FEATURES * 1- or 2-beam floating blanking * Manual or automatic restart * External Device Monitoring (EDM) * 2 or 4 inputs for muting signals * Manual muting override * Input for serial connection of an auxiliary safety device * Unique patented configuration cards for quick set-up and easy replacement * Self-contained with optical synchronisation * 2 static (solid state) safety outputs with short-circuit and cross-fault detection * Muting lamp/diagnosis output or static (solid state) non safety output for signalling * Selection of the infrared emission power allows cross-talk reduction * Enhanced diagnostic information includes the following indication: signal strength, cross-talk, muting, blanking, restart and failure diagnostic * Test input with selectable test input type * Resolutions available: o14 mm / 0.6 in for finger detection o30 mm / 1.2 in for hand detection o50 mm / 1.97 in for leg detection * Protection height up to 1830 mm / 72 in * Scanning range up to 20 m / 65 ft * M12 connectors * Mounting brackets included allowing multiple mounting positions * Safety relay modules for more switching capability (to be ordered separately). TYPICAL APPLICATIONS * Presses and punches * Metal-forming, milling and drilling machines * Spot-welding machines and fine-boring machines * Pressing, moulding and thermoforming machines * Stacking machines, transporting and conveyor technology; handling equipment and assembly lines * Palletizing industry FF-SYB Series FF-SYB Type 4 Safety light curtain Compact, Universal, Smart and Full-featured Approved as Type 4 per IEC/EN 61496-1/2 The Honeywell FF-SYB light curtain is in compliance with IEC/EN 61496 - parts 1 and 2 standard and meets the requirements for a Type 4 Active Optoelectronic Protective Device, the highest level for safety products. The product received an EC type test certificate from the French INRS notified body, required for safety equipment as per the 98/37/EC Machinery Directive. It meets the applicable parts of North American standards and regulations (OSHA 1910.212, OSHA 1910.217, ANSI standards including ANSI RIA 15.06 for Control Reliability and CSA Z434). The CSA marking makes it a product usable in most parts of the world. As soon as an object is detected inside the protection field, the FF-SYB de-energizes its two static (solid state) safety outputs to signal the dangerous motion to stop. The FF-SYB is a self-contained light curtain that does not require a separate control unit for operation. Functions such as floating blanking, muting, external device monitoring, manual restart and serial connection make it a comprehensive product and eliminate the need for additional control modules. These built-in features, combined with the small size of the housing, help users reduce overall cost by saving space and installation time. A unique patented configuration card system allows the user to set up the correct operating mode when swapping units, by simplifying and reducing the number of operations. ! WARNING MISUSE OF DOCUMENTATION * The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as system installation information. * Complete installation, operation and maintenance information is to be referenced for each product. Failure to comply with these instructions could result in death or serious injury. Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 1 External Device Monitoring (EDM) FF-SYB The FF-SYB is fitted with an EDM input which allows users to check the correct state of the final switching devices (relays or contactors with positively guided contacts). After each intrusion into the protection field, the FF-SYB will check that the EDM input loop is closed before switching the outputs back to ON. If the FF-SYB operates in automatic restart mode, it will restart immediately if the EDM loop is closed. If the FF-SYB operates in manual restart mode, it will restart when the restart push-button is pressed and if the EDM loop is closed. If the EDM loop remains open (meaning that the external device has a malfunction) the FF-SYB will keep its outputs open and will not restart. Manual restart The FF-SYB can be used in automatic or manual restart mode. In automatic mode, the outputs will switch back to ON after an interruption of the protection field, as soon as the field becomes clear again. In manual restart mode, the FF-SYB will not switch back its outputs to ON until a manual restart push-button is pressed and released. The push-button must be a normally open type button. The manual restart will not switch the OSSDs back to ON in case of light curtain lock out (internal failure, optical interference, etc.) or when the protection field is still interrupted. Auxiliary output An additional non safety output is available to either mimic the safety output status (solid state Normally Closed signalling output) or signal muting sequences and provide diagnostic information (mode selection depending). Muting function The FF-SYB is fitted with a built-in muting function. Muting is the ability to temporarily inhibit the outputs of a light curtain under certain conditions. Sensors are connected to the light curtain through the main connector. An optional junction box is available to perform the electrical connections close to the location of the muting sensors. Muting sensors are used to discriminate authorised materials from people. The muting sensors must be able to detect the passing material (pallets, vehicles, etc.) according to the material's length and