Crouzet Control Relays Control Relays FW Phase Monitor 4 c 22.5 Wide, DIN Rail/Surface Mount c Monitors and Protects Against Phase Loss, Phase Reversal, and Low Voltage c Protection for Three Phase Motors c Level, Current, Voltage Control 793-8400. 84870103. Liquid level, pump up or down, 120 VAC, SPDT ............................................................EACH 793-8402. 84871009. Current control, 0.1 to 10 A, 120 VAC.............................................................................EACH 793-8403. 84871204. Current control, 10 to 100 A, 120 VAC............................................................................EACH 793-8404. 26852304. Transformer for 84871204..............................................................................................EACH 793-8405. 84871102. Current control with attached transformer, 1 to 20 A .....................................................EACH 793-8406. 84872004. Voltage control, 10 to 600 V, 120 VAC............................................................................EACH 54.15 86.00 78.00 21.00 70.00 77.90 c Rugged Construction for Over Voltage and Transients c Economical Motor, Pump and Compressor Protection The FW has a space saving 48 mm wide DIN rail/surface mount enclosure and LED power on and relay status indication. Two front dials provide a nominal voltage setting and a time delay for prevention of nuisance tripping. Output relay is DPDT, 10 amp (resistive). 793-7100. 84873010. 3 230 VAC nominal ......................................................................................................EACH 76.95 793-7102. 84873015. 3 480 VAC nominal ......................................................................................................EACH 76.95 793-7103. 84873016. 3 575 VAC nominal ......................................................................................................EACH 69.00 Control Relays JR Alternating Relays Current Control Relays c Duplex Alternating Control c SPDT or DPDT Output 10 Amp Relay Phase Monitor 793-2009. PJR 110A. 8 pin, SPDT, 110 VAC......................................................................................................EACH 793-2010. PJR 24A. 8 pin, SPDT, 24 VAC/VDC..................................................................................................EACH 793-5529. PJRS 110A. 8 pin, SPDT, 110 VAC with selector switch...................................................................EACH 793-5530. PJRX 110A. 8 pin, SPDT, 110 VAC cross-wired version...................................................................EACH 793-5531. LJR2 110A. 11 pin, DPDT, 110 VAC..................................................................................................EACH 793-5528. LJR2S 110A. 11 pin, DPDT, 110 VAC with selector switch ..............................................................EACH DIRT/LIRT monitors current from 3.5 mA to 7 A VAC and 5 mA to 10 A DC. Purchase transformer (74525305) separately, below. 793-5519. LIRT 110A. 11 pin, 110 VAC..............................................................................................................EACH 66.66 793-5520. DIRT 110A. DIN rail, 110 VAC ...........................................................................................................EACH 73.33 793-5539. 74525305. Transformer.....................................................................................................................EACH 22.04 Monitors phase loss, reversal, unbalance and low voltage. Versions include 8 and 11 pin plug-in and DIN rail mount. For 3 phase 230 VAC and 480 VAC. 793-8102. PWRL 230A. 8 pin, SPDT, 3 230 VAC............................................................................................EACH 62.20 793-8103. PWRL 480A. 8 pin, SPDT, 3 480 VAC............................................................................................EACH 62.20 793-8105. DWRL 230A. DIN rail, SPDT, 3 230 VAC........................................................................................EACH 71.00 793-8106. DWRL 480A. DIN rail, SPDT, 3 480 VAC........................................................................................EACH 68.42 c Selector Switch Version Available c Cross-Wired Version Available 47.35 49.00 56.40 50.70 55.61 55.61 HDU Series Voltage Control Relay and HDI Series Current Control Relay Liquid Level Control Relays Monitors levels of conductive liquid. PNR/PNRU have 4.7 K1/2 to 100 K1/2 sensitivity. NNR has 4.7 K1/2 to 47 K1/2 sensitivity. 793-2011. PNR 110A. 8 pin, 110 VAC, pump down ...........................................................................................EACH 43.23 793-2012. PNRU 110A. 8 pin, 110 VAC, pump up .............................................................................................EACH 47.35 793-2013. NNR 110A. Open PC board, 11 VAC, pump up or down ...................................................................EACH 36.63 CTD 43 and 46 Series Temperature Controllers c c c c c c c c 1/16 Din-Sized Enclosure 5 Temperature Control Modes Multiple Temperature Range (F and C) Auto-Tuning Control of AC/DC Current/Voltage without Memory c Built-In Alarm c Soft Start Function c Nema 4X Front Panel The CTD Series is a temperature controller available in two basic models N the CTD 43 is a single display unit and the CTD 46 is a dual display unit. Both models have a temperature range of 199 to 999 F or 199 to 999C and will accept J, K, L, or N type thermocouples and RTDs as temperature sensors. Control modes include ON-OFF or proportioning action (PID, P, PL, PD). The main output can be programmed for direct (cooling) or inverse (heating) operations and the relay alarm output programmed to 16 different alarm configurations. The auto-tuning OSmartO function will calculate and set automatically the optimum values for the PID mode to insure the closest control of any heating or cooling load. 793-3001. 89421108. CTD 43, Relay output, 110/220 VAC .............................................................................. EACH 793-3000. 89421118. CTD 43, Transistor output, 110/220 VAC........................................................................EACH 793-3002. 89421102. CTD 43, Relay output, 24 VAC/VDC ................................................................................EACH 793-3217. 89421112. CTD 43, Transistor output, 110/220 VAC........................................................................EACH 793-3003. 89422108. CTD 46, Relay output, 110/220 VAC ...............................................................................EACH 793-3215. 89422118. CTD 46, Transistor output, 110/220 VAC........................................................................EACH 793-3216. 89422102. CTD 46, Relay output, 24 VAC/VDC ................................................................................EACH 793-3218. 89422112. CTD 46, Transistor output, 24 VAC/VDC.........................................................................EACH 112 b ALLIED 3 Digit LCD Display Monitors AC and DC Voltages/Current Voltage Control N Type HDUL Measures from 0.2 to 60 V; Type HDUH Measures from 10 to 600 V Current Control N Type HDIL Measures from 2 to 500 mA; Type HDIH Measures from 0.1 to 10 A 214.06 214.06 226.83 226.83 243.40 243.40 271.28 271.28 When the value of the measured current/voltage reaches the threshold, the output relay changes state at the end of a time delay which can be set on the front face at between 0.1 and 3 seconds. Once the current/voltage drops below 5 to 50% of the threshold (hysteresis), the output relay changes state again instantly. Changing the hysteresis therefore does not modify the value of the preset threshold. Control of AC/DC Current/Voltage with Memory When the value of the measured current/voltage reaches the threshold, the output relay changes state at the end of a time delay which can be set on the front face at between 0.1 and 3 seconds and stays locked in this position. Stock No. Mfr.Os Type Type Supply Voltage Measurement Range EACH 793-2600 793-2602 793-2604 793-2606 793-2608 793-2610 84872304 84872306 84872309 84871304 84871306 84871309 HDUL HDUH HDUH HDIL HDIH HDIH 120 VAC 24 VDC 120 VAC 120 VAC 24 VDC 120 VAC 0.2 to 60 V 10.0 to 600 V 10.0 to 600 V 2.0 to 500 mA 0.1 to 10 A 0.1 to 10 A 128.25 135.00 128.25 135.00 135.00 128.25 Products Not Cataloged Are Available N Call 1-800-433-5700 For Price And Delivery