0
BCD.00142 Rev. AA, 17-July-12 Page 5 of 18
www.power-one.com
LPM616 AC-DC Modular Power Supply Data Sheet
5V, 12V, 24V & 48V Single-Output Modules
6. EMC specifications
6.1 EMC Immunity
PARAMETER CONDITIONS / DESCRIPTION CRITERION
Electrostatic Discharge
(ESD)
IEC/EN61000-4-2; GR-1089 R2-1, R2-2, R2-3
Level 4: contact: ±8 kV, air: ± 15kV Perform, criterion B
RF Susceptibility
IEC/EN 61000-4-3;
Level 3: 10 V/m; 80 MHz to 1000 MHz;
AM 80%, 1 kHz radiated; RF electromagnetic field
Perform, criterion A
Fast transient / burst
IEC/EN 61000-4-4; Level 3; ±2 kV, 5kHz
electrical fast transient / burst immunity test Perform, criterion B
Surge IEC61000-4-5, level 3; line to earth: ± 2kV, line to line: ± 1kV
surge immunity test Perform, criterion B
RF conducted
disturbance
IEC/EN 61000-4-6; Level 3; GR-108;
10V, 0.15 to 80MHz, AM 80%, 1kHz Perform, criterion A
Voltage dips / short
interruptions
IEC/EN 61000-4-11; Voltage dips, interruptions and variations.
(Interpretation: dip below Vi min with Po nom = hold-up time 10
ms)
1a: Dip 30%, 100ms Perform, criterion B
1a: Dip 30%, 200ms Perform, criterion B
1a: Dip 60%, 10ms Perform, criterion A
1a: Dip 60%, 100ms Perform, criterion B
1a: Dip >95%, 10ms (interruption) Perform, criterion A
1a: Dip >95%, 100ms (interruption) Perform, criterion B
6.2 EMC Emission
PARAMETER CONDITIONS / DESCRIPTION CRITERION
Conducted Emission
EN55022, FCC
EN 55022, FCC – EN 55022, and CISPR 22 Class B,
FCC 47CFR15 unintentional radiators; standalone at all nominal
input voltages and measured in Po1: 0, 50%, 100%;
signal connections open
Class B;
min. 3dB/µV margin
Radiated Emission
EN55022, FCC
EN 55022, FCC – EN 55022, and CISPR 22 Class B,
FCC 47CFR15 unintentional radiators; standalone at all nominal
input voltages and measured in Po1: 0, 50%, 100%;
signal connections open
Radiated Class B QSP / AVG
min. 3 dB margin
Input Current
Harmonics
EN 61000-3-2, sine wave input, Class D; measured standalone
at all Vin nominal at power levels between 0 and rated Pass