DATA SHEET AAT4684 Over-Voltage Protection Switch General Description Features The AAT4684 OVPSwitchTM is a member of Skyworks' Application Specific Power MOSFETTM (ASPMTM) product family. It is a P-channel MOSFET power switch with precise over-voltage protection control, designed to protect low-voltage systems against high-voltage faults up to +28V. If the input voltage exceeds the programmed over-voltage threshold, the P-channel MOSFET switch will be turned off to prevent damage to the output load circuits. The AAT4684 is available with an internally programmed over-voltage trip point or as an adjustable version programmed by two external resistors. * * * * The AAT4684 also includes an under-voltage lockout (UVLO) protection circuit, which will put the device into sleep mode at low input voltages only consuming < 1A of current. The AAT4684 is offered in a small Pb-free, 12-pin TSOPJW package and is specified for operation over the -40C to +85C ambient temperature range. * * * * * Over-Voltage Protection Up to +28V Fixed or Adjustable Over-Voltage Protection Threshold 3V Under-Voltage Lockout Threshold Fast OVP Response: 1s (Max) to Over-Voltage Transient Low Operation Quiescent Current 30A Typical 1A Max in Shutdown (Disabled) 100m Typical (130m max) RDS(ON) at 4.5V 1.8A Maximum Continuous Current Temperature Range: -40C to 85C Available in TSOPJW-12 Package Applications * * * * * * Cell Phones Digital Still Cameras GPS MP3 Players Personal Data Assistants (PDAs) USB Hot Swap/Live Insertion Device Typical Application (Adjustable Version) VIO +5V VIN 3V - 28V IN FLT Fault Flag OUT VOUT AAT4684 OVP 1F EN GND Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 1 DATA SHEET AAT4684 Over-Voltage Protection Switch Pin Descriptions Pin # Fixed Adj. Symbol 1, 2, 9, 11, 12 1, 2, 9, 12 N/C 3 3 FLT 4 4 EN 5, 6 7, 8 10 n/a 5, 6 7, 8 10 11 OUT IN GND OVP Function Not connected. Over-voltage fault reporting output pin. FLT goes low when input voltage exceeds the over-voltage threshold. An external pull up resistor to VIO (6.5V max) should be added. Enable pin, active low. An internal pull-down resistor is connected on this pin. Connect to Ground for normal operation. Connect to high (6.5V max) to shut down the device when it draws less than 1A of current. Output pin. Connect a 0.1F~47F capacitor from OUT to GND. Power input pin. Connect 1F capacitor from IN to GND. Ground connection pin. Over-voltage protection threshold input pin (Adjustable version only). Pin Configuration TSOPJW-12 Fixed Version (Top View) 2 TSOPJW-12 Adjustable Version (Top View) N/C 1 12 N/C N/C 1 12 N/C N/C 2 11 N/C N/C 2 11 OVP FLT 3 10 GND FLT 3 10 GND EN 4 9 N/C EN 4 9 N/C OUT 5 8 IN OUT 5 8 IN OUT 6 7 IN OUT 6 7 IN Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 DATA SHEET AAT4684 Over-Voltage Protection Switch Absolute Maximum Ratings1 Symbol VIN VOVP VFLT, VEN VOUT IMAX TJ TSTG Description IN to GND OVP to GND FLT, EN to GND OUT to GND Maximum Continuous Switch Current Operating Junction Temperature Range Storage Temperature Value Units -0.3 to 30 -0.3 to 6.5 -0.3 to 6.5 VIN + 0.3 1.8 -40 to 150 -65 to 150 V V V V A C C Value Units 160 625 C/W mW Thermal Characteristics Symbol JA PD Description Maximum Thermal Resistance2 Maximum Power Dissipation2, 3 1. Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation at conditions other than the operating conditions specified is not implied. Only one Absolute Maximum Rating should be applied at any one time. 2. Mounted on a FR4 board. 3. Derate 6.25mW/C above 25C. