Tubular Optical Sensors Technical Description The S5 series represent an economical, full-line family of 18 mm tubular photoelectric sensors. This broad-line family is available in straight or right angle tubular housings with all the following sensing modes supported: - Retroreflective Polarized retroreflective Diffuse scanner Fixed focus diffuse scanner - Fiber optics - Emitter/receiver The S5 versions operating from 10 to 30 Vdc have dual NPN/PNP output and light/ dark operation selection. These units are also shortcircuit and reverse polarity protected. The AC versions accept any voltage from 15 to 264 Vac and are supplied with Triac output. A red output LED indicator is standard in all models. The DC versions of the series are provided with a green stability LED to control alignment. S5 sensors are enclosed in a plastic casing, which meets protection class IP67. Electrical connection may be with a cable or using the standard M12 DC micro connector. The wide range of models available allow these sensors to be used in a variety of industrial applications requiring solutions for critical space and difficult access situations. An MEK 18 mm glass cover is available to protect the lens when used in the presence of corrosive substances. BOS S5 Features Applications - AC versions (15 to 264 Vac) - DC versions (10 to 30 Vdc) - Green stability LED - Light/dark selection - Sensitivity control - Straight or 90 optics - Connection via cable or M12 connector - Test input models - Fiber optic versions - Plastic casing - IP67 - M18x1 tubular plastic housing with IP67 rating - Automatic packaging machines - Presence detection, counting - Transport and conveyor lines - Robotics and FMS applications - Small object detection - Critical space situations 2 2.35 BOS-S5 DC, Selectable PNP/NPN and Light/Dark Operate BOS S5 Straight, Cable Out 14mm to 12m BOS S5 Straight, Connector 14mm to 12m M18x1 13 13 M18x1 22 sn LED Diffuse Fixed Focus Retroreflective Polarized Retroreflective Thru-Beam Fiber Optic, Plastic 80mm (3.1 in.) 100mm (4.0 in.) 300mm (11.8 in.), Potentiometer 350mm (13.8 in.), Potentiometer 14mm (0.55 in.) 15mm (0.6 in.) , Potentiometer 0.1 to 2m (.3 to 6.6 ft) 0.1 to 4m (.3 to 13 ft) 0.1 to 1.5m (.3 to 5 ft) Pol. Filter 0.1 to 2m (.3 to 6.6 ft) Pol. Filter 8m (26 ft), Receiver, Potentiometer 12m (39 ft), Receiver, Potentiometer 8m (26 ft), Sender 12m (39 ft), Sender Potentiometer Voltage supply Voltage drop, output Rated isolation voltage Rated output current Supply current (no load) Protections On/Off delay Switching frequency Output type Output function Sensitivity/Range adjustment Output function indication Ambient Light Protection Emitter light source Dimension Values With potentiometer: L = 65 mm X = 42 mm Without potentiometer: L = 55 mm X = 32 mm 2.36 Ambient operating temperature Storage temperature Degree of protection per IEC 529 Shock/vibration Relative Humidity Housing material Sensing face material Connection Recommended Connector 37.4 70.4 sn 8 37.4 22 70.4 Series Cable Out Sensing Range 8 Tubular Optical Sensors