Ordering information Small, Low leakage current type : Screwless terminal type (1-Stage filter) ESM series ESM -10 -000 1 2 3 -O 4 1 Model Name 2 Rated Current 3 Line to ground capacitor code:See table 1.1. R table1.1 Line to ground capacitor code Code 000 101 221 331 471 Line to ground Leakage Current capacitor (Input 125/250V 60Hz) (nominal value) A/ 10 A max Not Provided 5 100pF 12.5 A/ 25 A max A/ 50 A max 220pF 25 330pF 37.5 A/ 75 A max A/100 A max 470pF 50 When the line to ground capacitor code is different, the attenuation characteristic is different. * 4 Options D :DIN rail installation type * The dimensions change when the option is set. Refer to External view. DIN rail installation type is option Electric cable is not appended. Features of ESM series Small, Low leakage current type(1-Stage filter) -Small EMI/EMC Filters that change input-output terminal and protection earth terminal of EA series into screwless terminal type -Single Phase 250VAC -Torque management is unnecessary with screwless Specifications No. 1 Items ESM-03-000 Rated Voltage[V] AC 1f 250 / DC250 ESM-06-000 ESM-10-000 ESM-16-000 6 10 16 2 Rated Current[A] 3 3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity 4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MW min at room temperature and humidity 5 Leakage current 125/250V 60Hz 5 A/10 A max 6 DC resistance 180mW max 7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve) 8 Operating temperature -40 to +85C (Refer to Derating Curve) 9 Operating humidity 20 to 95%RH (Non condensing) 10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing) 11 Vibration 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis 12 Impact 196.1m/s2 (20G), 11ms Once each X, Y and Z axis 13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input) 14 Case size (without projection) /Weight 39X30X85 mm [1.54X1.18X3.35 inches] (WXHXD) /170g max (Option : -D refer to external view) Circuit Diagram 110mW max 40mW max 20mW max Derating Curve Case 1 LINE CY 3 2 CY 4 LOAD Load Factor [%] 100 80 60 40 20 0 -40 CY : Line to ground capacitor : Mounting Plate -30 -20 40 50 55 60 70 80 90 Ambient Temperature [C] EA/ES-6 ESC,ESM,ESP series External view Standard Type 85 [3.35] 78 [3.07] 76.2 24 [0.94] 39 [1.24] [1.04] [1.54] Name Plate 31.5 0.5 [0.31] 7.75 [0.17] Screwless Terminal Input Terminal 2-f4.8 [0.19] Mounting Hole 26.5 Screwless Terminal Output Terminal [2.95] [0.55] 7 0.5 6-Check hole f2.1 [0.08] Protection Earth 14 7 7 Mounting Plate [3] 75 [0.28] [0.28] [0.28] 4.25 Screwless Terminal Input Terminal Screwless Terminal Output Terminal Strip Gauge Protection Earth 6-Connection/release button Weight : 170g max [1.18] Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04] 30 10 12 MAX MIN Strip Tolerance : 1 [0.04] Case : PBT Dimensions in mm, [ ]=inches Refer to instruction manual for details. DIN rail installation Type 8.5 +2 -1 85 [3.35] 78 76.2 [0.08] Protection Earth Screwless Terminal Input Terminal 26.5 [1.04] 24 [0.94] Name Plate [0.55] [0.31] 7.75 [0.17] [1.54] 39 7 Screwless Terminal Output Terminal [3] 6-Check hole f2.1 14 7 7 Mounting Plate [3.07] [0.28] [0.28] [0.28] 4.25 Screwless Terminal Input Terminal [0.33] Screwless Terminal Output Terminal Strip Gauge Protection Earth 6-Connection/release button [1.18] Weight : 170g max 30 10 12 MAX MIN Strip Tolerance : 1 [0.04] Mounting Plate : Iron(surface finishing:nickel plating) t=1.0 [0.04] Case : PBT [0.28] 7 [0.35] (9) Dimensions in mm, [ ]=inches Refer to instruction manual for details. DIN rail Note when installing the EMI/EMC Filter on a DIN rail. When the EMI/EMC Filter is grounded through the DIN rail, the proper noise attenuation may not be achieved. Be sure to connect the protection earth (PE) of the EMI/EMC Filter body to the earth. It can connect the ground to either one only. DIN rail Name Plate EA/ES-8 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cosel: ESM-03-101 ESM-03-101-D ESM-16-000 ESM-16-000-D ESM-03-000 ESM-03-000-D ESM-06-000 ESM-06-000D ESM-10-000 ESM-10-000-D ESM-16-221 ESM-16-221-D ESM-16-331 ESM-16-331-D ESM-16-471 ESM-16471-D ESM-10-331 ESM-10-331-D ESM-10-471 ESM-10-471-D ESM-16-101 ESM-16-101-D ESM-06-471 ESM06-471-D ESM-10-101 ESM-10-101-D ESM-10-221 ESM-10-221-D ESM-06-101 ESM-06-101-D ESM-06-221 ESM-06-221-D ESM-06-331 ESM-06-331-D ESM-03-221 ESM-03-221-D ESM-03-331 ESM-03-331-D ESM-03-471 ESM-03-471-D