speed. Figure 1 shows an FF-SYB placed on a conveyor, with the corresponding muting sensors. The muting activation sensors temporarily inhibit the FF-SYB light curtain as soon as they detect the object. The outputs of these sensors are connected to the muting inputs of the FF-SYB receiver. Muting sensors must be successively actuated for a correct muting sequence to start. Whenever one of the two muting sensors is released, the muting sequence stops. In case of an incorrect muting sequence, a temporary manual muting (override) procedure may be performed to clear the FF-SYB light curtain detection field and revert back to normal operation. Suitable optoelectronic, mechanical, proximity sensors, etc. can be used as muting sensors. Inputs for muting sensors accept sensors with relay or static (solid state) outputs (NPN or PNP). 2-wire sensors are also accepted. A muting lamp output is available on the FF-SYB receiver to drive an external muting indicator that should be installed in a suitable location on the machine. The following are some configuration examples when using the muting function: Figure 1 - Bi-directional application with two optoelectronic sensors SM 1 FF -SYB Muting sensors connection : 24 Vdc ! Pin 3 SM1 contact HAZARDOUS AREA Pin 4 SM 2 0 Vdc 2 FF-SYB receiver unit M12 connector SM2 contact Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. Figure 2 - Bi-directional application with four photoelectric sensors 2 sensors can be wired in parallel on each of the 2 muting inputs of the light curtain, creating a 4 sensor bi-directional muting. 24 Vdc SM4 SM3 F F -S Y B SM 2 SM1 FF-SYB Muting sensors connection : FF-SYB receiver unit M12 connector SM1 contact ! Pin 3 HAZARDOUS AREA SM3 contact SM2 contact 0 Vdc Pin 4 SM4 contact Figure 3 - Uni-directional application with four optoelectronic sensors Muting sensors connection : EM2 EM1 F F -S Y B SM 2 SM1 24 Vdc FF-SYB receiver unit terminal strip SM1 contact pin 9 ! pin 3 EM1 contact HAZARDOUS AREA SM2 contact 0 Vdc pin 10 pin 4 EM2 contact Note: this mode of operation requires direct connections to the receiver internal terminal strip. A M20 cable gland is delivered with the package. Male M23 cordsets are available on option (see "Accessories" section). Floating blanking function The FF-SYB is fitted with a selectable floating blanking function which allows users to inhibit 1 or 2 beams anywhere within the protection field, except the bottom beam which is used for synchronisation. If 2 beam floating blanking is selected, the interruption of 1 or 2 beams will not lead to the opening of the outputs. The 2 beams can be adjacent or not. It is useful in those applications where material or air ejected parts randomly travel through or within the sensing field. You can also disable light beams in an area where a fixture penetrates the light field, and you can permit stationary objects to protrude into the light curtain's sensing field. Figure 4 light beams straightener coil stock Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 3 When using floating blanking, the resolution of the light curtain is altered according to the following table: FF-SYB Model FF-SYB14 FF-SYB30 FF-SYB50 Resolution without floating/ blanking Resolution with 1-beam floating blanking 14 mm / 0.55 in 30 mm / 1.18 in 50 mm / 1.97 in 24 mm / 0.94 in 50 mm / 1.97 in 90 mm / 3.54 in Resolution with 2-beam floating blanking 34 mm / 1.33 in 70 mm / 2.75 in 130 mm / 5.12 in The maximum size of an undetected object is also affected by floating blanking: Maximum size of undetected object with 2-beam floating blanking 16 mm / 0.63 in 30 mm / 1.18 in 70 mm / 2.75 in Maximum size of undetected object with 1-beam floating blanking 6 mm / 0.23 in 10 mm / 0.39 in 30 mm / 1.18 in Model FF-SYB14 FF-SYB30 FF-SYB50 Serial connection The FF-SYB safety light curtain allows the connection of another safety device with dual outputs through 2 inputs on the receiver unit. The auxiliary safety device can be an electromechanical safety switch or any other safety device with either relay outputs or solid state outputs (for safety reasons, reversed polarity on these two inputs is mandatory, therefore connection of a second FF-SYB light curtain is not possible through these two inputs). Connection is done through the main connector. An optional junction box is available to perform the electrical connections close to the light curtain. Figure 5 a) Serial connection of an FF-SYB safety light curtain with a safety mat b) Serial connection of an FF-SYB safety light curtain with a safety gate switch. FF-SYB Safety light curtain Mechanical fences FF-SYB safety light curtain Safety switch Door Mechanical press Safety mat Note: This mode may be combined with the bi-directional muting mode. This combination of modes requires direct connection to the receiver internal terminal strip. A M20 cable gland is delivered with the package. Male M23 cordsets are available on option (see "Accessories" section). Configuration cards The FF-SYB emitter and receiver are set up by the use of configuration cards, similar to the SIM cards used on mobile phones (see figure below). This simple and elegant method eliminates the use of jumpers or dip switches. No computer is required: settings are done on site, using one of the small configuration cards. If the user needs to use a different configuration from the factory settings, he just needs to select the configuration card which corresponds to the desired settings and install it behind the bottom cap of the emitter or receiver. The selected settings are written on the configuration card and are visible through the transparent front window. Figure 6 ! MUTING Rec No blanking 1 blanking 2 blanking #23 M : Manual M2: Muting 2 L : Muting lamp 1B: 1 blanking MM2L1BP M M2 L 1B P If the FF-SYB needs to be exchanged, the configuration card can be installed in another FF-SYB allowing transfer of settings in a few minutes. 