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 3 DATA SHEET AAT4684 Over-Voltage Protection Switch Electrical Characteristics1 VIN = 5V, TA = -40C to 85C unless otherwise noted. Typical values are at TA = 25C. Symbol Description Conditions VIN Normal Operation Voltage Range IQ Operation Quiescent Current VIN = 5V, EN = 0V, IOUT = 0 Shutdown Supply Current Under-Voltage Lockout Threshold Under-Voltage Lockout Hysteresis EN = IN, VIN = 5.5V, VOUT = 0 Rising Edge Over-Voltage Lockout Threshold, OVP Pin Over-Voltage Lockout Threshold Hysteresis, OVP Pin Rising Edge ISD(OFF) VUVLO VUVLO_HYS Adjustable VOVP_TH VOVP_HYS Fixed VIN_OVP_TH Input Over-Voltage Lockout Threshold, IN Pin Input Over-Voltage Lockout Threshold Hysteresis, VIN_OVP_HYS IN Pin MOSFET Switch RDS(ON) PMOS On-Resistance ID(OFF) Switch Off-Leakage Logic VEN(L) EN Input Low Voltage VEN(H) EN Input High Voltage EN Input Leakage IEN FLTOL FLT Output Voltage Low FLTIOL FLT Output Leakage Current TBLK_FLT FLT Blanking Time TD_FLT FLT Assertion Delay Time from Over-Voltage (OV) TRESP_OV Over-Voltage Response Time TON Turn On Delay Time TR Turn On Rise Time TOFF Turn Off Delay Time TF Turn Off Fall Time Thermal Protection Shutdown Temperature TSHDN THYS Over-Temperature Shutdown Hysteresis Min Typ 3.0 30 3.0 0.1 1.084 Rising Edge IOUT = 1800mA, TA = 25C EN = VIN 1.1 20 Max Units 14 V 50 A 1 3.3 A V V 1.117 V mV 6.5 V 120 mV 100 130 1 m A 0.4 V V A V A ms s 1.6 VEN = 5.5V or 0V IFLT = 1mA From De-assertion of OV From Assertion of OV VIN = 5V, VOVP Rise to 1.13V from 1.07V in 1ns VIN = 5V; RO = 10; CO = 1F VIN = 5V; RO = 10; CO = 1F VIN = 5V; RO = 10; CO = 1F VIN = 5V; RO = 10; CO = 1F 0.5 5 10 1 2.0 0.4 1 15 0.7 s 10 1 6 20 ms ms ms s 120 25 C C 1. The AAT4684 is guaranteed to meet performance specifications over the -40 to 85C operating temperature range and is assured by design, characterization and correlation with statistical process controls. 4 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 DATA SHEET AAT4684 Over-Voltage Protection Switch Typical Characteristics Operation Quiescent Current vs. Supply Voltage Operation Quiescent Current vs. Temperature 40 45 Quiescent Current (A) Quiescent Current (A) 50 40 35 30 25 20 15 10 5 0 35 30 25 20 15 3 4 5 6 7 8 9 10 11 12 13 -40 14 -15 Supply Voltage (V) 1.8 1.2 0.6 0.0 8 10 12 14 16 18 20 22 24 26 28 Shutdown Supply Current (A) Shutdown Supply Current (A) 2.4 6 85 0.35 0.28 0.21 0.14 0.07 0.00 -40 -15 Supply Voltage (V) 10 35 60 85 Temperature (C) Switch Off Leakage Current vs. Supply Voltage PMOS On-Resistance vs. Temperature 160 0.014 0.012 On-Resistance (A) Switch Off Leakage Current (A) 60 Shutdown Supply Current vs. Temperature 3.0 4 35 Temperature (C) Shutdown Supply Current vs. Supply Voltage 2 10 0.010 0.008 0.006 0.004 0.002 0.000 2 4 6 8 10 12 14 16 18 20 Supply Voltage (V) 22 24 26 28 140 120 100 80 60 -40 -15 10 35 60 85 Temperature (C) Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 5 DATA SHEET AAT4684 Over-Voltage Protection Switch Typical Characteristics FLT Blanking Time vs. Temperature FLT Blanking Time (VIN = 5.0V) FLT Blanking Time (ms) 12 5.0V VOUT (1V/div) 11 4.3V 10 FLT (2V/div) 9 8 0V 1.15V OVP (100mV/div) 7 -40 -15 10 35 60 85 Temperature (C) Time (2ms/div) UVLO Threshold (V) 4.00 3.50 VIN Rising 3.00 VIN Falling 2.50 2.00 1.50 -40 -15 10 35 60 85 Temperature (C) Over-Voltage Response Time vs. Temperature Over-Voltage Response Time (ns) Undervoltage Lockout Threshold vs. Temperature 800 750 700 650 600 550 -40 -15 10 35 Temperature (C) Over-Voltage Lockout Threshold (Adjustable Version) vs. Temperature 1.12 1.11 VOVP_TH VOVP 1.10 1.09 VOVP_HYS 1.08 1.07 1.06 -40 -15 10 35 60 85 Temperature (C) 6 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 60 85 DATA SHEET AAT4684 Over-Voltage Protection Switch Typical Characteristics EN Input High Voltage vs. Supply Voltage EN Input Low Voltage vs. Supply Voltage 1.1 1.1 -40C 0.9 -40C 1.0 VEN(L) (V) VEN(H) (V) 1.0 25C 0.8 85C 0.7 25C 0.9 0.8 85C 0.7 0.6 0.6 3 4 5 6 7 8 9 10 11 12 13 14 3 Supply Voltage (V) 6 7 8 9 10 11 12 13 14 Turn On Delay Time (VIN = 5.0V, RO = 10 ) EN (2V/div) 5 Supply Voltage (V) Turn Off Delay Time (VIN = 5.0V, RO = 10W W) VOUT (2V/div) 4.84V VOUT (2V/div) 4 0V EN (2V/div) 0V 0V Time (2ms/div) Time (2ms/div) Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 7 DATA SHEET AAT4684 Over-Voltage Protection Switch Functional Block Diagram Fixed Option IN OVP EN Functional Description The AAT4684 provides up to 28V over-voltage protection