TOTAL POWER INT'L SE-600 600W Single Output Power Supply Features : High power density 4.9w/in series 3 AC input active surge current limiting AC input range selected by switch Protections:Short circuit/Over load/Over voltage/Over temperature Forced air cooling by built-in DC fan Built-in remote sense function UL approved Low cost 2 years warranty SPECIFICATION MODEL OUTPUT SE-600-5 SE-600-12 SE-600-15 SE-600-24 SE-600-27 SE-600-48 DC VOLTAGE 5V 12V 15V 24V 27V 48V RATED CURRENT 100A 50A 40A 25A 22.2A 12.5A CURRENT RANGE 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 25A 0 ~ 22.2A 0 ~ 12.5A RATED POWER 500W 600W 600W 600W 599.4W 600W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 13.5 ~ 16.5V 22 ~ 26.4V 24 ~ 30V 43 ~ 56V 1.0% 0.5% 0.5% 1.0% 0.5% 0.5% RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% SETUP, RISE, HOLD TIME 10 ~ 13.5V 1.0% 0.5% 0.5% 2.0% 0.5% 1000ms, 50ms, 16ms/230VAC VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch FREQUENCY RANGE 47~63Hz LINE REGULATION LOAD REGULATION INPUT EFFICIENCY (Typ.) AC CURRENT 84% INRUSH CURRENT (max.) LEAKAGE CURRENT <2.0mA / 240VAC OVER LOAD 105 ~ 125% rated output power Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 87% 87% 88% 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V 7.5A/230VAC 50A/230VAC 5.75 ~ 6.3V 13.8 ~ 16.2V 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recover 85 5 (TSW1) Detect on heatsink of power transistor WORKING TEMP. Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +60 (Refer to output load derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE MTBF DIMENSION PACKING NOTE 83% 254 ~ 370VDC 12A/115VAC 30A/115VAC PROTECTION OVER VOLTAGE OTHERS 78% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 1000ms, 50ms, 14ms/115VAC at full load -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 197K hrs min. MIL-HDBK-217F (25 247*127*63.5mm (L*W*H) 2Kg; 6pcs/12Kg/0.76CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. SE-600 600W Single Output Power Supply Mechanical Specification 11.5 Case No. 926 Unit:mm 20 63.5 18 series 30 4-M3 11 220 247 O/P 2 Air flow direction 8.2 4 5 I/P 1 2 3 10 10 127 3 Top view 230/115VAC 13 1 6 CN4 RS 220 + +Adj. RS +- 16 8.5 20 30 4-M3 7.5 137 76 110 5-M3 L=6 Bottom view 32 AC input terminal : Pin No. 1 2 3 207.5 DC Output terminal : Pin No. 1~3 4~6 Assignment AC/L AC/N FG RS Connector (CN4) : JST B-XH or equivalent Assignment +V -V Derating Curve Pin No. 1 2 Assignment +S -S Mating Housing JST XHP or equivalent Terminal JST SXH-001T or equivalent Static Characteristics 100 100 Other 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 5V 60 50 40 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 ) 60 70 90 180 95 190 100 200 115 230 INPUT VOLTAGE (VAC) 60Hz 130 260