4 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. Cross-talk reduction system FF-SYB The FF-SYB light curtain is based upon an infrared transmission between an emitter unit and a receiver unit. It is a requirement of the IEC/EN 61496-2 standard that if a receiver R2 receives two signals transmitted by two different emitters E1 and E2, the receiver R2 must turn to the alarm state. This happens if the receiver R2 is within the beam aperture angle and within the nominal scanning range of the second emitter E1. The cross-talk detection indicator flickers on the receiver R2 to warn the installer. Figure 7 OFF R1 ON test E Minimum s R ning range (50%) alarm 100% NO E restart muting No blanking 1 blanking 2 blanking Medi um scan R3 canning range (23%) R2 MM2L1BP R Medium scanning range (factory setting) A configuration card is used on the emitter unit for the selection of the adequate emission power. This configuration card can be used to eliminate this cross-talk phenomenon by decreasing the scanning range. The end cap can be easily removed to select a different scanning range. Products are delivered with a medium scanning range (middle position) to minimize cross-talk upon installation. Selectable scanning ranges Figure 8 E R FF-SYB14 1,4 m / 4.6 ft 3 m / 9.8 ft Maximum (factory setting) 6 m / 20 ft FF-SYB30 4,6 m / 15.1 ft FF-SYB50 10 m / 32.8 ft 20 m / 65 ft Minimum Medium 0 R1 R1 R1 R2 R2 R2 R3 R3 R3 alarm alarm alarm test test test 23% NO 50% NO 100% NO Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 5 Test input type Normally open Normally closed (factory setting) 24 Vdc 24 Vdc Fuse Fuse Voltage free contact PNP or (PNP static (solid state) output and NPN static (solid state) output also connectable) PNP or 1 1 FF-SYB emitter 2 (+) O p tio n a l te s t in p u t 4 (-) 4 (-) 3 3 0 Vdc 0 Vdc 24 Vdc 24 Vdc Fuse Fuse 1 1 FF-SYB emitter O p tio n a l te s t in p u t 4 (-) 4 (-) 3 3 NPN or 6 FF-SYB emitter 2 (+) O p tio n a l te s t in p u t 2 (+) 0 Vdc FF-SYB emitter 2 (+) O p tio n a l te s t in p u t FF-SYB Figure 9 NPN or 0 Vdc Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. * Type 4 according to the IEC/EN 61496 - parts 1 and 2 standards * Built-in muting, floating blanking, inputs for serial connection of an auxiliary device, manual restart and EDM * Control of the infrared emission source for cross-talk reduction * Enhanced diagnostic information Dimensions in millimeters / inches, meters / feet, weights in kg / lbs Features Type Nominal scanning range Object detection size (see chapter "Floating blanking function") Angle of divergence Emitting light source (immunity) Supply voltage and power consumption Safety outputs (OSSDs) Output type Switching capability Response time (beam interruption) Response time (Auxiliary Safety Device engaged) Maximum cable length Restart time after power up (after beam actuation) Loads impedance Voltage drop Loads turn-on voltage Protections NC signalling or muting lamp/diagnosis output Output type Switching capability Protections Test input (emitter) (1) Input type External contact type Test loop current (resistance) Protections Restart / EDM input (1) External contact type Max. voltage Muting or serial connection inputs (1) External contact type Maximum cable length Environmental/physical characteristics Temperature range Sealing Vibrations Shocks Bumps Product dimension Connection Material Ordering information Each listing consists of an M12 emitter, an M12 receiver, 2 pairs of right-angle brackets, an end cover equipped with a cable gland, a test rod and a set of configuration cards. Approved as Type 4 per IEC/EN 61496-1/2 FF-SYB Type 4 safety light curtain FF-SYB14 0 m to 6 m / 0 ft to 20 ft 14 mm / 0.55 in FF-SYB30 FF-SYB50 0 m to 20 m / 0 ft to 65 ft 0 m to 20 m / 0 ft to 65 ft 30 mm / 1.18 in 50 mm / 1.97 in 2, 25 % Infrared, pulsed, 880 nm (Sunlight: 20 000 Lux * Lamplight: 15 000 Lux) 24 Vdc (20 %); 5 W max. for the emitter, 5 W max. for the receiver 2 safety static (solid state) outputs (PNP with NO characteristics) with permanent short-circuit and cross-fault detections 350 mA max. at 24 Vdc 22 ms (28 ms for model numbers FF-SYB14128 to FF-SYB14176) 28 ms 100 m / 328 ft (100 nF capacitance) > 1 s (80 ms - without EDM, 150 ms - with EDM) 70 min. / 5 k max. < 2 Vdc 5 V min. on resistive loads / 7 V min. on inductive loads Short-circuits and cross-faults, overloads, reversed polarity, micro-cut-off (10 ms, 100 % voltage drop, 10 Hz) 1 PNP non safety output, NC (signalling contact) or NO (muting/diagnostic indication) 100 mA max. at 24 Vdc Overloads, reversed polarity, micro-cut-off (10 ms, 100 % voltage drop, 10 Hz) Floating input with selectable NO/NC test logic Relay contact, or static (solid state) PNP or static (solid state) NPN (must be activated for at least 20 ms) 13 mA typical (750 max.) 3000 Vdc galvanic insulation, reversed polarity, micro-cut-off (14 ms) Relay contact (must be activated for at least 150 ms and less than 3 s) 29 Vdc Relay contact, or static (solid state) PNP or static (solid state) NPN (automatic recognition) 100 m / 328 