when powering low-voltage systems such as cell phones, MP3, and PDAs or when charging Lithium-Ion batteries from a badly regulated supply. The AAT4684 is inserted between the power supply or charger source and the load to be protected. The AAT4684 IC consists of a low resistance P channel MOSFET, under-voltage lockout protection, over-voltage monitor, fast shut-down circuitry and a fault output flag. In normal operation the P channel MOSFET acts as a slew-rate controlled load switch, connecting and disconnecting the power supply from IN to OUT. A low resistance MOSFET is used as to minimize the voltage drop between the voltage source and the load and to reduce the power dissipation. When the voltage on the input 8 OUT OVP Sense and Control FLT GND exceeds the over-voltage protection trip voltage (internally set or externally by a voltage divider to the OVP pin), the device immediately turns off the internal P-channel FET, disconnecting the load from the abnormal input and preventing damage to any downstream components. Simultaneously, the fault flag is raised alerting the system to a problem. If an over-voltage condition is applied at the time of the device enable, then the switch will remain OFF. Under-Voltage Lockout (UVLO) The AAT4684 has a fixed 3.0V under-voltage lockout level (UVLO). When the input voltage is less than the UVLO level, the MOSFET is turned off. 100mV of hysteresis is included to ensure circuit stability. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 DATA SHEET AAT4684 Over-Voltage Protection Switch Over-Voltage Protection The AAT4684 adjustable version has a 1.1V 1.5% overvoltage trip threshold on the OVP pin. With a resistor divider on OVP pin from IN to GND, the over-voltage trip point can be adjusted anywhere within the input voltage range (see Table 1). Once the over-voltage trip level is triggered, the PMOS switch controller will shut off the PMOS in less than 1s. The AAT4684 fixed version is also available where the resistor divider is internally integrated with the input voltage trip point at 6.5V. The fixed version of AAT4684 does not have a connection to the internal OVP circuitry and the pin #11 is designed to be not connected. FLT Output The FLT output is an active-low open-drain fault (OV) reporting output. A pull-up resistor should be connected from FLT to the logic I/O voltage of the host system. FLT will be asserted immediately if an over-voltage fault occurs (only about a 1s inherited internal circuit delay). A 10ms blanking is applied to FLT signal prior to deassertion. Over-Temperature Protection (OTP) If the ambient temperature of the device exceeds TSHDN, the OVP switch is turned off, and the pin is driven low. The OVP switch will recover automatically when the junction temperature falls below TSHDN - 25C. EN Input EN is an active-low enable input. EN is driven low, connected to ground, or left floating for normal device operation. Taking the EN high turns off the MOSFET. In the case of an over-voltage or UVLO condition toggling the EN will not override the fault condition and the switch will remain off. Device Operation On initial power-up, if VIN < UVLO or if VOVP > VOVP_TH (1.1V), the PMOS is held off. If UVLO < VIN, VOVP < VOVP_TH, and EN is low, the device enters startup after a 10ms internal delay. Application Information Over-Voltage Protection The AAT4684 over-voltage protection circuit provides fast protection against transient voltage spikes and short duration spikes of high voltage from the power supply lines. AAT4684 can quickly disconnect the input supply from the load and not cause any damage to sensitive components In portable product applications, if the user removes the battery pack during charging, this action can create large transients and a high voltage spike can occur which can damage other electronic devices in the product such as the battery charger. A hot plug of the AC/DC wall adapter into the AC outlet can create and release a voltage spike from the transformer. As a result, some sensitive