14
Pressure
High Accuracy Heavy-Duty Pressure Transducers
APPLICATIONS
Hydraulic and pneumatic
systems
Industrial machinery
and machine tools
Injection molding machines
Stamping and forming presses
Pumps and compressors
Laboratory and test equipment
Railroad equipment
HVAC systems
Medical
Refrigeration equipment
Marine
Power generation
Construction
Petrochemical
Water management
FEATURES
Advanced diffused semi-
conductor and sputtered thin
film sensor for maximum
stability
High accuracy and long term
stability
Ranges from vacuum to
145,000 psi
Corrosion resistant
stainless steel construction
Span and zero adjustments
Compatible with NOSHOK
1800, 1900 and 2000 Series
Smart System Indicators
Designed for heavy-duty applications
requiring high accuracy and durability
Extreme high pressure ranges from
vacuum to 145,000 psi; Absolute ranges
from 15 psia to 300 psia
Span and zero adjustments
Advanced diffused semi-conductor and
sputtered thin lm sensor for maximum
stability
Excellent accuracy, shock resistance, and
long term reliability
Rugged corrosion-resistant stainless steel
construction
Available in a wide variety of electrical and
process con gurations
Compatible with NOSHOK 1900C and 2000
Series Smart System Indicators
Also available with our 1800 Series
Attachable Loop Indicator
CE compliant to suppress RFI, EMI and ESD
Final calibration tests prior to shipment
ensures 100% “out of the box” reliability
615/616
615/616 SERIES
SPECIFICATIONS
Output signals 4 mA to 20 mA, 2-wire; 1 Vdc to 5 Vdc, 1 Vdc to 6 Vdc, 1 Vdc to 11 Vdc,
3-wire; 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 3-wire; 0 Vdc to 5 Vdc and
0 Vdc to 10 Vdc, 4-wire
Pressure ranges Standard gauge ranges from vacuum to 145,000 psig;
Standard absolute ranges from 15 psia to 300 psia
Proof pressure 3 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
1.75 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
1.5 times full scale for 0 psi to 15,000 psi range
1.2 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Burst pressure 3.8 times full scale for ranges 0 psi to 2 psi through 0 psi to 200 psi
4 times full scale for ranges 0 psi to 300 psi through 0 psi to 10,000 psi
3 times full scale for 0 psi to 15,000 psi range
1.5 times full scale for ranges 0 psi to 20,000 psi through 0 psi to 145,000 psi
Accuracy ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL); (includes the effects
of non-linearity, hysteresis, non-repeatability, zero point and full scale errors)
Repeatability ±0.05% full scale
Hysteresis ±0.1% full scale
Stability ±0.2% full scale for 1 year, non-accumulating
Power supply* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
10 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire)
10 Vdc to 30 Vdc (1 Vdc to 6 Vdc, 3-wire)
10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
14 Vdc to 30 Vdc (1 Vdc to 11 Vdc, 3-wire)
Load limitations (VPower-10)/0.020 Amp for 4 mA to 20 mA
10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
5,000 Ω for 0 Vdc to 5 Vdc, 3-wire
Wetted materials 316 stainless steel for vacuum through 300 psi; 17-4PH stainless steel sensing
diaphragm and 316 stainless steel process connection for higher ranges
Housing materials 316 stainless steel
Temperature ranges Compensated 32 °F to 175 °F (0 °C to 80 °C)
Effect ± 0.01%/ °F for zero and span
Storage - 40 °F to 212 °F (-40 °C to 100 °C)
Medium - 20 °F to 212 °F (-30 °C to 100 °C)
Ambient - 15 °F to 175 °F (-10 °C to 80 °C)
Response time Less than 1 ms (between 10% and 90% full scale)
Durability >100,000,000 full scale cycles
Adjustment ± 10% full scale for zero and span
Environmental protection NEMA 4X, IP65 (IEC 529)
Electromagnetic rating 2004/108/EEC, EN 61326 Emission (Group 1, Class B) and Immunity
(industrial locations)
Electrical protection Reverse polarity, overvoltage and short circuit protection
Shock Less than ± 0.05% full scale effect or 1,000 g’s @ 20 ms on any axis
Vibration Less than ± 0.01% full scale effect for 15 g’s @ 0 Hz to 2,000 Hz on any axis
Weight Approximately 7.2 oz.
High temperature
version available upon
request
Also available with our 1800 Series Attachable
Loop Indicator. See page 44 for more information.
* Unregulated power supplies
15
3-WIRE WIRING
Hirschmann Cable M12 Bendix
+ Supply 1 Red 1 A
Common 2 Black 3 B
+ Output 3 White 4 C
ORDERING INFORMATION
DIMENSIONS
WIRING DIAGRAMS
ELECTRICAL CONNECTIONS
61 5/616
SERIES
2-WIRE WIRING
Hirschmann Cable M12 Bendix
+ Supply 1 Red 1 A
+ Output 2 Black 3 B
Hirschmann
1.06"
(27 mm)
1.89"
(48 mm) 1.06" sq.