ft (no limitation in capacitance) Operating: 0 C to 55 C/32 F to 131 F (95% relative humidity) * Storage: -20 C to 75 C/-4 F to 167 F NEMA 4, 13 and IP 65 IEC/EN 61496-1: 10 to 55 Hz frequency range, 1 octave/min. sweep rate, 0,35 mm 0,05 amplitude, 20 sweeps per axis, for 3 axes IEC/EN 61496-1: 15 G - 11 ms - 3 per axis, for 3 axes IEC/EN 61496-1: 10 G - 16 ms - 1000 per axis, for 3 axes Width: 42 mm (1.65 in); depth: 55 mm (2.16 in); height (2) Emitter: M12/5 pole male receptacle * Receiver: M12/8 pole male receptacle or terminal strip with M20 cable gland (see Figure 10 to determine possible modes of operation for each receiver termination type) Housing: aluminium alloy and (conductive) polycarbonate (end caps) * Front plate: polymethylmethacrylate (PMMA) Notes: (1) Voltage switching (high/low): 11 Vdc min. (I > 6 mA) / 5 Vdc (I > 2 mA); Input current (high/low): 20 mA / 10 mA at 24 Vdc. In compliance with the IEC 61131-2 requirements for type 2 sensors. (2) Refer to emitter and receiver dimensions / weights. FF-SYB M2 Model (see Table 2 page 9) Resolutions 14: o 14 mm / 0.6 in 30: o 30 mm / 1.2 in 50: o 50 mm / 1.97 in Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 7 Figure 10 - Possible modes of operation and corresponding receiver termination type and connection box FF-SYB Card (1) Restart mode #01 Manual Blanking (2) Auxiliary Safety Device Muting (3) Auxiliary output Receiver (4) termination (5) NC signal M12 plug #02 Manual 1-beam NC signal M12 plug #03 Manual 2-beam NC signal M12 plug #04 Automatic NC signal M12 plug #05 Automatic 1-beam NC signal M12 plug #06 Automatic 2-beam NC signal M12 plug yes NC signal M12 plug yes NC signal M12 plug #07 Automatic #08 Automatic 1-beam #09 Automatic 2-beam #10 Manual yes NC signal M12 plug yes NC signal M12 plug #11 Automatic 2 inputs (6) NC signal M12 plug #12 Automatic 2 inputs (6) Muting lamp M12 plug #13 Automatic 4 inputs (6) NC signal Terminal strip #14 Automatic 4 inputs (6) Muting lamp Terminal strip #15 Automatic yes 2 inputs NC signal Terminal strip #16 Automatic yes #17 Manual 2 inputs Muting lamp Terminal strip 2 inputs (6) NC signal M12 plug #18 Manual 2 inputs (6) Muting lamp M12 plug #19 Manual 4 inputs (6) NC signal Terminal strip #2 0 Manual 4 inputs (6) Muting lamp Terminal strip #21 Manual yes 2 inputs NC signal Terminal strip #22 Manual yes 2 inputs Muting lamp Terminal strip #23 Manual 1-beam 2 inputs (6) Muting lamp M12 plug #24 Manual 2-beam 2 inputs (6) Muting lamp M12 plug #25 Manual 1-beam 4 inputs (6) Muting lamp Terminal strip #26 Manual 2-beam 4 inputs (6) Muting lamp Terminal strip #27 Manual 1-beam yes 2 inputs Muting lamp Terminal strip #28 Manual 2-beam yes 2 inputs Muting lamp Terminal strip (1) Factory setting: card #04 (2) Floating blanking 1-beam Model Resolution 2-beam Undetected object size Resolution Undetected object size FF-SYB14 24 mm / 0.94 in 6 mm / 0.23 in 34 mm / 1.33 in 16 mm / 0.63 in FF-SYB30 50 mm / 1.97 in 10 mm / 0.39 in 70 mm / 2.75 in 30 mm / 1.18 in FF-SYB50 90 mm / 3.54 in 30 mm / 1.18 in 130 mm / 5.12 in 70 mm / 2.75 in (3) Muting: either 2 inputs available for the connection of 2 or 4 muting sensors to perform a bi-directional muting function (see page 2 and 3), or 4 inputs available for the connection of 4 sensors to perform a uni-directional muting function (see page 3). (4) Auxiliary output: either a normally closed signalling output of a muting and diagnosis lamp output (see page 2). (5) Receiver termination: some modes require direct connections to the internal receiver terminal strip. The M20 cable gland (delivered with the package) allows the use of a male M23 cordset. (6) Connection boxes are available for the interconnection of all sensors and actuators (see "Accessories" section). 8 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. Model 032 048 064 080 096 334 / 13.1 350 / 13.7 370 / 14.6 494 / 19.4 510 / 20.09 530 / 20.9 654 / 25.7 670 / 26.3 690 / 27.2 814 / 32.07 830 / 32.7 850 / 33.5 974 / 38.3 990 / 39 1010 / 39.8 Protection height (mm / in) (1) FF-SYB14 FF-SYB30 FF-SYB50 Sensing field height (mm / in)(2) FF-SYB14 FF-SYB30 FF-SYB50 Total height (mm / in) (3) M12 emitter or receiver Cable gland receiver only 314 / 12.3 310 / 12.2 290 / 11.4 474 / 18.6 470 / 18.5 450 / 17.7 634 / 24.9 630 / 24.8 610 / 24.03 794 / 31.2 790 / 31.1 770 / 30.3 954 / 37.5 950 / 37.4 930 / 36.6 424 / 16.7 438 / 12.2 584 / 23 598 / 23.5 744 / 29.3 758 / 29.8 904 / 35.6 918 / 36.1 1064 / 41.9 1078 / 42.4 Weight per device (kg / lbs) 0,86 / 1.89 1,14 / 2.5 1,42 / 3.12 1,7 / 3.74 1,98 / 4.35 112 128 144 160 176 1134 / 44.6 1150 / 45.3 1170 / 46.0 1294 / 50.9 1310 / 51.6 1330 / 52.4 1454 / 57.2 1470 / 57.9 1490 / 58.7 1614 / 63.5 1630 / 64.2 1650 / 65.0 1774 / 69.8 1790 / 70.5 1810 / 71.2 FF-SYB Table 2 Table 2 (continued) Model Protection height (mm / in) (1) FF-SYB14 FF-SYB30 FF-SYB50 Sensing field height (mm / in)(2) FF-SYB14 FF-SYB30 FF-SYB50 Total height (mm / in) (3) M12 emitter or receiver Cable gland receiver only 1114 / 43.8 1110 / 43.7 1090 / 42.9 1274 / 50.1 1270 / 50.03 1250 / 49.2 1434 / 56.5 1430 / 56.3 1410 / 55.1 1594 / 62.8 1590 / 62.6 1570 / 61.8 1754 / 69.1 1750 / 68.9 1730 / 68.1 1224 / 48.2 1238 / 48.7 1384 / 54.5 1398 / 55 1544 / 60.8 1558 / 61.3 1704 / 67.1 1718 / 67.6 1864 / 73.4 1878 / 73.9 Weight per device (kg / lbs) 2,26 / 4.97 2,54 / 4.97 2,82 / 6.20 3,10 / 6.82 3,38 / 7.43 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 9 Figure 11 - Dimensions in mm / in M12 emitter or receiver