devices within the product can be damaged. With the AAT4684 placed between the power lines and the sensitive devices, the voltage spike can be kept away and the input supply disconnected from other devices in 0.7s. Figure 2 shows the response time of over-voltage protection from the test circuit (Figure 1). The input voltage is rapidly increased from 5V to 12V by a voltage surge or voltage spike. The voltage at the OVP pin is also increased until the trip point is triggered. At this point, the FLT pin is pulled low and the output voltage starts to fall. Figure 3 shows a zoom-in scope capture of the OVP response time; the output is disconnected from the input in as little as 700ns. Adjustable Version Over-Voltage Protection Resistors The over-voltage protection threshold is programmed with two resistors, R1 and R2. To limit the current going through the external resistor string while maintaining good noise immunity, use smaller resistor values, such as 10K for R2. Using a larger value will further reduce the system current, but will also increase the impedance of the OVP node, making it more sensitive to external noise and interference. VOVP = VOVP_TH * 1 + R1 R2 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 9 DATA SHEET AAT4684 Over-Voltage Protection Switch A suggested value for R2 is 110K and R1 can be calculated from the following formula once the over-voltage protection voltage is set. R1 = R 2 * VOVP -1 VOVP_TH Table 1 summarizes resistor values for various overvoltage settings. Use 1% tolerance metal film resistors for programming the desired OVP setting. R2 (K) R1 (K) VOVP Setting (V) 110 110 110 110 110 110 110 110 110 110 487 536 787 1050 1300 1540 1780 2050 2320 2550 6.0 6.5 9.0 11.5 14.0 16.5 19.0 21.5 24.0 26.5 Table 1: Recommended OVP Setting for AAT4684 Adjustable Version1. SCOPE +12V LOAD AAT4684 10 Vin 1 2 3 4 8 7 6 5 gnd Vout GND +5V OVP Fault Figure 1: Over-Voltage Protection Response Time Test Circuit. 12V VIN (5V/div) OVP (200mV/div) Output Load = 10 COUT = 1F OVP (50mV/div) OVP Trip Point (1.1V) VOUT (5V/div) 1.23V 1.03V 0.7s VOUT (100mV/div) Output Load = 10 No COUT 5V FLT (2V/div) FLT (2V/div) Time (200s/div) Figure 2: Typical Over-Voltage Response Time. Time (500ns/div) Figure 3: Typical Over-Voltage Response Time [zoom in]. 1. Mimimum OVP voltage setting = 5V. 10 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 DATA SHEET AAT4684 Over-Voltage Protection Switch Input Capacitor A 1F or larger capacitor is typically recommended for CIN. CIN should be located as close to the device VIN pin as practically possible. Ceramic, tantalum, or aluminum electrolytic capacitors may be selected for CIN. There is no specific capacitor equivalent series resistance (ESR) requirement for CIN. However, for higher current operation, ceramic capacitors are recommended for CIN due to their inherent capability over tantalum capacitors to withstand input current surges from low impedance sources such as batteries in portable devices. Capacitors are typically manufactured in different voltage ratings. 16V, 25V, and 50V are good for OVP applications. If the maximum possible surge voltage is known, select capacitors with a voltage rating at least 5V higher than the maximum possible surge voltage. Otherwise, 50V rated capacitors are generally good for most OVP applications to prevent any surge voltage. Output Capacitor In order to insure stability while current limit is active, a small output capacitance of approximately 1F is required at the output. Likewise, with the output capacitor, there is no specific capacitor ESR requirement. If desired, COUT may be increased to accommodate any load transient condition. will assume the load switch is mounted on a printed circuit board utilizing the minimum recommended footprint as stated in the "Printed Circuit Board Layout Recommendations" section of this datasheet. At any given ambient temperature (TA), the maximum package power dissipation can be determined by the following equation: PD(MAX) = Constants for the