211 OCTAL 8 & 11 PIN TIME DELAY RELAY C US UL Recognized File No. E43641 C DPDT, 10 AMPS US LISTED 367G IND. CONT. EQ. WHEN USED WITH SOCKETS: 70-464-1(8 PIN) 70-465-1(11 PIN) WIRING DIAGRAM (VIEWED FROM PIN END) (12) (22) 5 4 OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). ON-DELAY OFF-DELAY 1.75 (44.4) 1.75 (44.4) 2.93 (74.4) 0.562 (14.2) (14) 3 (A1) 6 (24) 7 2 8 (21) 1 (11) (A2) COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE 2.37 (60.3) = INTERNATIONAL * IEC ELECTROTECHNICAL COMMISSION 3 4 2 1 TESTING AND EVALUATION * CE PERFORMED BY THE UNDERWRITERS 5 6 8 7 4 3 2 5 6 7 1 11 8 9 10 INPUT ON DELAY EXTERNAL CONTROL SWITCH LABORATORIES AS A THIRD PARTY PARTICIPANT 8 PIN OCTAL 11 PIN OCTAL (22) (12) (14) GENER AL SPECIFICATIONS (@ 25 C ) TIMING Functions Available: UNITS Time Scales: Time Range: Timing Adjustment: % Timing Deviation (mechanical setting): Timing Repeatability % (Constant voltage and temperature): mS maximum Reset Time: mS minimum Input Pulse Length: INPUT Standard Voltage: Input Voltage Tolerance: Power Consumption: Transient Protection: Reverse Polarity Protection: Input Indication: OUTPUT Contact Rating AC Amperes (AC1): Contact Rating DC Amperes (DC1): Contact Rating Horsepower: Contact Rating Pilot Duty: Minimum Load: Contact Material: Output Indication: DIELECTRIC S TRENGTH Across Open Contacts: Input to Contacts: Pole to Pole: TEMPER ATURE Operating, Lower: Operating, Upper: Storage, Lower: Storage, Upper: LIFE EXPECTANC Y EXPECTANCY Electrical Full Load Mechanical @ no Load : MISCELLANEOUS Operating Position: Cover Protection Category: Terminals: Weight: VAC 50/60 Hz VDC maximum VAC 50/60Hz VDC HP @ VAC mW On delay, off delay, interval or one shot 1 0.1 second to 120 minutes KNOB +20 0.1 150 50 10 amps resistive@ 240 10 amps resistive @ 30 1/3 @120, 1/2 @ 240 B300 500 Silver alloy No 1,000 2,500 2,000 C C C C -20 +55 -40 +85 operations operations 100,000 10.000.000 grams Any 40 SOX = 8 pin octal SOX = 11 pin octal 115 9/04 4...12 (A1) + 6 7 (24) 8 (32) 9 (34) 10 1 11 (A2) (11) (31) - INPUT OFF DELAY EXTERNAL SWITCH SHALL NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL COMPONENTS MAY OCCUR . ALTERNATE NEMA OR IEC ( ) NUMBERS VIEWED FROM PIN SIDE See P/N chart 85% to 110%, 80% to 110% 2.5 VA / 2 W Yes Yes No V rms V rms V rms IP THE CLASS 211 TIME DELAY RELAY MAKES USE OF HYBRID CIRCUITRY, COMBINING INTEGRATED CIRCUITS FOR A MULTITUDE OF TIMING FUNCTIONS, AND THE RELIABILITY OF RELAY TECHNOLOGY. 4 3 2 (21) 5 PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com Mating Sockets 70-464-1, 70-750D8-1: SOX, 70-465-1, , 70-750D11-1: SRX See section 7 NOMINAL INPUT VOLTAGE TIMING RANGE ON DELAY, 10 AMP 211ACPSOX-3 W211ACPSOX-5 W211ACPSOX-7 W211ACPSOX-8 W211ACPSOX-60 W211ACPSOX-61 W211ACPSOX-62 W211CPSOX-1 W211CPSOX-3 24 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 24 VDC 24 VDC 1 TO 180 SECONDS 0.1 TO 10 SECONDS 1.0 TO 180 SECONDS 2.0 TO 300 SECONDS 1.0 TO 15 MINUTES 2.0 TO 30 MINUTES 4.0 TO 60 MINUTES 0.1 TO 10 SECONDS 1.0 TO 180 SECONDS OFF DELAY, 10 AMP W211ACPSRX-5 W211ACPSRX-7 W211ACPSRX-8 W211ACPSRX-60 W211CPSRX-1 W211CPSRX-3 120 VAC 120 VAC 120 VAC 120 VAC 24 VDC 24 VDC 0.1 TO 10 SECONDS 1.0 TO 180 SECONDS 2.0 TO 300 SECONDS 1.0 TO 15 MINUTES 0.1 TO 10 SECONDS 1.0 TO 180 SECONDS STANDARD PART NUMBER CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS