Palmswitch,1N/O+1N/C,emergencyswitchingoff,surfacemounting Deliveryprogramme Partno. Articleno. CatalogNo. FAK-R/V/KC11/IY 229748 FAK-R-V-KC11-IY Product range Foot and palm switches Basic function Basic devices Single unit/Complete unit Complete unit Function maintained Description Pull to release Emergency stop pushbutton tamper-proof to ISO 13850/EN 418 Contacts N/O = Normally open N/C = Normally closed 1 N/O 1 NC Notes = safety function, by positive opening to IEC/EN 60947-5-1 Enclosurecolor Colour Enclosure base RAL 9005, black Operator only RAL 1004, yellow yellow Contact sequence Colour Button Red Gehauseoberteil Yellow Gehauseunterteil Black 06/30/2015 229748 - HPL-ED2015 V13.0 EN 1/3 Approval Connection to SmartWire-DT no Technicaldata General Lifespan, mechanical Operations Operating frequency Operations/h Actuating force x 10 6 > 0.1 600 N 40 - 60 Degree of protection, IEC/EN 60529 IP67, IP69K Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature C Open C Mounting position -25 - +40 As required Mechanical shock resistance g > 15 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation In A 6 Heat dissipation per pole, current-dependent Pvid W 0.11 Equipment heat dissipation, current-dependent Pvid W 0 Static heat dissipation, non-current-dependent Pvs W 0 Heat dissipation capacity Pdiss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 40 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Please enquire 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 06/30/2015 229748 - HPL-ED2015 V13.0 EN 2/3 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Low-voltage industrial components (EG000017) / Foot-/palm switch complete (EC000231) Electric engineering, automation, process control engineering / Low-voltage switch technology / Command and alarm device / Foot, palm switch (ecl@ss8.1-27-37-12-17 [AKF035011]) Unlocking method Pull release Colour cap Red Number of contacts as normally open contact 1 Number of contacts as normally closed contact 1 Switching function latching Yes Spring-return No Hole diameter mm Degree of protection (IP) 0 IP67 Approvals Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 012528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Degree of Protection UL/CSA Type 3R, 4X, 12, 13 Dimensions 3 x M20 (PG 13.5) on the side 1 x M16 in the base Additionalproductinformation(links) IL04716006Z(AWA1160-1696)Indicatorlight IL04716006Z (AWA1160-1696) Indicator light ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL04716006Z2011_02.pdf IL04716017Z(AWA1160-1467)Footandpalmswitches IL04716017Z (AWA1160-1467) Foot and palm switches 06/30/2015 ftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL04716017Z2011_02.pdf Eaton Industries GmbH http://www.eaton.eu (c) 06/2015 by Eaton Industries GmbH 229748 - HPL-ED2015 V13.0 EN 3/3