ADP Series Power Adapters
12V 25W/36W/66W
TECHNICAL DATASHEET
!
ADP 12V
Highlights & Features
Energy Star Compliance (Level VI)
IT safety approvals
100k Hours MTBF
Over-Voltage/Load/Temperature & Short Circuit protections
Model Information
ADP Series Power Adapters
Model
Number
Input Voltage
Range
Output
V
oltage
Output
Curr
ent
ADP-25FW BB
90-264Vac
12Vdc
2.1A
ADP-36PH BH
90-264Vac
12Vdc
3A
ADP-66CR BE
90-264Vac
12Vdc
5.5A
!
Specifications
Input Ratings / Characteristics
25W$
66W$
Nominal Input Voltage
115/230Vac
100-240Vac
115/230Vac
Input Voltage Range
90-264 Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
1A Max @ 100Vac
600mA @ 240Vac
1A Max at 100Vac input
voltage
2A Max at 100Vac input
voltage
Inrush Current(Cold Start)
<50A at 120VAC
No Damage at 240Vac
<90A at 230Vac
Efficiency at nominal input voltage
86% @ 115Vac
84% min, max load and
measured at the end of DC
cable.
83%
Active Mode Efficiency @ 115Vac
86.38%
>87.4%
88%
Active Mode Efficiency @ 230Vac
N/A
>84.78
88%
No Load Power Consumption
<0.1W @115Vac
<0.1W @ 115Vac/60Hz and
230Vac/50Hz
0.21w
Hold Up Time at maximum load
>16.7milliseconds@115Vac
>20 milliseconds@230Vac
5milliseconds@100Vac
10milliseconds minimum at
100Vac/50Hz.
ADP Series Power Adapters
12V 25W/36W/66W
TECHNICAL DATASHEET
!
Output Ratings / Characteristics
25W$
36W$
66W$
Rated Voltage
12V
Voltage Range(All Models)
11.4 ~ 12.6V
Current
0-2.1A
0-3A
0-5.5A
Output Ripple and Noise @20MHz.
BW, with 0.1uF ceramic and 47uF
Electrolytic Caps connected parallel
to load.
<120mVp-p
450mV pk-pk
120mV pk-pk
Turn On delay time
2 seconds @ 120Vac
5 seconds @ 100-240Vac
3 seconds @ 90Vac/60Hz
and -0°C to +45°C; OR
10 seconds at -20°C to 0°C.
Rise Time
<20ms
30mS
30ms
Max Load Capacitance (microfarads)
1000
470
1000
Load Transient Response
0%-50%-0% and 50%-100%-
50% of full nominal load.
frequency is 60Hz, 50% duty
cycle and the slew rate shall
be at 0.02A/us.
0.1~1.5A & 1.5A~3A load at
2.5A/us slew rate , 50% Duty
cycle , Frequency be
operated 100Hz ~ 10KHz
25 % step load change at 1
A/s.at frequency 500Hz with
50% duty.
Environment, EMI and Immunity
!!
25W$
36W$
66W$
Operating Temperature
0 °C to +40 °C
-20 °C to +45 °C
Shipping/Storage Temperature
-20 °C to +75 °C
-30 °C to +80 °C
-40 °C to +85 °C
Operating Humidity
Up to 95%
8% to 90% RH (Non-
Condensing)
10% to 95% RH (Non-
Condensing)
Shipping/Storage Humidity
5% to 95% RH (Non-Condensing)
10-95% RH (Non-Condensing)
Operating Altitude
Maximum of 3700 meters
(12000 feet)
Maximum of 5000 meters
-150 to 3000 meters
(-500 to 10000 feet)
Lightning Surge Immunity
Per IEC-1000-4-5
L-N, L-G, N-G, IEEE
C62.41.2, 0.5 µs 100 kHz
Ring Wave, 1.2/50 µs - 8/20
µs Combination Wave
6KV, Criterion B
Line Neutral 1KV/1.2 *
50us Level 3 Criteria A
L-N, L-G, N-G
Combination Wave
6KV, Criterion B
Electric Fast Transients (EFT)
EN61000-4-4 +/-1kV on
input power lines; Criterion B
I EC-1000-4-4/1995 (EN
61000-4-4) Level 3
requirements
EN61000-4-4 +/-1kV on
input power lines; Criterion B
Electrostatic Discharge (ESD)
Per IEC-61000-4-2
Contact discharge±8KV
Air discharge±15KV
+/-8kV air discharge; +/-6kV contact
discharge;
Dielectric Withstand Voltage (HI-
POT)
3KV AC RMS from AC Input to Output
Leakage Current
<250uA at 264 Vac
<100uA at 240Vac/50Hz
<250uA at 264 Vac
Insulation Resistance
The insulation resistance
shall be not less than 4M
ohms after application of
500Vdc/10mA for 1 minute.
The insulation resistance
shall be not less than 30M
ohms after application of
500Vdc/10mA for 1 minute.
The insulation resistance
shall be not less than 10M
ohms after application of
500Vdc/10mA for 1 minute.
Electromagnetic Interference (EMI)
CISPR 22/EN55022 Class
B.
(a) FCC Class B
(b) CISPR 22 Class B
(c) VCCI Class B
CISPR 22 :
1997/EN55022(1998) Class
B.
MTBF
200,000 hours of continuous
operation at 25
80,000 hours of continuous
operation at 25
150,000 hours of operation at
90% confidence level at
25degC
Electrolytic Capacitor Operating Life
7 years at 115VAC, 40C and
100% rated load
3 years at 115 Vac and 230
Vac, and 25degC 100%
rated load
5 years at 115 Vac and 230
Vac, and 25degC 100%
rated load
ADP Series Power Adapters
12V 25W/36W/66W
TECHNICAL DATASHEET
!
Protections
25W$
36W$
66W$
Overvoltage
<150% of nominal output
voltage (Recovery mode)
Latch Mode
Latch Mode
Overload / Overcurrent
<150% maximum load
current (Recovery mode)
Auto-Recovery
Auto-Recovery
Over Temperature
Recovery mode
Latch Mode
Auto-Recovery
Short Circuit
Recovery mode
Auto-Recovery
Auto-Recovery
!
Mechanical
25W$
36W$
66W$
Color
Black
Outline Dimensions (L x W x D)
102 * 36.8 * 49 mm
89.5.0 * 37.0 * 26.5 mm
132 * 62 * 34.1 mm
AC Inlet Type
Fixed 2 pin AC Blades Socket C6 type Socket C14 Type
DC Cable Type
UL2468 #AWG20
UL1571 #AWG17
UL1571 #AWG14
DC Cable Length
1500 mm
1800 mm
1500 mm
DC Connector - OD
2.1 mm
4.75 mm
2.5 mm
DC Connector - ID
5.5 mm
1.7 mm
5.5 mm
DC Connector - Length
10.5 mm
12.5 mm
9.5 mm
Mechanical
ADP-25FW BB
TECHNICAL DATASHEET
ADP Series Power Adapters
12V 25W/36W/66W
!
!
$www.DeltaPSU.com (January 2016, Rev. 1.0)$$
!
4!
ADP-36PH BH
ADP-66CR BE