Rotary Series Specifications Material Mechanical Base & Cover Colour : UL 94V - 0 High-temp Thermoplastic : Black Actuator Colour : UL 94V - 0 High-temp Thermoplastic : White Contact : Alloy Copper with Gold Plated over Nickel Terminal : Brass with Gold Plated Mechanical Life Operating Force : 200m max. 20,000 steps : 200gf-cm max. Environmental Operating Temperature Storage Temperature : -25C to +80C : -40C to +85C Electrical Electrical Life Non-Switching Rating Switching Rating Contact Resistance Insulation Resistance Voltage Proof : 200m max. 20,000 steps : 100mA, 50V DC : 24V DC, 25mA : (a) 100m max. (initial) (b) 200m (final - after test) : 100M min. at 250V DC : 250V AC for 1min. Max 260 255 230 150 Room Temperature 120 ~ 150sec 5 ~ 10sec 60sec Time(sec) Soldering Process Hand Soldering Wave Soldering Reflow Soldering : Use a soldering iron of 30 watts, controlled at (350C) approximately max 5 seconds. : Recommended temperature at 500F (260C) max. 5 seconds. (For through hole type). : When applying reflow soldering,the peak temperature of the reflow oven should be set to 260C max. www.element14.com www.farnell.com www.newark.com Page <1> 12/03/12 V1.0 Rotary Series DIMENSIONS www.element14.com www.farnell.com www.newark.com Page <2> 12/03/12 V1.0 Rotary Series www.element14.com www.farnell.com www.newark.com Page <3> 12/03/12 V1.0 Rotary Series www.element14.com www.farnell.com www.newark.com Page <4> 12/03/12 V1.0 Rotary Series www.element14.com www.farnell.com www.newark.com Page <5> 12/03/12 V1.0 Rotary Series www.element14.com www.farnell.com www.newark.com Page <6> 12/03/12 V1.0 Rotary Series www.element14.com www.farnell.com www.newark.com Page <7> 12/03/12 V1.0 Rotary Series www.element14.com www.farnell.com www.newark.com Page <8> 12/03/12 V1.0 Rotary Series Part Number Table Description Part Number Switch, Rotary, THT, 10x10, 10 POS, 3x2 MCRH2HAF-10R-V-B Switch, Rotary, THT, 10x10, 16 POS, 3x2 MCRH2HAF-16R-V-B Switch, Rotary, THT, 10x10, 10 POS, 3x3 MCRH3HAF-10R-V-B Switch, Rotary, THT, 10x10, 16 POS, 3x3 MCRH3HAF-16R-V-B Switch, Rotary, THT, 10x10, 10 POS, 4x1 MCRH4HAF-10R-V-B Switch, Rotary, THT, 10x10, 16 POS, 4x1 MCRH4HAF-16R-V-B Switch, Rotary, THT, 10x10, 10 POS, 3x2 MCRH2MAF-10R-V-B Switch, Rotary, THT, 10x10, 16 POS, 3x2 MCRH2MAF-16R-V-B Switch, Rotary, THT, 10x10, 10 POS, 3x3 MCRH3MAF-10R-V-B Switch, Rotary, THT, 10x10, 16 POS, 3x3 MCRH3MAF-16R-V-B Switch, Rotary, SMD, 10x10, 10 POS, 3x2 MCRM2HAF-10R-V-B Switch, Rotary, SMD, 10x10, 16 POS, 3x2 MCRM2HAF-16R-V-B Switch, Rotary, SMD, 10x10, 10 POS, 3x3 MCRM3HAF-10R-V-B Switch, Rotary, SMD, 10x10, 16 POS, 3x3 MCRM3HAF-16R-V-B Switch, Rotary, SMD, 10x10, 10 POS, 4x1 MCRM4HAF-10R-V-B Switch, Rotary, SMD, 10x10, 16 POS, 4x1 MCRM4HAF-16R-V-B Switch, Rotary, SMD, 10x10, 10 POS, 3x2 MCRM2MAF-10R-V-B www.element14.com www.farnell.com www.newark.com Page <9> 12/03/12 V1.0 Rotary Series Description Part Number Switch, Rotary, SMD, 10x10, 16 POS, 3x2 MCRM2MAF-16R-V-B Switch, Rotary, SMD, 10x10, 10 POS, 3x3 MCRM3MAF-10R-V-B Switch, Rotary, SMD, 10x10, 16 POS, 3x3 MCRM3MAF-16R-V-B Switch, Rotary, R/A, 10x10, 10 POS, 3x2 MCRV2AF-10R-V-B Switch, Rotary, R/A, 10x10, 16 POS, 3x2 MCRV2AF-16R-V-B Switch, Rotary, R/A, 10x10, 10 POS, 3x3 MCRV3AF-10R-V-B Switch, Rotary, R/A, 10x10, 16 POS, 3x3 MCRV3AF-16R-V-B Switch, Rotary, R/A, 10x10, 10 POS, 4x1 MCRV4AF-10R-V-B Switch, Rotary, R/A, 10x10, 16 POS, 4x1 MCRV4AF-16R-V-B Switch, Rotary, KINK, 10x10, 10 POS, 3x2 MCRS2AF-10R-V-B Switch, Rotary, KINK, 10x10, 16 POS, 3x2 MCRS2AF-16R-V-B Switch, Rotary, KINK, 10x10, 10 POS, 3x3 MCRS3AF-10R-V-B Switch, Rotary, KINK, 10x10, 16 POS, 3x3 MCRS3AF-16R-V-B Switch, Rotary, KINK, 10x10, 10 POS, 4x1 MCRS4AF-10R-V-B Switch, Rotary, KINK, 10x10, 16 POS, 4x1 MCRS4AF-16R-V-B Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. (c) Premier Farnell plc 2012. www.element14.com www.farnell.com www.newark.com Page <10> 12/03/12 V1.0