Feb.1999
MITSUBISHI DIODE MODULES
RM100DZ/CZ-M,-H
HIGH POWER GENERAL USE
INSULATED TYPE
OUTLINE DRAWING & CIRCUIT DIAGRAM Dimensions in mm
APPLICATION
AC motor controllers, DC motor controllers, Battery DC power supplies,
DC power supplies for control panels, and other general DC power equipment
RM100DZ/CZ-M,-H
IF(AV) Average forward current .......... 100A
VRRM Repetitive peak reverse voltage
................400/800V
DOUBLE ARMS
Insulated Type
UL Recognized
Yellow Card No. E80276 (N)
File No. E80271
93.5
80
17.5 20 20 3–M5
2–φ6.5
12.5
26
6.5
21
30
(DZ)
(CZ)
A
1
K
2
SR
1
SR
2
K
1
A
2
A
1
SR
1
SR
2
K
1
K
2
A
2
LABEL
Not Recommend
for New Design
Feb.1999
H
800
960
640
ABSOLUTE MAXIMUM RATINGS
Unit
V
V
V
MITSUBISHI DIODE MODULES
RM100DZ/CZ-M,-H
HIGH POWER GENERAL USE
INSULATED TYPE
M
400
480
320
Symbol
VRRM
VRSM
VR (DC)
Parameter
Repetitive peak reverse voltage
Non-repetitive peak reverse voltage
Reverse DC voltage
Voltage class
Unit
A
A
A
A2s
Hz
°C
°C
V
N·m
kg·cm
N·m
kg·cm
g
Conditions
Single-phase, half-wave 180° conduction, TC=115°C
One half chcle at 60Hz, peak value
Value for one cycle of surge current
Charged part to case
Main terminal screw M5
Mounting screw M6
Typical value
Ratings
157
100
2000
1.7 × 104
1000
–40~+150
–40~+125
2500
1.47~1.96
15~20
1.96~2.94
20~30
160
Symbol
IF (RMS)
IF (AV)
IFSM
I2t
f
Tj
Tstg
Viso
Parameter
RMS forward current
Average forward current
Surge (non-repetitive) forward current
I2t for fusing
Maximum operating frequency
Junction temperature
Storage temperature
Isolation voltage
Mounting torque
Weight
Unit
mA
V
°C/W
°C/W
M
Limits
Symbol
IRRM
VFM
Rth (j-c)
Rth (c-f)
Parameter
Repetitive reverse current
Forward voltage
Thermal resistance
Contact thermal resistance
Insulation resistance
Test conditions
Tj=150°C, VRRM applied
Tj=25°C, IFM=320A, instantaneous meas.
Junction to case (per 1/2 module)
Case to fin, conductive grease applied (per 1/2 module)
Measured with a 500V megohmmeter between main terminal
and case
Min.
10
Typ.
Max.
20
1.25
0.3
0.2
ELECTRICAL CHARACTERISTICS
Not Recommend
for New Design
Feb.1999
–3
10
–2
10
–1
10
0
10
0
10
1
10
3
10
2
10
1
10
0
10
0.4
7
5
3
2
7
5
3
2
7
5
3
2
0.8 1.2 2.0 2.4
1.6
T
j
=25°C
705030207532
0
400
2000
101 100
800
1200
1600
753275327532
0.40
0
0.05
7532
0.10
0.15
0.20
0.25
0.30
0.35
160
00 80 16040
20
6020
40
60
80
100
120
140
100 120 140
160
60 0 40 16020 60
80
100
120
140
80 100 120 140
THREE-PHASE
OPERATION
SINGLE-PHASE
OPERATION
DC
OPERATION
THREE-PHASE
OPERATION
RESISTIVE, INDUCTIVE LOAD
RESISTIVE, INDUCTIVE LOAD
SINGLE
PHASE
OPERATION
DC OPERATION
MITSUBISHI DIODE MODULES
RM100DZ/CZ-M,-H
HIGH POWER GENERAL USE
INSULATED TYPE
PERFORMANCE CURVES
MAXIMUM FORWARD CHARACTERISTIC ALLOWABLE SURGE (NON-REPETITIVE)
FORWARD CURRENT
FORWARD CURRENT (A)
CONDUCTION TIME
(CYCLES AT 60Hz)
FORWARD VOLTAGE (V)
MAXIMUM TRANSIENT THERMAL IMPEDANCE
(JUNCTION TO CASE)
MAXIMUM POWER DISSIPATION
TIME (s) AVERAGE FORWARD CURRENT (A)
ALLOWABLE CASE TEMPERATURE
VS. AVERAGE FORWARD CURRENT
CASE TEMPERATURE (°C)
AVERAGE FORWARD CURRENT (A)
TRANSIENT THERMAL IMPEDANCE
(°C/W)
SURGE (NON-REPETITIVE)
FORWARD CURRENT (A)
POWER DISSIPATION (W)
Not Recommend
for New Design