Solid-state Timer H3BA-N Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 20), and Safety Precautions (page 16). Solid-state Timer with Valuable Multiple-time Ranges and Multiple-operating Modes * Handles a wide range of applications through six operating modes. * With H3BA-N8H models, the output type can be switched between time-limit DPDT and time-limit SPDT + instantaneous SPDT using a selector. * Setting rings (order separately) to enable consistent settings and to limit the setting range. * Panel Covers (order separately) to enable various panel designs. * Conforms to LR and approved by UL and CSA. RC Broad Line-up of H3B@-N Series H3B@-N H3BA-N Multi-functional Timer 11-pin model H3BA-N 8-pin with H3BA-N8H H3BF-N Twin Timer H3BF-N8 8-pin model H3BG-N H3BH-N Star-delta Timer 8-pin model H3BG-N8 8-pin with H3BG-N8H instantaneous contact output and time-limit output Note: Refer to the H3BF-N/BG-N/BH-N Datasheet (Cat. No. L094-E1-1) for details. Power OFF-delay Timer 8-pin model H3BH-N8 instantaneous contact output Solid-state Timer H3BA-N 1 Model Number Structure Model Number Legend H3BA-N@ 1 1. Number of Pins/Output None: 11-pin models/Time-limit DPDT 8H: 8-pin models/Time-limit SPDT and switchable SPDT (time-limit instantaneous) Ordering Information List of Models Control output Supply voltage Contact output: DPDT (time-limit output) Contact output: Time-limit SPDT and switchable SPDT (time-limit instantaneous) 11-pin models 110 VAC (50/60 Hz) H3BA-N 110 VAC 220 VAC (50/60 Hz) H3BA-N 220 VAC 24 VDC H3BA-N 24 VDC 110 VAC (50/60 Hz) --- 8-pin models --- H3BA-N8H 110 VAC 220 VAC (50/60 Hz) H3BA-N8H 220 VAC 24 VDC H3BA-N8H 24 VDC Accessories (Order Separately) Name/specifications Flush Mounting Adapters Models Y92F-30 Y92F-70 Y92F-71 Mounting Tracks 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Protective Cover Y92A-48B Track Mounting/ Front Connecting Sockets 8-pin P2CF-08 11-pin P2CF-11 Back Connecting Sockets 8-pin P3G-08 11-pin P3GA-11 Setting a specific time Y92S-27 Limiting the setting range Y92S-28 Light gray (5Y7/1) Y92P-48GL Black (N1.5) Y92P-48GB Medium gray (5Y5/1) Y92P-48GM For PL08 Socket Y92H-1 For PF085A Socket Y92H-2 Time Setting Ranges Panel Covers (See note 1.) Hold-down Clips (See note 2.) Note: 1. The Time Setting Ring and Panel Cover are sold together. 2. Hold-down Clips are sold in sets of two. 2 Solid-state Timer H3BA-N Specifications General Item H3BA-N H3BA-N8H A: ON-delay H: ON-delay with instantaneous output contact Operating mode A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval Pin type 11-pin 8-pin Input type No-voltage input --- Output type DPDT (time-limit) SPDT (time-limit) and switchable SPDT (time-limit <---> instantaneous) Mounting method DIN track mounting, surface mounting, and flush mounting Approved standards UL508, CSA C22.2 No.14, Conforms to LR (currently under application and approval is expected by the end of Feb. 2006) Time Ranges Time unit Setting s (sec) min x 10 h (10 h) h (hrs) 1.2 0.05 to 1.2 0.12 to 1.2 1.2 to 12 3 0.3 to 3 3 to 30 12 1.2 to 12 12 to 120 30 3 to 30 30 to 300 Ratings Item H3BA-N Rated supply voltage (See notes 1 and 2) 110 VAC (50/60 Hz), 220 VAC (50/60 Hz), 24 VDC Operating voltage range (See note 3) 85% to 110% of rated supply voltage Power reset Minimum power-opening time: 0.1 s No-voltage input ON impedance: 1 k max. ON residual voltage: 1 V max. OFF impedance: 200 k min. Power consumption 110 VAC: Approx. 4.6 VA (1.5 W) 220 VAC: Approx. 7.9 VA (1.3 W) 24 VDC: Approx. 0.6 W Control outputs Contact: H3BA-N8H 110 VAC: Approx. 3.6 VA (1.6 W) 220 VAC: Approx. 5.4 VA (1.4 W) 24 VDC: Approx. 0.9 W 5 A at 250 VAC, resistance load (cos = 1) Note: 1. DC ripple rate: 20% max. 2. Models other than 24-VDC H3BA-N models cause an inrush current. Pay careful attention when attempting to turn on power to such models with non-contact output from a device such as a sensor. 3. 