Specifications
1523 1524
Input channels 1 2
Resolution PRTs and thermistors: 0.001°
thermocouples: 0.01°
Logging 25 readings with statistics 25 readings with
statistics15,000 time
and date stamped
Sample interval (normal) 1 second 1 second
(simultaneous
measurement)
Typical sample interval (fast mode)* 0.3 seconds
Sensor types PRTs, RTDs, thermistors, and thermocouples
Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
Statistics Maximum, minimum, average, standard deviation
Trending Scale: ± 10 °C (18 °F), ± 1 °C (1.8 °F), ± 0.1°C (0.18 °F),
± 0.01°C (0.018 °F), 10 minutes of real-time data
Power requirements 3 AA alkaline batteries, 12 V dc universal power supply
Size (HxWxD) 96 mm x 200 mm x 47 mm (3.75 in x 7.9 in x 1.86 in)
Weight 0.65 kg (1.4 lb)
Computer interface RS-232, 9940 I/O ToolKit software included
Safety EN61010-1:2001, CAN/CSA C22.2 No. 61010.1-04
Environmental conditions for best accuracy: 13 °C to 33 °C (55.4 °F to 91.4 °F)
Millivolt range and accuracy –10 mV to 75 mV, ± (0.005 % + 5 µV)
Internal reference junction compensation ± 0.2 °C (± 0.36 °F)
Resistance range and accuracy 0 Ω to 400 Ω ± (0.004 % + 0.002 Ω)
200 Ω to 50 kΩ ± (0.01 % + 0.5 Ω)
50 kΩ to 500 kΩ ± (0.03 %)
Temperature coefficient, voltage:
–10 °C to 13 °C , +33 °C to 60 °C
(14 °F to 55.4 °F, 91.4 °F to 140 °F)
± (0.001 %/°C + 1 mV/°C)
Temperature coefficient, resistance:
–10 °C to 13 °C , +33 °C to 60 °C
(14 °F to 55.4 °F, 91.4 °F to 140 °F)
0.0008 %/°C + 0.0004 Ω (0 Ω to 400 Ω)
0.002 %/°C + 0.1 Ω (0 Ω to 50 kΩ)
0.06 %/°C + 0.1 Ω (50 kΩ to 500 kΩ)
Excitation current, resistance 1 mA (0 Ω to 400 Ω)
10 µA (0 Ω to 50 kΩ)
2 µA (50 kΩ to 500 kΩ)
*See technical manual for sample interval details by sensor type and number of inputs.
Equivalent temperature accuracies for
selected sensors derived from primary
specifications (Ω, mV)
Temperature, thermocouples
Type Range Measure accuracies
K–200 °C to 0 °C
(-328 °F to 32 °F) ± 0.61 °C
(± 1.10 °F)
0 °C to 1370 °C
(32 °F to 2498 °F) ± 0.24 °C
(± 0.43 °F)
R–20 °C to 0 °C
(4 °F to 32 °F) ± 1.09 °C
(± 1.96 °F)
0 °C to 500 °C
(32 °F to 932 °F) ± 0.97 °C
(± 1.71 °F)
500 °C to 1750 °C
(932 °F to 3182 °F) ± 0.49 °C
(± 0.88 °F)
S–20 °C to 0 °C
(4 °F to 32 °F) ± 1.05 °C
(± 1.89 °F)
0 °C to 500 °C
(32 °F to 932 °F) ± 0.95 °C
(± 1.71°F)
500 °C to 1750 °C
(932 °F to 3182 °F) ± 0.56 °C
(± 1.01 °F)
Accuracies are based on internal reference junction com-
pensation. Refer to technical manual for greatly improved
accuracies using external reference junctions.
Accuracies of selected readout/probe
combinations (±°C)
Temperature 5616-12 5615-6 5627A-12 5610-9
-200 °C (-328 °F) 0.014 0.025 0.027 n/a
0 °C (32 °F) 0.021 0.021 0.049 0.009
100 °C (212 °F) 0.027 0.028 0.065 0.009
300 °C (572 °F) 0.040 0.043 0.103 n/a
420 °C (788 °F) 0.050 n/a 0.130 n/a
Includes readout accuracy,
probe calibration, and probe drift
Ordering Information
1523* Reference Thermometer, Handheld, 1 Channel
1524* Reference Thermometer, Handheld, 2 Channel, Data Logger
1523-P1 1523 Bundled with 5616 PRT [–200 °C to 420 °C (-328 °F to 788 °F), NIST Traceable Calibration,
100 ohm, 6.35 mm x 305 mm (1/4 in x 12 in)], Universal TC INFO-CON Connector, TPAK, and Case
1523-P2 1523 Bundled with 5628 PRT [–200 °C to 660 °C (-328 °F to 1220 °F), Accredited Calibration, 25 ohm,
6.35 mm x 305 mm (1/4 in x 12 in)], Universal TC INFO-CON Connector, TPAK, and Case
1523-P3 1523 Bundled with 5627A PRT [–200 °C to 420 °C (-328 °F to 788 °F), Accredited Calibration, 100 ohm,
6.35 mm x 305 mm (1/4 in x 12 in)], Universal TC INFO-CON Connector, TPAK, and Case
1524-P1 1524 Bundled, with 5616 PRT, Universal TC INFO-CON Connector, TPAK, and Case
1524-P2 1524 Bundled with 5628 PRT, Universal TC INFO-CON Connector, TPAK, and Case
1524-P3 1524 Bundled with 5627A PRT, Universal TC INFO-CON Connector, TPAK, and Case
*Requires an optional probe
Calibration options
1523-CAL 1523 Accredited Calibration
1524-CAL 1524 Accredited Calibration
1929-2 System Verification, PRT with Readout, Accredited
1929-5 System Verification, Thermistor with Readout, Accredited
1930 System Calibration, PRT with Readout, Accredited
1935 System Calibration, Thermistor with Readout, Accredited
1925-A Accredited Thermistor Calibration, 0 °C to 100 °C (23 °F to 212 °F)
1523/1524 Reference Thermometers Fluke Calibration 3