LED BOS S5-5-C10-30 BOS S5-5-C10-32 BOS S5-5-C35-30 BOS S5-5-D14-30 BOS S5-5-D15-30 BOS S5-5-C35-32 BOS S5-5-D14-32 BOS S5-5-D15-32 BOS S5-5-A4-30 BOS S5-5-A4-32 BOS S5-5-B3-30 BOS S5-5-B3-32 BLE S5-5-F12-30 BLE S5-5-F12-32 BLS S5-5-G12-00 BLS S5-5-G12-02 10 to 30 Vdc <1.5 V 75 Vdc 150 ma 30 ma Short circuit, polarity reversal 1 ms, 2 ms for thru-beam 500 Hz, 250 for thru-beam Wire option PNP/NPN Wire option Light/Dark operate 1-turn potentiometer (certain models) Red LED 3000 Lux: inc. lam 10000 Lux: sun light Infrared 880 nm (diffuse, retro, thru-beam) Visible red 660 nm (Fixed focus, fiber) -15C to +55C (+5F to +131F) -20C to +70C (-4F to +158F) IP 67 50G, 10 to 55 Hz at 1.5mm on all 3 axis 35 to 85% (non-condensing) Plastic PMMA Methacrylate 2m cable (4-wire, 22 AWG) 4-pin, M12 (micro) connector BKS S19/S20 BOS S5 DC, Selectable PNP/NPN and Light/Dark Operate Tubular Optical Sensors BOS S5 Right Angle, Cable Out 80mm to 8m BOS S5 Right Angle, Connector 80mm to 8m 16.5 BOS S5, Fiber-Optic Cable Out Depends on Fibers BOS S5, Fiber-Optic Connector Depends on Fibers 16.5 M18x1 M18x1 M18x1 3 3 13 13 M18x1 37.4 sn LED LED BOS S5-5-C8-35 BOS S5-5-C8-37 BOS S5-5-C30-35 BOS S5-5-C30-37 BOS S5-5-A2-35 BOS S5-5-A2-37 BOS S5-5-B1.5-35 BOS S5-5-B1.5-37 BLE S5-5-F8-35 BLE S5-5-F8-37 BLS S5-5-G8-05 BLS S5-5-G8-07 22 22 8 LED 70.4 37.4 sn sn 8 sn 55 55 32 32 22 70.4 22 22 22 LED BOS-S5-5-E1-30 Infrared 880 nm 10 to 30 Vdc <1.5 V 75 Vdc 150 ma 30 ma Short circuit, polarity reversal 1 ms, 2 ms for thru-beam 500 Hz, 250 for thru-beam Wire option PNP/NPN Wire option Light/Dark operate 1-turn potentiometer (certain models) Red LED 3000 Lux: inc. lam 10000 Lux: sun light Infrared 880 nm visible red 660nm 2m cable (4-wire, 22 AWG) - -15C to +55C (+5F to +131F) -20C to +70C (-4F to +158F) IP 67 50G, 10 to 55 Hz at 1.5mm on all 3 axis 35 to 85% (non-condensing) Plastic PMMA Methacrylate 4-pin, M12 (micro) connector 2m cable (4-wire, 22 AWG) BKS-S19/S20 - 2 BOS-S5-5-E1-32 visible red 660nm 4-pin, M12 (micro) connector BKS-S19/S20 2.37 Tubular Optical Sensors BOS S5 AC, 3-Wire Series Sensing Range BOS S5 Straight, Cable out 80mm to 8m BOS S5 Right Angle, Cable out 80mm to 8m BOS S5 Straight, Cable out, Fiber-optics Depends on Fiber 16.5 M18x1 M18x1 3 13 13 M18x1 22 37.4 32 55 37.4 70.4 22 70.4 22 LED 80mm (3.1 in.), Light Operate 80mm (3.1 in.), Dark Operate 300mm (11.8 in.), Light Operate Pot. 300mm (11.8 in.), Dark Operate Pot. Fixed Focus 15mm (0.6 in.), Light Operate 15mm (0.6 in.), Dark Operate Ret. Refl 0.1 to 2m (.3 to 6.6 ft), Light Operate 0.1 to 2m (.3 to 6.6 ft), Dark Operate Thru-Beam 8m (26 ft), Receiver, Light Operate Pot. 8m (26 ft), Receiver, Dark Operate Pot. 8m (26 ft), Sender Fiber-Optic AC, Light operate, Potentiometer Voltage supply Voltage drop, output Rated output current Leakage current Protections On/Off delay Switching frequency Output type Output function Sensitivity/Range adjustment Output function indication Ambient Light Protection Emitter light source: diffuse, retro, thru-beam Emitter light source, fixed