90% or higher if the Timer is used continuously at a high ambient temperature. Solid-state Timer H3BA-N 3 Characteristics Item H3BA-N H3BA-N8H Accuracy of operating time 0.3% FS max. ( 0.3%10 ms in a range of 1.2 s) Setting error 5% FS 0.05 s max. Reset time Min. power-opening time: 0.1 s max. Min. pulse-input time: 50 ms Influence of voltage 0.5% FS max. ( 0.5%10 ms in a range of 1.2 s) Influence of temperature 2% FS max. (2%10 ms in a range of 1.2 s) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit 1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other (750 VAC for H3BA-N8H) Impulse withstand voltage 1 kV (between power terminals) 2 kV (between current-carrying terminal and exposed non-current-carrying metal parts, 1.5 kV for 24-VDC models) Noise immunity AC models: 1.5 kV (between power terminals), and 600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) DC models: 480 V (between power terminals), and 600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Static immunity Malfunction: 4 kV Destruction: 8 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions Shock resistance Destruction: 1,000 m/s2 (approx. 100G) each in three directions Malfunction: 100 m/s2 (approx. 10G) each in three directions Ambient temperature Operating: -10C to 55C (with no icing) Storage: -25C to 65C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 20 million operations min. (under no load Mechanical: 10 million operations min. (under no at 1,800 operations/h) load at 1,800 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, Electrical: 100,000 operations min. (5 A at 250 resistive load at 1,800 operations/h) VAC, resistive load at 360 operations/h) Case color Light gray (Munsell 5Y7/1) Enclosure ratings IEC: IP40 (panel surface) Weight Approx. 95 g Note: For setting the time-limit of the Timer to a cycle of less than 3 seconds or applying the forced reset, use the H3BA-N in mode D (signal OFFdelay). Nomenclature H3BA-N H3BA-N8H Power Indicator (Green): Lit when Timer operates. PW Output Indicator (Orange): Lit when Timer outputs. Power Indicator (Green): Lit when Timer operates. PW MODE A Operating Mode Selector: Select a mode from A, B, B2, C, D, and E UP 1.5 2 1 2.5 0.5 Time Range Selector: Select one from 1.2, 3, 12, and 30. Operating Mode Display Window Scale Range Display Windows 3 0 Output Indicator (Orange): Lit when Timer outputs. Time Range Selector: Select one from 1.2, 3, 12, and 30. MODE A UP 1.5 4 2 1 2.5 0.5 Output Type Selector: Select a type from A and H A: Time-limit DPDT (default setting) H: Time-limit SPDT and instantaneous SPDT Scale Range Display Windows 3 0 sec sec H3BA H3BA Time setting knob (set time) Output Type Display Window Time Unit Selector Select a unit from sec, min, hrs, and 10h. Solid-state Timer H3BA-N Time setting knob (set time) Time Unit Selector Select a unit from sec, min, hrs, and 10 h. Operation Block Diagrams H3BA-N AC (DC) input Power supply circuit Oscillation circuit Reset input, start input, and gate input Time range/ unit selectors Operating mode selector Counting circuit Output circuit Indicator circuit Input circuit Power-ON Output-ON indicator indicator H3BA-N8H AC (DC) input Power supply circuit Oscillation circuit Time range/ unit selectors Output type selector Counting circuit Output circuit Indicator circuit Power-ON Output-ON indicator indicator Instantaneous output circuit I/O Functions Inputs Outputs Start Starts time-measurement. Reset Interrupts time-measurement and resets time-measurement value. No time-measurement is made and control output is OFF while the reset input is ON. Gate Prohibits time-measurement. Control output Outputs are turned ON according to designated output mode when preset value is reached. Solid-state Timer H3BA-N 5 Basic Setting Using the Setting Ring Setting of Selector Setting a Specific Time The selectors can be turned clockwise and counterclockwise to select the desired time unit, time range, output type (only for H3BAN8H) or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position at which it is secured. Do not set it midway between two securing positions or a malfunction could result from improper setting. Mount the Panel Cover on the Timer, set the desired time with the time setting knob, and place Time Setting Ring A onto the time setting knob so that the time setting notch of Time Setting Ring A is in the center of the reset lock position of the Panel Cover. Time setting Reset lock position notch Operating mode selector/ Output type selector Operating mode/ Output type display window Time setting ring A Panel cover Time setting notch Setting position Groove for screwdriver Selection of Operating Mode with H3BA-N Turn the operating mode selector