Cable gland receiver FF-SYB 34,8/1.37 2,5/0.09 D 54,7/2.15 P 12/0.47 5,6/0.22 oR 42/1.65 Test rod Total height (3) Sensing field height (2) A Protection height (1) Total height (3) Protection height (1) Sensing field height (2) Test rod B Test rod Test rod 16,6 / 0.65 8,84 / 0.34 17,25 /0.67 (1) Protection Height for the minimum detected object size or resolution (2) Sensing Field Height (full screen height) (3) Total Height (including male receptacles or cable gland) Table 1 (mm / in) FF-SYB14 FF-SYB30 FF-SYB50 10 oR (resolution) o 14 / 0.6 o 30 / 1.2 o 50 / 1.97 P (lens pitch) 10 / 0.4 20 / 0.8 40 / 1.57 D (lens diameter) 4 / 0.16 10 / 0.4 10 / 0.39 A (inactive zone) 15,2 / 0.60 22,2 / 0.87 42.2 / 1.66 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. B (inactive zone) 90,6 / 3.56 87,6 / 3.45 87,6 / 3.45 LED status indicators R1 3 scanning range indicators R1, R2, R3 (yellow) R2 FF-SYB Figure 12 - Emitter R3 alarm Alarm indicator (red) test Test indicator (red) Figure 13 - Receiver OFF ON 2 operation indicators (red and green) Signal strength indicator (orange) Cross-talk indicator (red) restart muting Restart indicator (yellow) Muting indicator (orange) 2 blanking indicators (yellow) No blanking 1 blanking 2 blanking Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 11 Wiring FF-SYB Figure 14 - Recommended wiring diagram for a 2-sensor muting application with automatic restart and Temporary Manual Muting (TMM) (see Figure 1) 24 Vdc Fuse Fuse TMM HOLD-TO-RUN DEVICE (3-position spring loaded key switch) (2) Position for key removal TMM hold-to-run device (1) Left (momentary) (+24Vdc) X PNP Right (momentary) NPN X 2 1 FF-SYB emitter Muting lamp Muting 2 (2) 1 3 FF-SYB Receiver Optional tes t input 2 (+) Muting 1 (2) EDM (0 Vdc) 4 2 A1(+) To Engage TMM A3(+) 13 51 23 FF-SRE60292 control module OSSD2 OSSD1 1 To Reset Power 8 Muting inputs automatically recognize the external contact type Y1 ... K1 K2 internal 4 (-) fuse 5 ! Emit Rec #102 A4(-) 14 #12 A : Automatic M2: Muting 2 L : Muting lamp NB: No blanking 50% : scan range NO : test contact 24 52 Y2 A M2 L NB P 50% NO 0 Vdc A2(-) 6 MUTING Dual channel machine control circuit (recommended circuit) 7 3 Figure 15 - Recommended wiring diagram for a 2-sensor muting application with an auxiliary safety device, manual restart and Temporary Manual Muting (TMM) Fuse (+24 Vdc) Fuse TMM HOLD-TO-RUN DEVICE (3-position spring loaded key switch) FF-SYB emitter 1 Muting 2 (2) Left (momentary) 3 (+24Vdc) Right (momentary) X PNP NPN X Serial 2 ( 3) Muting lamp (0 Vdc) ASD Serial 1 (3) 9 FF-SYB Receiver Optional tes t input 2 (+) Muting 1 (2) Restart / EDM 2 1 (2) Position for key removal TMM hold-to-run device (1) 10 OSSD1 2 1 To Reset Power 8 4 A1(+) Muting inputs automatically recognize the external contact type To Engage TMM A3(+) 13 FF-SRE60292 control module OSSD2 23 51 Y1 52 Y2 ... K1 K2 internal 4 (-) fuse 5 7 ! Emit #102 50% : scan range NO : test contact (0 Vdc) 12 50% NO MUTING Rec #22 M : Manual M2+S: Mut2 + Serial L : Muting lamp NB: No blanking M M2+S L NB P 6 A2(-) A4(-) 14 24 Dual channel machine control circuit (recommended circuit) 3 (3) : The Auxiliary Safety Device (ASD) shall have either relay outputs or static (solid state) outputs. In any case, compliance with as shown polarity is mandatory. Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. European EN 999 standard LIGHT CURTAIN MODEL Normal approach FF-SYB14 FF-SYB30 without floating/blanking S 2000 (t1+t2) + 8 (R-14) with S 100 S Hu if S 500, then use: S 1600 (t1+t2) + 850 with Hu 900 mm Hl 300 mm Hl S 1600 (t1+t2) + 8 (R - 14) with S 500 Parallel approach H S Angled approach Hu S Hl FF-SYB30 with 1- or 2 beam floating blanking FF-SYB50 with or without blanking FF-SYB All distances/heights in mm (100 mm = 3.9 in) S 1600 (t1+t2)+(1200 - 0.4H), with H 875 Or S 1600 (t1+t2)+850, with 875 H 1000 with H 15 (R-50): H 300 mm for the FF-SYB30 with 2-beam floating blanking. H 600 mm for the FF-SYB50 with 1-beam floating blanking FF-SYB50 with 2-beam floating blanking not allowed in parallel approach. if 30, then use the normal approach formula, with Hu 900 mm and Hl 300 mm if 30, then use the parallel approach formula, with Hu 1000 mm and Hl 15 (R-50) where R is the light curtain resolution Hi 300 mm for the FF-SYB30 with 2-beam floating blanking Hi 600 mm for the FF-SYB50 with 1-beam floating blanking FF-SYB50 with 2-beam floating blanking not allowed in angled approach. t1: light curtain response time (s) t2: machine stopping time (s) R: light curtain resolution For more information, refer to the EN 999 European standard or comply with the requirements on safety distances given by the type C European standard if existing for the considered machine. Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 13 USA's OSHA/ANSI/RIA standards All distances/heights in inches (1 in = 25,4 mm) FF-SYB LIGHT CURTAIN MODEL FF-SYB14, FF-SYB30, FF-SYB50 with or without floating blanking Normal approach Ds 63 (Ts+Tc+Tr) + Dpf Ds Hl Hu If R 2,5, Dpf = 3.4 x (R - 0.275), (see table below) If Hi 12 and Hu 48 (Typical for Reach Thru), Dpf = 36 If Hi 12 and 36 Hu 48 (Typical for Reach Over), Dpf = 48 If Hi > 12, supplemental safeguarding may be required to detect crawling underneath. Ds 63 x (Ts + Tc + Tr) +48 Parallel approach H 15 x (R-2) Ds H Table for H* FF-SYB14 FF-SYB30 FF-SYB50 No blanking 0 < H 39 0 < H 39 0 < H 39 1-beam 0 < H 39 0 < H 39 23.1 < H 39 2-beam 0 < H 39 11.3 < H 39 Not allowed *If H > 12, supplemental safeguarding may be required to detect crawling underneath. Angled approach Ds Ts: Tc: Tr: Dpf: R: Hl Hu If < 30, then use the normal approach formula If < 30, then use the parallel approach formula worst case stopping time of the machine (s) worst case response time of the machine controls (s) response time of the safety devices (s) Depth penetration factor (in.) light curtain resolution Table for Dpf FF-SYB14 FF-SYB30 FF-SYB50 No blanking 0.935 3.077 5.763 1-beam 2.261 5.763 - For more information, refer to the ANSI/RIA 15.06 American standard. 