR #22 FEP FS
FLRST U500 10.5 NATURAL
C = CRATE REEL PUT-UP.
Revision Number: 1 Revision Date: 07-27-2005
© 2005 Belden Wire & Cable Company
All Rights Reserved.
Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication,
information and specifications described herein are subject to error or omission and to change without notice, and the listing of such
information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California
Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS
(Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our
Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR
(Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as
reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its
publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any
other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality
specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of
legislation and regulations based on their individual usage of the product.
Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended
by directive 93/68/EEC.
Page 3 of
3