AC/DC Enclosed Power Supply * TXL 060/070 Series, 50-70 Watt Compact metal case with screw terminal block * Multiple output models with isolated outputs * * Universal input 85 - 264 Vac * * * * Compliance to EN 61000-3-2 EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1 Short circuit and overvoltage protection International safety approvals CB 3 year product warranty Scheme UL 60950-1 The TRACO POWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). Models Order Code Power Output voltage Vout 3 Vout 1 Vout 2 Efficiency Models TXL 060-3.3S Vout 1 50 W 3.3 VDC 15.0 A 74 % TXL 060-05S 60 W 5 VDC 12.0 A 77 % TXL 070-12S 72 W 12 VDC 6.0 A 83 % TXL 070-15S 72 W 15 VDC 4.8 A 84 % TXL 070-24S 72 W 24 VDC 3.0 A 85 % TXL 070-48S 72 W 48 VDC TXL 060-0512DI 1) 60 W +5 VDC +12 VDC 8.0 A 4.0 A 78 % TXL 060-0524DI 1) 60 W +5 VDC +24 VDC 6.0 A 2.2 A 79 % TXL 060-0521TI 1) 60 W +5 VDC +12 VDC -5 VDC 8.0 A 3.5 A 1.0 A 77 % TXL 060-0522TI 1) 60 W +5 VDC +12 VDC -12 VDC 7.0 A 3.5 A 1.0 A 78 % TXL 060-0533TI 1) 60 W +5 VDC +15 VDC -15 VDC 7.0 A 3.0 A 1.0 A 79 % TXL 060-0534TI 1) 60 W +5 VDC +12 VDC +24 VDC 6.0 A 1.5 A 1.2 A 80 % 1) Vout 2 Output current max. max. Vout 3 1.5 A typ. 87 % Total power should not exceed max. output power www.tracopower.com Page 1 of 4 TXL 060/070 Series, 50-70 Watt Input Specifications Input voltage range - nominal 100 - 240 VAC - AC range (universal input) 85 - 264 VAC - DC range 120 - 375 VDC Input frequency 47 - 63 Hz Input current at full load - at 100 VAC 1.8 A max. Input inrush current - at 115 VAC / 230 VAC 30 A max. / 60 A max. Zero load power consumption only single output models: 0.75 W max. (green mode design) Recommended circuit breaker (characteristic C or slow bow fuse) 5 A Output Specifications Output voltage adjustment range 10 % (only Vout 1) Regulation - Input variation - Load variation (20 - 100%) Minimum load 1.0 % max. main output: 2.0 % max. Vout 2, Vout 3: 5.0 % max. single output models: not required dual output models: Vout 1 requires 1.0 A triple output models: Vout 1 requires 0.5 A Temperature coefficient 0.02 %/K Start-up time 1 s max. Rise time 20 ms max. Hold-up time - at 230 VAC 60 ms min. Ripple and noise - measured with external capacitors: (20Mhz Bandwidth) - Vout 1, Vout 2, Vout 3: 3.3 & 5 Vout: 12 Vout: 15 Vout: 24 Vout: 48 Vout: Overload protection by current limitation 0.1 F and 47 F parallel capacitor 70 mVp-p typ. 120 mVp-p typ. 150 mVp-p typ. 200 mVp-p typ. 250 mVp-p typ. 105 - 150 % of Iout max. Short circuit protection hiccup mode (automatic recovery) Overvoltage protection (Latch off, recovery after restart) 115 - 140 % of nominal Vout (only Vout 1) Capacitive load www.tracopower.com/products/txl-capload.pdf General Specifications Temperature ranges - Operating -20C to +70C (with derating) - Storage -40C to +85C Output power derating - Temperature 2.5 %/K above +45C - Low input voltage 0.7 %/V below 100 VAC Cooling natural convection (20 lfm), no internal fan Humidity (non condensing) 20 - 90 % rel. H max. Altitude during operation 2000 m Isolation voltage (60 sec.) - Input / Output 3000 VAC - Input / PE 1500 VAC - Output / PE 500 VAC Isolation resistance (at 500 VDC) 100 MOhm min. Leakage current (at 264 VAC/60Hz) 1 mA max. All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 2 of 4 TXL 060/070 Series, 50-70 Watt General Specifications (continued) Switching frequency 65 kHz typ. (pulse width modulation) Reliability (calculated MTBF) single output models:> 300`000 h dual output models: > 260`000 h dual output models: > 258`000 h Electromagnetic compatibility(EMC), emissions - Conducted input RI suppression EN 55022 class B, FCC Part 15 level B - Harmonic current emissions IEC/EN 61000-3-2, class A - Voltage flicker IEC/EN 61000-3-3 (built-in PFC choke) Electromagnets compatibility (EMC), immunity - Electrostatic discharge ESD - RF field immunity - Electrical fast transients/burst immunity - Surge - Conducted RF - Magnetic field - Voltage dip according EN 55024 IEC/EN 61000-4-2, 4 kV / 8 kV, perf. criteria A IEC/EN 61000-4-3, 3 V/m, perf. criteria A IEC/EN 61000-4-4, 2 kV, perf. criteria A IEC/EN 61000-4-5, 1 kV / 2 kV, perf. criteria A IEC/EN 61000-4-6, 3 Vrms perf. criteria A IEC/EN 61000-4-8, 3 A/m perf. criteria A IEC/EN 61000-4-11 >95 %, perf. criteria A, 0.5 periods 30 %, perf. criteria A, 25 periods >95 % perf. criteria B, 250 periods Safety standards UL 60950-1, IEC/EN 60950-1 Safety approvals - UL/cUL www.ul.com -> certifications -> File: e188913 - CB report www.tracopower.com/overview/txl Environmental compliance - Reach www.tracopower.com/products/reach-declaration.pdf - RoHS RoHS directive 2011/65/EU Connection single output models: 7 pole terminal pitch (9.5mm with plastic cover) dual / triple output models: 9 pole terminal pitch (7.62mm with plastic cover) Casing material nickel plated steel (cover), aluminium (chassis) Weight single output models: 0.60 kg dual output models: 0.58 kg triple output models: 0.60 kg All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 3 of 4 TXL 060/070 Series, 50-70 Watt 10 max. 19 (0.75) 159 10 118 (4.65) 19 (0.75) (0.39) 18 3 x M3 THD (0.71) Outline Dimensions Dimensions in [mm], () = Inch Tolerances 0.5 (0.02) (6.26) (0.39 max.) Dual & Triple output models Single output 95 2 x M3 THD (bottom) (3.74) Top view (1.26) 1 2 3 4 5 6 7 32 1 2 3 4 5 6 7 8 9 78 57 38 (3.07) (2.24) (1.50) Screw Terminal Pin Single Dual Triple 1 AC L AC L AC L 2 AC N AC N AC N 3 PE PE PE 4 - Vout No con. + Vout 3 * 5 - Vout No con. - Vout 3 * 6 + Vout - Vout 1 - Vout 1 7 + Vout + Vout 1 + Vout 1 8 - - Vout 2 - Vout 2 9 - + Vout 2 + Vout 2 * Opposite polarity for TXL 060-0534TI (c) Copyright 2018 Traco Electronic AG Specifications can be changed without notice! Rev. November 15, 2018 www.tracopower.com Page 4 of 4