Inductive slot sensor SJ3,5-N Technical Data 0 10 2 Model Number SJ3,5-N Features * * 3.5 mm slot width Usable up to SIL2 acc. to IEC 61508 General specifications Switching element function NAMUR, NC Slot width 3.5 mm Depth of immersion (lateral) 5 ... 7 mm , typ. 6 mm Installation Output polarity NAMUR Nominal ratings Nominal voltage Uo 8.2 V (Ri approx. 1 k) 5 ... 25 V Operating voltage UB Switching frequency f 0 ... 3000 Hz Hysteresis H 0.41 ... 0.6 mm Suitable for 2:1 technology yes , Reverse polarity protection diode not required Current consumption 3 mA Measuring plate not detected 1 mA Measuring plate detected Functional safety related parameters MTTFd 8415 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0% Ambient conditions Ambient temperature -25 ... 100 C (-13 ... 212 F) Mechanical specifications Connection type flexible leads LiY , 500 mm Core cross-section 0.14 mm2 Housing material PBT/PPS Degree of protection IP67 General information Use in the hazardous area see instruction manuals 1G; 2G; 1D Category Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 EN 60947-5-2:2007 IEC 60947-5-2:2007 Standards Approvals and certificates FM approval Control drawing UL approval CSA approval CCC approval 116-0165F cULus Listed, General Purpose cCSAus Listed, General Purpose CCC approval / marking not required for products rated 36 V Dimensions 3.5 0.9 2 15 10 5 6.95 Release date: 2015-04-25 23:16 Date of issue: 2015-04-26 105910_eng.xml 3 10 19 o 1.2 Electrical Connection Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com BN BU L+ L- Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 1 Inductive slot sensor SJ3,5-N ATEX 1G Instruction Device category 1G EC-Type Examination Certificate CE marking ATEX marking Manual electrical apparatus for hazardous areas for use in hazardous areas with gas, vapour and mist PTB 99 ATEX 2219 X 0102 II 1G Ex ia IIC T6...T1 Ga Directive conformity 94/9/EG Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions Appropriate type SJ3,5-...-N... Effective internal capacitance Ci 50 nF ; a cable length of 10 m is considered. Effective internal inductance Li 250 H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. Install the device in such a way that the resin surface is not exposed to mechanical hazards. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Release date: 2015-04-25 23:16 Date of issue: 2015-04-26 105910_eng.xml Protection from mechanical danger 2 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com Inductive slot sensor SJ3,5-N ATEX 2G Instruction Manual electrical apparatus for hazardous areas Device category 2G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 99 ATEX 2219 X CE marking 0102 ATEX marking II 1G Ex ia IIC T6...T1 Ga Directive conformity 94/9/EG Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions Appropriate type SJ3,5-...-N... Effective internal capacitance Ci 50 nF ; a cable length of 10 m is considered. Effective internal inductance Li 250 H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Install the device in such a way that the resin surface is not exposed to mechanical hazards. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Release date: 2015-04-25 23:16 Date of issue: 2015-04-26 105910_eng.xml Protection from mechanical danger Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 3 Inductive slot sensor SJ3,5-N ATEX 1D Instruction Manual electrical apparatus for hazardous areas Device category 1D for use in hazardous areas with combustible dust EC-Type Examination Certificate ZELM 03 ATEX 0128 X CE marking 0102 ATEX marking II 1D Ex iaD 20 T 108 C (226.4 F) Directive conformity 94/9/EG Standards IEC 61241-11:2002: draft; prEN61241-0:2002 type of protection intrinsic safety "iD" Use is restricted to the following stated conditions Appropriate type SJ3,5-...-N... Effective internal capacitance Ci 50 nF ; a cable length of 10 m is considered. Effective internal inductance Li 250 H ; a cable length of 10 m is considered. General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Maximum housing surface temperature The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iaD. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 6007914 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. Release date: 2015-04-25 23:16 Date of issue: 2015-04-26 105910_eng.xml Electrostatic charge 4 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com