3
SPECIFICATION
SE-600-5
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISE,HOLDTIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT
5V
100A
0~100A
500W
150mVp-p
4.75~5.5V
2.0%
0.5%
2.0%
1000ms,50ms,16ms/230VAC1000ms,50ms,14ms/115VACatfullload
90~132VAC/180~264VACselectedbyswitch254~370VDC
47~63Hz
78%
12A/115VAC7.5A/230VAC
30A/115VAC50A/230VAC
<2.0mA /240VAC
105~125% ratedoutputpower
5.75~6.3V 13.8~16.2V 18~21V 27.6~32.4V 31~36.5V 57.6~67.2V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
85 5 (TSW1)Detectonheatsinkofpowertransistor
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL60950 Approved
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
-20~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.05%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
197Khrsmin.MIL-HDBK-217F(25 )
247*127*63.5mm(L*W*H)
2Kg;6pcs/12Kg/0.76CUFT
83% 84% 87% 87% 88%
0.5% 0.5% 0.5% 0.5% 0.5%
0.5% 0.5% 0.5% 0.5% 0.5%
1.0% 1.0% 1.0% 1.0% 1.0%
150mVp-p
10~13.5V
150mVp-p
13.5~16.5V
150mVp-p
22~26.4V
150mVp-p
24~30V
200mVp-p
43~56V
12V
50A
0~50A
600W
15V
40A
0~40A
600W
24V
25A
0~25A
600W
27V
22.2A
0~22.2A
599.4W
48V
12.5A
0~12.5A
600W
SE-600-12 SE-600-15 SE-600-24 SE-600-27 SE-600-48
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
High power density 4.9w/in
AC input active surge current limiting
AC input range selected by switch
Protections:Short circuit/Over load/Over voltage/Over temperature
Forced air cooling by built-in DC fan
Built-in remote sense function
UL approved
Low cost
2 years warranty
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
PROTECTION
600WSingleOutputPowerSupply SE-600 series
TOTAL POWER INT'L
MechanicalSpecification
DeratingCurve StaticCharacteristics
ACinputterminal: DCOutput terminal:
PinNo. PinNo.
1 1~3
3
4~62
Assignment Assignment
AC/L +V
FG
-VAC/N
CaseNo.926Unit:mm
AMBIENTTEMPERATURE( )
LOAD(%)
LOAD(%)
20
40
60
80
100
INPUTVOLTAGE(VAC)60Hz
90
180
95
190
100
200
115
230
130
260
90
100
80
70
60
50
40
-20 0 10 20 30 40 50 60 70
RSConnector(CN4):JST B-XHorequivalent
PinNo.
1
2
Assignment
+S
-S
MatingHousing
JST XHP
orequivalent
Terminal
JST SXH-001T
orequivalent
230/115VAC
8.2
10
1
2
3
4-M3
11 220
220 16
247
20
30
30
20
63.5
1
2
3
4
5
6
13
10
127
I/P
O/P
Topview
Bottomview
+Adj.
RS -
+
CN4
RS -
+
4-M3
110 8.5
7.5 137 76
5-M3L=6
32 207.5
11.5 18
5V
Other
Airflow
direction
600WSingleOutputPowerSupply SE-600 series