14 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 2-beam 3.587 - FF-SYB FF-SYZ634178 Kit of 2 right angle mounting brackets with screws, bolts, nuts and washers to mount one emitter or one receiver unit. Possible mounting positions: 1. At the top and the bottom of the FF-SYB (allowing adjustments in azimuth directions of 10). 2. At one of the two lateral dovetail slots (allowing adjustments in vertical directions along the slot) 3. At the rear dovetail slot (allowing adjustments in vertical directions along the slot) Order 2 kits for a complete set of emitter and receiver. (already included in the FF-SYB package) 33,8 / 1.33 33 / 1.30 R2 11,5/0.45 o5,51 / 0.21 25 / 0.98 55 / 2.16 3 38 / 1.49 o5,5/0.21 R2 15/ 0.59 5/ 0.19 37 23,5/ 0.19 52,2 / 2.05 2,5 / 0.09 35 / 1.37 90 Bracket mounting at the top and the bottom Bracket mounting at the lateral dovetail slots 10 10 24,45 / 0.96 54/2.12 M5 dovetail shape bolt 20 / 0.78 o5,2 / 0.20 Bracket mounting at the rear dovetail slots 16,7 / 0.65 1,5 / 0.06 M5 2,4 / 0.09 Accessories 12/ 0.47 9,66 / 0.38 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 15 FF-SYB FF-SYZ634179 Kit of 2 adjustable mounting brackets with rotating plate, screws, bolts, nuts, and washers to mount one emitter or one receiver unit. Possible mounting position is: * at the rear dovetail slot (allowing adjustments in vertical directions along the slot an in azimuth directions of max. 45) Order 2 kits for a complete set of emitter and receiver. Refer to the section FF-SYZ634178 for the detailed dimensions of the brackets. (to be ordered separately as an option, to be mounted together with the FF-SYZ634178 brackets delivered with the FF-SYB package) (x 2) FF-SYZAD Anti-vibration kit Kit of 2 straight brackets and 4 anti-vibration dampers (mounting hardware included) - to substitute for the FF-SYZ634178 brackets delivered with the FF-SYB package. NOTICE (x 4) 16 PROTECTION AGAINST HIGH VIBRATION In case of high vibrations, order: - 2 sets of FF-SYZAD kit for light curtain systems with protection height below 1000 mm/ 39.4 in. - 3 sets of FF-SYZAD kit for light curtain systems with protection height greater or equal to 1000 mm/39.4 in, but less than 1850 mm/72.8in. - 4 sets of FF-SYZAD kit for light curtain systems with protection height greater than 1850 mm/72.8 in. Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. FF-SXZ630170 Pair of fixed posts for FF-SYB light curtain (recommended when mechanical protection of the light curtain is NOT required) To be ordered separately as an option (order 1 piece for a complete FF-SYB emitter/receiver set). FF-SYB Mechanical fixture for muting application FF-SXZ634186 L-shaped extrusion 40 mm x 40 mm / 1.57 in x 1.57 in, 1 m / 3.28 ft long - sensor mounting: o5.5 mm / o1/46 in fixing holes, 100 mm / 3.94 in pitch - rail mounting: 3 pairs of o5.5 mm / o1/46 in fixing holes, 100 mm / 3.94 in pitch, centered To be ordered separately as an option (order 2 pieces for a complete FF-SYB emitter/receiver set). FF-MPZS6018 Muting sensor mounting rails - sensor mounting: o18 mm / o0.71 in mounting holes, 30 mm / 1.18 in distance between centers - rail mounting: o5 mm / o1/5 in fixing holes, 100 mm / 3.94 in pitch To be ordered separately as an option (order 2 pieces for a complete FF-SYB emitter/receiver set). FF-SYZPF Fixed post for FF-SYB light curtain (recommended when the mechanical protection of the light curtain is required) Floorstanding post for the installation of the following FF-SYB light curtains: Light curtain models: FF-SYB032, FF-SYB048, FF-SYB080, FF-SYB096 Multibeam models: FF-SYB02500, FF-SYB03400, FF-SYB04300 To be ordered separately as an option (order 2 pieces for a complete FF-SYB emitter/receiver set). Front covers are available for additional protection of the FF-SYB234 beam access detection systems: FF-SYZ630184-2: Front cover for 2 beams FF-SYZ630184-3: Front cover for 3 beams FF-SYZ630184-4: Front cover for 4 beams To be ordered separately as an option. Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 17 FF-SYB FF-SYZPA Adjustable floor standing post - Compatible with all protection heights - Horizontal, diagonal and vertical adjustment of light curtains possible - Quick mounting and easy light curtain adjustment - 360 rotation of light curtain possible - Fine adjustment of light curtains in azimuth direction of 11 ensures an easy alignment - 700 mm / 27.58 in corner protection for light curtain included - Base plate can be mounted independently - Finish: RAL 1021 yellow paint To be ordered separately as an option. FF-SYZMIR Deflection mirror To be ordered separately as an option Features: Deflection mirror with 10 % scanning range reduction (FF-SYZMIR004 through 18) Deflection mirror with 25 % scanning range reduction (FF-SYZMIR104 through 18) Food and Beverage industry: stainless steel deflection mirrors with 45 % scanning range reduction (FF-SYZMIR204 through 14) Quick mounting and easy mirror