with a screwdriver until the desired operating mode (A, B, B2, C, D, or E) appears in the display window located above the selector. Selection of Output Type with H3BA-N8H Turn the output type selector with a screwdriver until the desired output type (A or H) appears in the display window located above the selector. Selection of Time Unit and Time Range The desired time unit (sec, min, hrs, or 10h) is displayed in the window below the time setting knob by turning the time unit selector located at the lower right corner of the front panel. A time range (1.2, 3, 12, or 30) is selected with the time range selector at the lower left corner of the front panel, and the selected time range appears (in the window at the lower right part) within the plastic frame of the time setting knob. Example: To set the time to 10 s. Limiting the Setting Range Example: To set a range of 10 and 20 s. Mount the Panel Cover on the Timer, set the time setting knob to 10 s (the lower limit of the setting range), and place Time Setting Ring C onto the time setting knob so that the stopper of Time Setting Ring C is on the right edge of the reset lock position of the Panel cover. Next, set the time setting knob to 20 s (the upper limit of the setting range), place Time Setting Ring B onto the time setting knob so that the stopper of Time Setting Ring B is on the left edge of the reset lock position of the Panel Cover. Stopper Time setting ring B Time range selector Operating mode display window Time unit selector Time unit display window Setting of Time Use the time setting knob to set the desired time. 6 Solid-state Timer H3BA-N Reset lock position Time setting ring C Panel cover Range Timing Chart Note: 1. The minimum power-opening time ("Rt") is 0.1 s and the minimum pulse width is 0.05 s. 2. The letter "t" in the timing charts stands for the set time and "t-a" means that the period is less than the time set. H3BA-N Operating mode Timing chart A: ON-delay t t Power 2 and 10 Basic operation Start 2 and 6 Reset 2 and 7 Power Output relay (NC) 1 and 4 (11 and 8) Start Output relay (NO) 1 and 3 (11 and 9) and output indicator t Output Power indicator B: Flicker OFF start t-a t t t t t Power 2 and 10 Basic operation Start 2 and 6 Reset 2 and 7 Output relay (NC) 1 and 4 (11 and 8) Power Start Output relay (NO) 1 and 3 (11 and 9) and output indicator t t t t t t t Output Power indicator B2: Flicker ON start t-a t t t t t Power 2 and 10 Basic operation Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power Start t Output Power indicator C: Signal ON/OFF-delay t-a t Power 2 and 10 t t-a t t-a t Basic operation Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Power Start t t t t Output Solid-state Timer H3BA-N 7 Operating mode Timing chart D: Signal OFF-delay t-a t-a t t-a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Basic operation Power Start t Output E: Interval t t t-a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Basic operation Power Start t Output Gate Signal Input in Operating Mode A (ON-delay Operation) t1 t2 ON Power OFF ON Start OFF ON Gate OFF ON Reset OFF Output ON relay OFF Note: The set time is the sum of t1 and t2. 8 Solid-state Timer H3BA-N t-a t H3BA-N8H, Output Type: A Type Operating mode Timing chart A: ON-delay Rt t Rt t t-a Power 2 and 7 Output relay (NC) 8 and 5 (1 and 4) Output relay (NO) 8 and 6 (1 and 3) and output indicator Power indicator Basic operation Power t Output H3BA-N8H, Output Type: H Type Operating mode H: ON-delay with instantaneous output contact Timing chart Rt t t Rt t-a Power 2 and 7 Output relay 8 and 5 (NC) Output relay 8 and 6 (NO) (output indicator) Instantaneous 1 and 4 output relay (NC) Instantaneous 1 and 3 output relay (NO) Power indicator Basic operation Power t Output Solid-state Timer H3BA-N 9 Dimensions Note: All units are in millimeters unless otherwise indicated. H3BA-N 15 78 63.7 6 48 0.7 13.6 PW UP 44.8 x 44.8 39 dia. 48 11 pins H3BA-N8H 15 78 6 63.7 48 0.7 13.6 PW UP 44.8 x 44.8 39 dia. 48 8 pins Dimensions with Set Ring 16.5 50 42 dia. 50 Time setting ring Panel cover Dimensions with Y92F-30 Flush Mounting Adapter Panel 58 P3G Back Connecting Socket (sold separately) 52 42 48 Panel Cutout Note: The mounting panel thickness should be 1 to 5 mm. 0.5 R max. 45 +0.6 -0 10 Solid-state Timer H3BA-N 45+0.6 -0 (N)