focus and Fiber-optic Ambient operating temperature Storage temperature Degree of protection per IEC 529 Shock/vibration Relative Humidity Housing material Sensing face material Connection Dimension Values With potentiometer: L = 75 mm X = 52 mm Without potentiometer: L = 65 mm X = 42 mm 2.38 BOS-S5-1-C8-20-D1 BOS-S5-1-C8-10 BOS-S5-1-C30-20 BOS-S5-1-C30-10 BOS-S5-1-D15-20 BOS-S5-1-D15-10 BOS-S5-1-A2-20 BOS-S5-1-A2-10 BLE-S5-1-F8-20 BLE-S5-1-F8-10 BLS-S5-1-G8-00 8 LED LED Diffuse 8 sn sn 8 sn BOS-S5-1-C8-25 BOS-S5-1-C8-15 BOS-S5-1-A2-25 BOS-S5-1-A2-15 BLE-S5-1-F8-25 BLE-S5-1-F8-15 BLS-S5-1-G8-05 BOS-S5-1-E1-20 15 to 264 Vac, 48 to 62 Hz 10 VA max. 100 ma 1 ma max. at 264 Vac None 20 ms 25 Hz SCR + bridge rectifier Light/Dark operate models 1-turn potentiometer (certain models) Red LED 3000 Lux: inc. lam 10000 Lux: sun light Infrared 880 nm Visible red 660 n -15C to +55C (+5F to +131F) -20C to +70C (-4F to +158F) IP 67 50G, 10 to 55 Hz at 1.5mm on all 3 axis 35 to 85% (non-condensing) Plastic PMMA Methacrylate 2m cable (3-wire, 22 AWG) Tubular Optical Sensors BOS S5 Sensing Data Retroreflective BOS S5...A2... DISTANCE Excess Gain BEAM DIAMETER 1000 retroreflective 100 10 1 0.01 Thru-Beam 0.1 Distance (m) 1 10 2 BLE/BLS S5...F/G8... DISTANCE Excess Gain BEAM DIAMETER 1000 100 10 1 0.1 emitter/receiver Distance (m) 10 100 Fixed Focus BOS S5...D15... DISTANCE fixed focus diffuse scanner (red emission) BEAM DIAMETER Fixed Focus BOS S5...D14 BEAM DIAMETER 1 DISTANCE S5-X-D15 - fixed focus diffuse scanner The standard values for the operating ranges are referred to ideal conditions, i.e. clean air, clean lenses, etc. Dust, air pollution and other kinds of ambient contamination reduce the operating ranges. 2.39 Tubular Optical Sensors BOS S5 Sensing Data Diffuse (Short Range) BOS S5...C10... DISTANCE Excess Gain BEAM DIAMETER 1000 100 10 1 1 10 100 Distance (mm) 1000 Diffuse (Long Range) BOS S5...C350... Excess Gain BEAM DIAMETER 1000 S5-X-C30 - diffuse scanner (long distance) 100 10 1 1 10 100 Distance (mm) 1000 Polarized Retroreflective BOS S5...B1.5... S5-X-B1.5 - polarized retroreflective 2.40 DISTANCE Excess Gain BEAM DIAMETER 1000 100 10 1 0.01 0.1 Distance (m) 1 10 Tubular Optical Sensors BOS S5 Wiring Data Connections DC Type DC Type DC Type Light-Mode NPN (light on) Dark-Mode NPN (dark on) BROWN BROWN + BLUE BLUE WHITE WHITE BLACK = = = = BROWN + BLUE WHITE BLACK Thru Beam Diffuse Retro Thru Beam (Fiber Optic) N/C N/O N/C N/C Light-Mode PNP (light on) BROWN + BLUE BLACK = = = = N/C N/O N/C N/C Thru Beam Diffuse Retro Thru Beam (Fiber Optic) 3 + - 4 1 (3) BLACK 10 to 30 Vdc 2 TEST + TEST - S19/S20 with M12 male connector BLUE BLACK + - L1 1 15 to 264 Vac 48 to 62 Hz N 2 (1) BLUE N/O N/C N/O N/O BROWN WHITE Thru Beam Diffuse Retro Thru Beam (Fiber Optic) = = = = Light-Mode PNP (dark on) WHITE AC emitter only DC emitter only BLACK Thru Beam Diffuse Retro Thru Beam (Fiber Optic) AC Type + AC other models L1 BLACK 1 (3) N BLUE 2 (1) Q WHITE 2 1 3 4 15 to 264 Vac 48 to 62 Hz 2 3 (4) LOAD 100 mA max. = = = = N/O N/C N/O N/O 2.41