adjustment Mounting brackets included (top / bottom mounting) Adjustment of mirror in azimuth direction of 45 Material Aluminium alloy housing Finish Gold colour anodisation Ordering guide: 04 FF-SY032 and FF-SY048 FF-SYZMIR FF-SYZMIR06 FF-SY064 FF-SYZMIR08 FF-SY080 FF-SYZMIR10 FF-SY096 FF-SYZMIR12 FF-SY112 and FF-SY128 FF-SYZMIR14 FF-SY144 FF-SYZMIR16 FF-SY160 FF-SYZMIR18 FF-SY176 FF-SYZPFM Fixed post with plain mirror (10 % or 25 % reduction of scanning range) Floorstanding post with 1 plain mirror (FF-SYZPFM01,10 % of loss) Floorstanding post with 1 plain mirror (FF-SYZPFM11, 25 % of loss) Suitable for light curtain models: FF-SYB032, FF-SYB048, FF-SYB080, FF-SYB096 To be ordered separately as an option. FF-SXZSHL IP67 enclosure for FF-SYB light curtains Enclosures FF-SXZSHL048 FF-SXZSHL096 FF-SXZSHL128 FF-SXZSHLKIT Light curtains FF-SYB032 and 048 FF-SYB064 through 096 FF-SYB112 and 128 Brackets and cable gland kit (order one kit per enclosure) : "P" for polycarbonate, "G" for glass 18 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. For the connection of muting sensors, restart and TMM switches and muting lamp to the light curtain FF-SXZBOX8M12T IP67 junction box, field-attachable home run cable, M12 8-port configuration. FF-SYB M12 connection boxes FF-SXZBOX8M12L02 IP67 junction box, field-attachable home run cable, M12 8-port configuration, prewired with a 2 m/6.56 ft M12 8-pin cordset. Cordsets M12/5 pole M12 single-ended cordset, female / 5-pin straight for the FF-SYB emitter FF-SXZCAM125U02 2 m / 6.56 ft length FF-SXZCAM125U05 5 m / 16.40 ft length FF-SXZCAM125U10 10 m / 32.8 ft length Equivalent to the 805000A09M... Micro-change(R) Series from Brad Harrison (see vendor catalog for color code) 1: brown 2: white 3: blue 4: black 5: green/yellow M12/8 pole M12 single-ended cordset, female / 8-pin straight for the FF-SYB receiver FF-SXZCAM128U02 2 m / 6.56 ft length FF-SXZCAM128U05 5 m / 16.40 ft length FF-SXZCAM128U10 10 m / 32.8 ft length Equivalent to the 808000P02M... Micro-change(R) Series from Brad Harrison (see vendor catalog for color code) 1: white 2: brown 3: green 4: yellow 5: grey 6: pink 7: blue 8: red Cable connector FF-SXZCOM125 - M12 screw connector, female / 5 pin straight for the FF-SYB emitter FF-SXZCOM128 - M12 screw connector, female / 8 pin straight for the FF-SYB receiver Safety control modules FF-SRE60292 Slim line expansion module - 24 Vdc - Safety interface up to Category 4 per EN 954-1 - 4 NO/2 NC safety relay outputs - 22,5 mm / 0.88 in width (to be ordered separately as an option). FF-SRE30812 Expansion module - 24 Vdc, 115 Vac or 230 Vac - Safety interface up to Category 4 per EN 954-1 - 7 NO/1 NC internally redundant safety relay outputs - 90 mm / 3.54 in width (to be ordered separately as an option). Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 19 Safety control modules FF-SYB FF-SRM200P2 Mutual exclusion module (to be ordered separately as an option) - typical applications: loading/unloading chamber on machining centers or conveyors, crossing of conveyor lines, moving conveyors or AGVs - connection of 2 safety devices - 24 Vdc - Category 4 per EN 954-1 - manual start mode, FSD monitoring - crossfault monitoring of inputs - 3 NO safety relay outputs - static outputs for output status and diagnostic information - 45 mm / 1.77 in FF-SRL59022 Presence Sensing Device Initiation (PSDI) (to be ordered separately as an option). - to be used with FF-SYB14 or FF-SYB30 only - accept a single safety light curtain working in a single stroke/dual stroke mode - 24 Vdc - Category 4 per EN 954-1 - manual start mode and FSD monitoring - cross-fault monitoring of inputs - 3 NO safety relay outputs - static outputs for relay output status and diagnostic information - 45 mm / 1.77 in 20 mm / 0.79 in. 75 mm / 2.95 in. 35 mm / 1.38 in. 20 mm / 0.79 in. ac to dc power supply 91 45 m m m /3 97 m / 1.7 .58 m m in. /3 .82 in. 7 in. Muting lamp FF-SXZPWR050 ac to dc power supply (to be ordered separately as an option) - Approvals: UL508 listed, UL1950, cUL/CSA-C22.2 No.950-M90, EN/IEC 60950, EN 50178 (Class 2 Rated for low power installations) - Input voltage: 85-264 Vac (43-67 Hz) - Output voltage: 24-28 Vdc adjustable - Rated continuous load (at 60 C/140 F max.): 2,1 A @ 24 Vdc / 1,8A @ 28 Vdc - Power: 50 W - Dimensions 75 mm x 45 mm x 97 mm / 2.95 in x 1.77 in x 3.82 in - DIN rail mounting - Weight: 240 g / 0.52 lbs FF-SXZMLED Beacon supplied with fixing plate for vertical surface and a LEDs bulb (Telemecanique XVB Series type). To be used as the muting/diagnostic lamp. (not contractual) 3 position spring loaded key switch FF-SXZTMM o 22 mm 3-position spring loaded key switch with a Normally Closed contact on the left position and two complementary (Normally Closed and Normally Open) contacts on the right position (Telemecanique ZB5 Series type, fixing collar with screw clamp contact blocks, key # 455). To be used as the TMM hold-to-run device. (not contractual) 20 Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. Configuration cards FF-SYZ101092E Set of 6 configuration cards for FF-SYB emitter Installation manuals FF-PK107120-EN FF-PK107120-DE FF-PK107120-FR FF-PK107120-IT FF-PK107120-SP One FF-SYB English installation manual One FF-SYB German installation manual One FF-SYB French installation manual One FF-SYB Italian installation manual One FF-SYB Spanish installation manual FF-SYB FF-SYZ101085R Set of 28 configuration cards for FF-SYB receiver NOTICE By default, products will be