June 2015
Multilayer Low Pass Filter
For 470-770MHz
DEA160710LT-5023B1
1.6x0.8mm [EIA 0603]*
* Dimensions Code JIS[EIA]
RF Components
Caution
Theproductsinthiscatalogwillbeorhavebeen
stoppedproduction
DiscontinueIssueDate Sep. 20, 2019
LastPurchaseOrderDate Sep. 30, 2020
LastShipmentDate Dec. 31, 2020
PleaserefertoourWebsiteaboutreplacementinformation.
RF Components
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150601 / rf_lpf_dea160710lt-5023b1_en.fm20150601 / rf_lpf_dea160710lt-5023b1_en.fm
Multilayer Low Pass Filter
For 470-770MHz
SHAPES AND DIMENSIONS
RECOMMENDED LAND PATTERN
DEA160710LT-5023B1
Conformity to RoHS Directive
Dimensions in mm
1 IN
2 GND
3 OUT
4 GND
Terminal functions
(2)
(4)
(3)(1)
0.45max.
1.60±0.15
0.8±0.10
Marking
[Top view]
[Bottom view]
0.15±0.10
0.45±0.10
0.70±0.10
0.30±0.10
0.15±0.10
0.60 0.300.50
2.20
0.40
0.50
Dimensions in mm
0.50
1.40
RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://product.tdk.com/en/environment/rohs/
Theproductswillbeorhavebeen
stoppedproduction
RF Components
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150601 / rf_lpf_dea160710lt-5023b1_en.fm20150601 / rf_lpf_dea160710lt-5023b1_en.fm
DEA160710LT-5023B1
ELECTRICAL CHARACTERISTICS
Ta: +25±5°C
TEMPERATURE RANGE
Item Frequency Range
(MHz) Min. Typ. Max.
Insertion Loss (dB)
470 to 600 0.76 1.0
600 to 710 1.49 2.0
710 to 770 3.09 4.0
Return Loss (dB) 470 to 710 11.73 13.6
710 to 770 7.36 11.0
Attenuation (dB)
880 to 915 25 33.4
940 to 960 25 29.9
1429 to 1453 27 33.6
1920 to 1980 26 30.7
2400 to 2500 26 33.0
Characteristic Impedance (:)50 (Nominal)
Operating temperature Storage temperature
°C °C
–40 to +85 –40 to +85
Theproductswillbeorhavebeen
stoppedproduction
RF Components
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150601 / rf_lpf_dea160710lt-5023b1_en.fm20150601 / rf_lpf_dea160710lt-5023b1_en.fm
DEA160710LT-5023B1
FREQUENCY CHARACTERISTICS
INSERTION LOSS ATTENUATION
RETURN LOSS
300 700 900500
Frequency(MHz)
8.0
4.0
5.0
3.0
6.0
7.0
2.0
1.0
0.0
Insertion Loss(dB)
20
10
0
60
50
40
30
500 60002500 45001500 3500 55002000 40001000 3000 5000
Attenuation(dB)
Frequency(MHz)
300 700 900500
Frequency(MHz)
–10
–5
30
25
15
20
10
5
0
Return Loss(dB)
Theproductswillbeorhavebeen
stoppedproduction
RF Components
All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications.
RECOMMENDED REFLOW PROFILE
t3 : Time within 5°C of actual peak temperature
The maximum number of reflow is 3.
Preheating Soldering
Critical zone (T3 to T4) Peak
Temp. Time Temp. Time Temp. Time
T1 T2 t1 T3 t2 T4 t3
150°C 200°C 60 to 120sec 217°C 60 to 120sec 240 to 260°C 30sec max.
t3
t1
Preheating
t2
Soldering
T3 T3
T4
T2
T1
t: Time
T: Temperature
Peak
6°C/sec
or lower
3°C/sec
or lower
Theproductswillbeorhavebeen
stoppedproduction
RF Components
• All specifications are subject to change without notice.
• Before using these products, be sure to request the delivery specifications.
20150601 / rf_lpf_dea160710lt-5023b1_en.fm20150601 / rf_lpf_dea160710lt-5023b1_en.fm
REMINDERS FOR USING THESE PRODUCTS
Before using these products, be sure to request the delivery specifications.
SAFETY REMINDERS
Please pay sufficient attention to the warnings for safe designing when using these products.
The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equipment,
home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment,
industrial robots) under a normal operation and use condition.
The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality
require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person
or property.
Please understand that we are not responsible for any damage or liability caused by use of the products in any of the applications below
or for any other use exceeding the range or conditions set forth in this catalog.
(1) Aerospace/Aviation equipment
(2) Transportation equipment (cars, electric trains, ships, etc.)
(3) Medical equipment
(4) Power-generation control equipment
(5) Atomic energy-related equipment
(6) Seabed equipment
(7) Transportation control equipment
(8) Public information-processing equipment
(9) Military equipment
(10) Electric heating apparatus, burning equipment
(11) Disaster prevention/crime prevention equipment
(12) Safety equipment
(13) Other applications that are not considered general-purpose
applications
When using this product in general-purpose applications, you are kindly requested to take into consideration securing protection circuit/
equipment or providing backup circuits, etc., to ensure higher safety.
REMINDERS
Theproductswillbeorhavebeen
stoppedproduction