AAT4684 are maximum junction temperature (TJ(MAX) = 125C) and package thermal resistance (JA = 160C/W). Worst-case conditions are calculated at the maximum operating temperature, TA = 85C. Typical conditions are calculated under normal ambient conditions where TA = 25C. At TA = 85C, PD(MAX) = 250mW. At TA = 25C, PD(MAX) = 625mW. The maximum continuous output current for the AAT4684 is a function of the package power dissipation and the RDS of the MOSFET at TJ(MAX). The maximum RDS of the MOSFET at TJ(MAX) is calculated by increasing the maximum room temperature. For maximum current, refer to the following equation: IOUT(MAX) = FAULT Flag A FAULT flag is provided to alert the system if the AAT4684's input voltage has passed the pre-programmed over-voltage trip point. Since the FAULT is open drain pin, it should be pulled up to input/output voltage rail and less than the maximum operating voltage of 6.5V. Thermal Considerations and High Output Current Applications The AAT4684 is designed to deliver a continuous output load current. The limiting characteristic for maximum safe operating output load current is package power dissipation. In order to obtain high operating currents, careful device layout and circuit operating conditions must be taken into account. The following discussions TJ(MAX) -TA JA PD(MAX) RDS Printed Circuit Board Layout Recommendations For proper thermal management and to take advantage of the low RDS(ON) of the AAT4684, certain circuit board layout rules should be followed: VIN and VOUT should be routed using wider than normal traces, and GND should be connected to a ground plane. To maximize package thermal dissipation and power handling capacity of the AAT4684 TSOPJW-12 package, the ground plane area connected to the ground pins should be made as large as possible. For best performance, CIN and COUT should be placed close to the package pins. Refer to Figures 3 and 4. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 11 DATA SHEET AAT4684 Over-Voltage Protection Switch Evaluation Board Schematic +5V DS1 Red LED U1 VIN R1 C1 1F R2 110k 8 7 1 2 11 9 TSOPJW-12 IN IN N/C N/C OVP N/C FLT N/C OUT OUT EN GND 3 12 5 6 4 10 R3 1.5K VOUT C2 1F AAT4684 JP1 Enable Adjustable version R1 (k) VOVP_SETTING (V) 487 536 787 1050 1300 1780 2320 6.0 6.5 9.0 11.5 14.0 19.0 24.0 Input Cap, C1 C1 1206 X7R 1F 50V GRM31MR71H105KA88 (C1 1206 X7R 2.2F 50V GRM31CR71H225KA88L) (C1 1210 X7R 4.7F 50V GRM32ER71H475KA88L) Output Cap, C2 for under 13V application, C2 0805 X7R 1F 16V GRM21BR71C105KA01 (for under 20V application, C2 0805 X7R 1F 25V GRM219R71E105KA88) For the fixed version, Open R1 and R2. Figure 3: AAT4684 Evaluation Board Schematic. Evaluation Board Layout Figure 4: AAT4684 Evaluation Board Component Side Layout. 12 Figure 5: AAT4684 Evaluation Board Solder Side Layout. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 DATA SHEET AAT4684 Over-Voltage Protection Switch Ordering Information Package OVP Trip Voltage Marking Part Number (Tape and Reel) TSOPJW-12 TSOPJW-12 Adjustable 6.5V YSXYY AAT4684ITP-T1 AAT4684ITP-6.5-T1 Skyworks GreenTM products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of GreenTM, document number SQ04-0074. Package Information TSOPJW-12 2.85 0.20 2.40 0.10 0.20 + 0.10 - 0.05 0.50 BSC 0.50 BSC 0.50 BSC 0.50 BSC 0.50 BSC 7 NOM 0.04 REF 0.055 0.045 0.15 0.05 + 0.10 1.00 - 0.065 0.9625 0.0375 3.00 0.10 4 4 0.45 0.15 0.010 2.75 0.25 All dimensions in millimeters. 1. XYY = assembly and date code. 2. Sample stock is generally held on part numbers listed in BOLD. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012 13 DATA SHEET AAT4684 Over-Voltage Protection Switch Copyright (c) 2012 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. ("Skyworks") products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and "Breakthrough Simplicity" are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. 14 Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201959A * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice. * May 16, 2012