54TECHNICAL 54 COOLING DATASHEET FILTER FAN PLUS FPI/FPO 018 | up to 727 m/h (291 x 291 mm) >>New air-flap outlet technology for high airflow >>Easy mounting >>Protection type test/Environmental rating by independent testing institutes (VDE and UL) >>Two systems for optimal airflow (FPI/FPO) >>Standard enclosure cut-out sizes (5 sizes) >>One filter mat Filter fans are used to provide an optimum climate in enclosures and cabinets with electrical/electronic components. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting airflow prevents formation of localised hot pockets in installations and protects electronic components from overheating. The Filter Fan Plus series uses a new air-flap outlet technology for the air outlet and thus reaches a high degree of airflow. A ratchet mechanism is used for mounting and provides high stability and tightness. Depending on the application there are two systems that are available - the FPI or FPO system. The FPI system is a standard installation with a filter fan in the lower part of the enclosure which ensures that fresh air is fed into the enclosure (airflow direction "In"). This system consists of a filter fan and exit filter. Whereas in the FPO system, the filter fan is located in the upper area of the enclosure to avoid heat buildups (airflow direction "Out"). The FPO system is composed of an intake filter and exit filter fan. The Filter Fan Plus series has been designed for indoor use. TECHNICAL DATA warm SYSTEM FPI Exit Filter FPI 118 Air-flaps Filter Fan FPI 018 cold Filter mat 1 Axial fan, ball bearing service life L10 at +40 C (+104 F): min. 76,000 h rotor metal Connection 3-pole clamp for 2.5 mm, clamping torque 0.8 Nm max. Casing, hood, flaps plastic according to UL94 V-0, light grey; UV light resistant according to UL746C (f1) Enclosure cut-out 291 x 291+1 mm Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness 1 -- 4 mm). Additional use of screws possible if needed1. Filter mat G3 acc. to DIN EN 779, average arrestance Aa 84 % Filter material synthetic fibre with progressive construction, temperature resistant to +100 C, self-extinguishing class F1, moisture resistant to 100 % RH, reusable Operating temperature 50 Hz: -25 to +55 C (-13 to +131 F) 60 Hz: -25 to +35 C (-13 to +95 F) Storage temperature -40 to +70 C (-40 to +158 F) Operating/Storage humidity max. 75 % RH (non-condensing) Protection type/Protection class IP54 / I (earthed) Environmental rating UL/NEMA UL TYPE 12 / NEMA 12 Approvals VDE, UL File No. E234324, EAC Note other voltages on request Drilling marks for screw mounting are indicated on mounting frame. AIRFLOW DIRECTION "IN": FILTER FAN FPI 018 Art. No. Operating voltage Air volume, free flow Air volume with exit filter 01874.0-30 AC 230 V, 50/60 Hz 433 m/h 373 m/h 01874.9-30 AC 115 V, 50/60 Hz 394 m/h 339 m/h Current consumption (50/60 Hz) Power consumption Average noise level (DIN EN ISO 4871) Depth in enclosure Weight (approx.) Filter mat 400/480 mA 95 W 62 db (A) 160 mm 3.1 kg G3 660/800 mA 90 W 61 db (A) 160 mm 3.1 kg G3 AIRFLOW DIRECTION "IN": EXIT FILTER FPI 118 Art. No. Depth in enclosure Weight (approx.) Air outlet 11874.0-00 50 mm 1.0 kg air-flap outlet technology 19.03.2019 | Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. www.stego.de | www.stego.co.uk | www.stegonorden.se PRODUCT CATALOGUE - STEGO 55 55 COOLING www.stego.de | www.stego.co.uk | www.stegonorden.se STEGO - PRODUCT CATALOGUE TECHNICAL DATASHEET warm SYSTEM FPO Filter Fan FPO 018 Air-flaps Intake Filter FPO 118 AIRFLOW DIRECTION "OUT": FILTER FAN FPO 018 Art. No. Operating voltage Air volume, free flow Air volume with intake filter 01884.0-00 AC 230 V, 50/60 Hz 727 m/h 413 m/h 01884.9-00 AC 115 V, 50/60 Hz 703 m/h 391 m/h Current consumption (50/60 Hz) Power consumption Average noise level (DIN EN ISO 4871) Depth in enclosure Weight (approx.) Air outlet 400/480 mA 95 W 63 db (A) 160 mm 3.2 kg air-flaps 660/800 mA 90 W 62 db (A) 160 mm 3.2 kg air-flaps AIRFLOW DIRECTION "OUT": INTAKE FILTER FPO 118 Art. No. Depth in enclosure Weight (approx.) Filter mat 11884.0-30 25 mm 0.8 kg G3 acc. to DIN EN 779, average arrestance Aa 84 % FILTER MAT FM 086 Filter class 283 x 283 mm Average arrestance Aa 1 packing unit G3 acc. to DIN EN 779 Art. No. 08637.0-00 84 % 5 pieces TECHNICAL DRAWINGS 29 50 29 322 160 29 50 29 FPI 118 291 160 29 322 160 29 +1 0 ENCLOSURE CUT-OUT 25 29 25 291 29 291 291 291 291 291 FPI 018 322 291 160 291 322 FPO 018 291 FPO 118 +1 0 ENCLOSURE CUT-OUT 19.03.2019 | Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. cold Filter mat