1N5400 - IN5408 Power Diode 1A to 3A, Standard Axial Rectifiers Features: * 3.0 ampere operation at TA = 75C with no thermal runaway. * High current capability. * Low leakage. Ampere General Purpose Rectifiers Absolute Maximum Ratings* Symbol IO TA = 25C unless otherwise noted Parameter Value Average Rectified Current 0.375" lead length at TA = 75C 3.0 PD Peak Forward Surge Current 8.3ms single half-sine-wave Superimposed on rated load (JEDEC method) Total Device Dissipation Derate above 25C RJA Thermal Resistance, Junction to Ambient Tstg Storage Temperature Range TJ Operating Junction Temperature if (surge) Units A 200 6.25 50 W mW/C 20 C/W -55 to +150 C *These ratings are limiting values above which the serviceability of any semiconductor device may be impaired. Electrical Characteristics Parameter TA = 25C unless otherwise noted Device 5400 5401 5402 5404 5406 5407 5408 Peak Repetitive Reverse Voltage 50 100 200 400 600 800 1000 Maximum RMS Voltage 35 70 140 280 420 560 700 DC Reverse Voltage (Rated VR) 50 100 200 400 600 800 1000 Units V Maximum Reverse Current at rated VR TA = 25C TA = 100C 5.0 500 A Maximum Forward Voltage at 3.0A 1.2 V Maximum Full Load Reverse Current, Full Cycle TA = 105C 0.5 mA Typical Junction Capacitance VR = 4.0V, f = 1.0MHz 30 pF Page 1 30/05/05 V1.0 1N5400 - IN5408 Power Diode Typical Characteristics Page 2 30/05/05 V1.0 1N5400 - IN5408 Power Diode Specifications VRRM maximum Voltage If (av) A Ifsm A Plastic Package Part Number 50 1N5400 100 1N5401 200 1N5402 400 3 200 DO-201AD 1N5404 600 1N5406 800 1N5407 1000 1N5408 Page 3 30/05/05 V1.0 1N5400 - IN5408 Power Diode Notes: International Sales Offices: AUSTRALIA - Farnell InOne FINLAND - Farnell InOne NETHERLANDS - Farnell InOne SWITZERLAND - Farnell InOne Tel No: Tel No: Tel No: ++ 61 2 9645 8888 Fax No: ++ 61 2 9644 7898 Fax No: ++ 358 9 345 5411 Fax No: ++ 31 30 241 7333 Tel No: ++ 41 1 204 64 64 Fax No: ++ 41 1 204 64 54 AUSTRIA - Farnell InOne FRANCE - Farnell InOne NEW ZEALAND - Farnell InOne UK - Farnell InOne Tel No: Tel No: Tel No: Tel No: ++ 43 662 2180 680 ++ 358 9 560 7780 ++ 33 474 68 99 99 ++ 31 30 241 7373 ++ 64 9 357 0646 ++ 44 8701 200 200 Fax No: ++ 43 662 2180 670 Fax No: ++ 33 474 68 99 90 Fax No: ++ 64 9 357 0656 Fax No: ++ 44 8701 200 201 BELGIUM - Farnell InOne GERMANY - Farnell InOne NORWAY - Farnell InOne UK - BuckHickman InOne Tel No: Tel No: Tel No: ++ 45 44 53 66 66 ++ 44 8450 510 150 ++ 32 3 475 2810 ++ 49 89 61 39 39 39 Fax No: ++ 32 3 227 3648 Fax No: ++ 49 89 613 59 01 Fax No: ++ 45 44 53 66 02 ++ 44 8450 510 130 BRAZIL - Farnell-Newark InOne HONG KONG - Farnell-Newark InOne Tel No: ++ 852 2268 9888 PORTUGAL - Farnell InOne UK - CPC ++ 55 11 4066 9400 Tel No: ++ 34 93 475 8804 ++ 44 8701 202 530 Fax No: ++ 55 11 4066 9410 Fax No: ++ 852 2268 9899 Fax No: ++ 34 93 474 5288 ++ 44 8701 202 531 CHINA - Farnell-Newark InOne IRELAND - Farnell InOne SINGAPORE - Tel No: Tel No: Tel No: ++86 10 6238 5152 Fax No: ++86 10 6238 5022 Farnell-Newark InOne Tel No: ++ 65 6788 0200 ++ 353 1 830 9277 Fax No: ++ 353 1 830 9016 Fax No: ++ 65 6788 0300 export EXPORT - Farnell InOne Tel No: ++ 44 8701 200 208 Fax No: ++ 44 8701 200 209 For enquiries from all other markets DENMARK - Farnell InOne ITALY - Farnell InOne SPAIN - Farnell InOne Tel No: Tel No: Tel No: ++ 45 44 53 66 44 ++ 39 02 93 995 200 ++ 34 93 475 8805 Fax No: ++ 45 44 53 66 06 Fax No: ++ 39 02 93 995 300 Fax No: ++ 34 93 474 5107 ESTONIA - Farnell InOne MALAYSIA - SWEDEN - Farnell InOne http://www.farnellinone.com Tel No: ++ 358 9 560 7780 Fax No: ++ 358 9 345 5411 Farnell-Newark InOne Tel No: ++ 60 3 7873 8000 Fax No: ++ 60 3 7873 7000 Tel No: ++ 46 8 730 50 00 Fax No: ++ 46 8 83 52 62 http://www.buckhickmaninone.com http://www.cpc.co.uk Disclaimer This data sheet and its contents (the "Information") belong to the Premier Farnell Group (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Multicomp is the registered trademark of the Group. (c) Premier Farnell plc 2004. Page 4 30/05/05 V1.0