ENVIRONMENT
PROTECTION
SPECIFICATION
MODEL RS-150-3.3 RS-150-5 RS-150-12 RS-150-15 RS-150-24 RS-150-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
SETUP,RISE,HOLDTIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 5V 12V 15V 24V 48V
30A 26A 12.5A 10A 6.5A 3.3A
0~30A 0~26A 0~12.5A 0~10A 0~6.5A 0~3.3A
99W 130W 150W 150W 156W 158.4W
80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
3.2V~3.5V 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V
3.0% 2.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 1.0% 0.5% 0.5% 0.5% 0.5%
800ms,20ms,20ms/230VAC1200ms,30ms,10ms/115VAC atfullload
88~132VAC/176~264VACselectedbyswitch248~373VDC(300VACpeak5sec.Nodamage)
47~63Hz
75%
3.8~4.45V 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 55.2~64.8V
78% 83% 84% 86% 87%
3A/115VAC2A/230VAC
COLDSTART 50A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
-20~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
244KHrsmin.MIL-HDBK-217F(25 )
199*98*38mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
FileName:RS-150-SPEC2004-03-25
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
0.7Kg;20pcs/14Kg/0.72CUFT
150WSingleOutputSwitchingPowerSupply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High realibility
Features :
RS-150 seri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note6)