(27 mm)
1.10"
(28 mm)
2.16"
(55 mm)
0.75"
(19 mm)
1/2" NPT
1.06" HEX
(27 mm)
NOTE
See 621/622 Series
for G1/2B and G1B
Front Flush Process
Connection Dimensions
pg. 29
1.36
(34.5 mm)
1/2 NPT Conduit with
36 jacketed cable
1.48"
(37.5 mm)
Integral 36 cable
0.68"
(17.3 mm)
*6 pin Bendix
0.51"
(13 mm)
*M12 x 1 (4-pin)
0.54"
(13.8 mm)
Hirschmann with
1/2 NPT Female
ISO 4400 conduit
1.65"
(42 mm)
1.06" sq.
(27 mm)
*Note: mate supplied
separately or customer
supplied
615 500 – 1 – 1 8 – 1 – ORF
EXAMPLE
Series ........................................................ 615
Pressure range .................. 0 psig to 500 psig
Accuracy ............................................ ±0.25%
Output signal .............. 4 mA to 20 mA, 2-wire
Process connection ...............1/2 NPT Male
Electrical connection ..................... 3 6 cable
Option ................................... Threa ded orifi ce
Outline Dimensions
ORDERING INFORMATION
SERIES 615 (Internal diaphragm) 616 (Front flush diaphragm)
PRESSURE
RANGES
30vac -30 inHg to 0 psig 2 0 psig to 2 psig 150 0 psig to 150 psig 2000 0 psig to 2,000 psig 20000 0 psig to 20,000 psig 145000 0 psig to 145,000 psig
30/15 -30 inHg to 15 psig 3 0 psig to 3 psig 200 0 psig to 200 psig 3000 0 psig to 3,000 psig 30000 0 psig to 30,000 psig 15A 0 psia to 15 psia
30/30 -30 inHg to 30 psig 5 0 psig to 5 psig 300 0 psig to 300 psig 4000 0 psig to 4,000 psig 36000 0 psig to 36,000 psig 30A 0 psia to 30 psia
30/60 -30 inHg to 60 psig 10 0 psig to 10 psig 500 0 psig to 500 psig 5000 0 psig to 5,000 psig 58000 0 psig to 58,000 psig 60A 0 psia to 60 psia
30/100 -30 inHg to 100 psig 15 0 psig to 15 psig 600 0 psig to 600 psig 6000 0 psig to 6,000 psig 72000 0 psig to 72,000 psig 100A 0 psia to 100 psia
30/150 -30 inHg to 150 psig 30 0 psig to 30 psig 750 0 psig to 750 psig 7500 0 psig to 7,500 psig 87000 0 psig to 87,000 psig 150A 0 psia to 150 psia
30/200 -30 inHg to 200 psig 60 0 psig to 60 psig 1000 0 psig to 1,000 psig 10000 0 psig to 10,000 psig 100000 0 psig to 100,000 psig 200A 0 psia to 200 psia
30/300 -30 inHg to 300 psig 100 0 psig to 100 psig 1500 0 psig to 1,500 psig 15000 0 psig to 15,000 psig 115000 0 psig to 115,000 psig 300A 0 psia to 300 psia
psig = gauge pressure psia = absolute pressure Other ranges available on special request Note: Series 616 is not available in pressure ranges 10,000 psig and above
ACCURACIES 1 ±0.25% full scale (BFSL) 2 ±0.125% full scale (BFSL)
OUTPUT SIGNALS
*Ranges up to 0 psig
to 60,000 psig
1 4 mA to 20 mA, 2-wire 4 1 Vdc to 6 Vdc, 3-wire*
2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire NOTE: 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc outputs are also available in 4-wire
configurations for use with other electrical systems.
3 1 Vdc to 5 Vdc, 3-wire 6 1 Vdc to 11 Vdc, 3-wire*
PROCESS
CONNECTIONS
615: 2 1/4 NPT Male 6 9/16 -18 UNF 2B high pressure cone*
(Standard on 30,000 to 120,000 psig) 8 1/2 NPT Male
616: 11 G 1/2 B (Pressure ranges 0 psig to 30 psig) 13 G 1 B (Pressure ranges 0 psig to 30 psig) Other connections available upon request
ELECTRICAL
CONNECTIONS
1 36 cable (connected to option 8) 8 Hirschmann (DIN EN 175301-803 Form A) 25 M12 x 1 (4-pin)
36-pin Bendix 14 Hirschmann type with 1/2 NPT Female conduit 36 Integral 36 cable
6 1/2 NPT conduit w/ 36 cable
OPTIONS ORF SS Threaded orifice G1 G 1 Weld-on adapter (616 only) G 1/2 Weld-on adapter (616 only)
* Equivalent to F250C Parker Autoclave
Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.