Product datasheet
Characteristics
XACA03H7
empty pendant control station XAC-A - 3 vertical
openings
Main
Range of product Harmony XAC
Product or component type Pendant control station
Device short name XACA
Complementary
Control station type Double insulated
Enclosure material Polypropylene
Electrical circuit type Control circuit
Enclosure type Empty enclosure
Number of cut-out 3 cut-outs
Control station colour Yellow
Cable entry Rubber sleeve with stepped entry 8…26mm
Guard rail Without
Vertical operator cut-out centre 30mm
Standards UL 508
EN/IEC 60204-32
CSA C22.2 No 14
EN/IEC 60947-5-1
Product certifications CSA
GOST
UL
CCC
Protective treatment TH
Ambient air temperature for operation -25…70°C
Ambient air temperature for storage -40…70°C
Vibration resistance 15 gn (f= 10…500Hz) conforming to IEC 60068-2-6
Shock resistance 100 gn conforming to IEC 60068-2-27
Overvoltage category Class II conforming to IEC 61140
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Jan 25, 2021
1
IP degree of protection IP65 conforming to IEC 60529
IK degree of protection IK08 conforming to EN 50102
Mechanical durability 1000000cycles
Net weight 0.44kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 500g
Package 1 Height 8.5cm
Package 1 width 9cm
Package 1 Length 44.5cm
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Environmental Disclosure Product Environmental Profile
Contractual warranty
Warranty 18 months
2
Product datasheet
Dimensions Drawings
XACA03H7
Dimensions
Below drawing shows a product with 6 cut-outs. Select the number of cut-outs according to the product characteristics in order to get b, b1 and c
dimensions.
(1) For 2 and 3-way XAC A stations.
(2) For 4 to 8-way XAC A stations.
(3) With trigger action Emergency stop head operator
(4) Internal ø
Dimensions in mm
Number of cut-outs 2 3 4 5 6 8 12
b 314 314 440 440 500 560 680
b1 190 190 250 250 310 370 490
c 80 80 80 80 80 80 92
Dimensions in in.
Number of cut-outs 2 3 4 5 6 8 12
b 12.36 12.36 17.32 17.32 19.68 22.05 26.77
b1 7.48 7.48 9.84 9.84 12.20 14.57 19.29
c 3.15 3.15 3.15 3.15 3.15 3.15 3.62