shipped with the installation manual in the language of the country of delivery when available or in English. If any other language is required, it must be ordered separately. Test rods FF-SYZROD14 Test rod for o14 mm / 0.6 in resolution safety light curtains (already included in the FF-SYB package). FF-SBZROD30 Test rod for o30 mm / 1.2 in resolution safety light curtains (already included in the FF-SYB package). FF-SPZLASER The laser pen FF-SPZLASER is a self-contained and compact laser device designed to ease infrared beam alignments. Its class II conforms to the EN 60825 European standard and the US 21 CFR 1040 American standard. To be ordered separately as an option. FF-SYZ604795 Mechanical adapter for the FF-SPZLASER laser pen to be used with the FF-SYB Series light curtain. To be ordered separately as an option. Safety Products for Machine Safeguarding - (c) 2003 - 2005 Honeywell International Inc. All rights reserved. 21 Warranty and remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. While we provide application assistance, personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. ASIA PACIFIC Control Products Asia Pacific Headquarters Phone: +(65) 6355-2828 Fax: +(65) 6445-3033 Australia Honeywell Limited Phone: +(61) 2-9370-4500 Fax: +(61) 2-9370-4525 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China - PRC - Beijing Honeywell China Inc. Phone: +(86-10) 8458-3280 Fax: +(86-10) 8458-3102 China - PRC - Shanghai Honeywell China Inc. Phone: (86-21) 6237-0237 Fax: (86-21) 6237-1237 China - Hong Kong S.A.R. Honeywell Ltd. Phone: +(852) 2953-6412 Fax: +(852) 2953-6767 Indonesia Honeywell Indonesia Pte Ltd. Phone: +(62) 21-535-8833 Fax: +(62) 21-5367-1008 New Zealand Honeywell Limited Phone: +(64-9) 623-5050 Fax: +(64-9) 623-5060 Toll Free (0800) 202-088 Sales and Service Honeywell serves its customers through a worldwide network of sales offices and distributors. For application assistance,current specifications, pricing or name of the nearest Authorised Distributor, contact a nearby sales office or: INTERNET: www.honeywell.com/sensing E-mail: info.sc@honeywell.com France Honeywell SA Phone: +(33) 1 60 19 80 40 Fax: +(33) 1 60 19 81 73 Philippines Honeywell Systems (Philippines) Inc. Phone: +(63-2) 636-1661/1662 Fax: +(63-2) 638-4013 Singapore Honeywell South East Asia Phone: +(65) 6355-2828 Fax: +(65) 6445-3033 Specifications may change at any time without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Germany Honeywell AG Phone: +(49) 69 8064 444 Fax: +(49) 69 8064 442 Hungary Honeywell Kft. Phone: +(36 1) 451 4300 Fax: +(36 1) 451 4343 South Africa (Republic of) Honeywell Southern Africa Honeywell S.A. Pty. Ltd Phone: +(27) 11 805 1201 Fax: +(27) 11 805 1504 Spain Honeywell S.A. Phone: +(34) 91 313 6100 Fax: +(34) 91 313 6129 Sweden Honeywell AB Phone: +(46) 8 775 55 00 Fax: +(46) 8 775 56 00 Thailand Honeywell Systems (Thailand) Ltd. Phone: +(662) 693-3099 Fax: +(662) 693-3085 Italy Honeywell S.p.A. Phone: +(39) 02 92146 450/ 456 Fax: +(39) 02 92146 490 Switzerland Honeywell AG Phone: +(41) 1 855 24 40 Fax: +(41) 1 855 24 45 Taiwan R.O.C. Honeywell Taiwan Ltd. Phone: +(886-2) 2245-1000 Fax: +(886-2) 2245-3242 The Netherlands Honeywell B.V. Phone: +(31) 20 565 69 11 Fax: +(31) 20 565 66 00 Turkey Honeywell Turkey A.S. Phone: +(90) 216 575 6620 Fax: +(90) 216 575 6637 EUROPE Norway Honeywell A/S Phone: +(47) 66 76 20 00 Fax: +(47) 66 76 20 90 Ukraine Honeywell Phone: +(380) 44 201 44 74 Fax: +(380) 44 201 44 75 Poland Honeywell Sp. zo.o Phone: +(48)606 0964 Fax: +(48)606 0901 United Kingdom Honeywell Control Systems Ltd Phone: +(44) 1698 481481 Fax: +(44) 1698 481676 Portugal Honeywell Portugal Lda Phone: +(351 21) 424 50 00 Fax: +(351 21) 424 50 99 Mediterranean & African Distributors Honeywell SpA Phone: +(39) 2 921 46 232 Fax: +(39) 2 921 46 233 Austria Honeywell Austria GmbH Phone: +(43) 1 727 80 366/246 Fax: +(43) 1 727 80 337 Belgium Honeywell SA/NV India Phone: +(32) 2 728 2522 TATA Honeywell Ltd. Phone: +(91) 20 687 0445/0446 Fax: +(32) 2 728 2502 Fax: +(91) 20 681 2243/687 Bulgaria 5992 Honeywell EOOD Phone: +(359) 2 979 00 23 Japan Fax: +(359) 2 979 00 24 Honeywell Inc Phone: +(81) 3 5440 1425 Czech Republic Fax: +(81) 3 5440 1368 Honeywell spol. s.r.o. Phone: +(420) 242 442 111 South Korea Fax: +(420) 242 442 182 Honeywell Korea Co Ltd Phone: +(822) 799-6167 Denmark Fax: +(822) 792-9013 Honeywell A/S Phone: +(45) 39 55 55 55 Malaysia Fax: +(45) 39 55 55 58 Honeywell Engineering Sdn Bhd Phone: +(60-3) 7958-4988 Finland Fax: +(60-3) 7958-8922 Honeywell OY Phone: +(358) 9 3480101 Fax: +(358) 9 34801375 Romania Honeywell Bucharest Phone: +(40) 21 231 64 37/38 Fax: +(40) 21 231 6439 Commonwealth of Independent States (CIS) Z.A.O. Honeywell Phone: +(7 095) 796 98 36 Fax: +(7 095) 796 98 93 Slovak Republic Honeywell s.r.o. Phone: +(421 2) 58 247 403 Fax: +(421 2) 58 247 415 LATIN AMERICA Honeywell Latin America Headquarters Phone: 1-305-805-8188 Fax: 1-305-883-8257 Argentina Honeywell S.A.I.C. Phone: +(54-11) 4383-3637 Fax: +(54-11) 4325-6470 Brazil Honeywell do Brasil & Cia Phone: +(55-11) 4166-1900 Fax: +(55-11) 4166-1901 Chile Honeywell Chile, S.A. Phone: +(56-2) 425-8400 Fax: +(56-2) 425-8410 Mexico Honeywell S.A. de C.V. Phone: +(52) 55 5081-0200 Fax: +(52) 55 5081-0202 Puerto Rico, Caribbean Honeywell Inc. Phone: +(809) 792-7075 Fax: +(809) 792-0053 Venezuela Honeywell CA Phone: +(58-212) 273-0511 Fax: +(58-212) 273-0599 Middle East Headquarters Honeywell Middle East Ltd. Phone: +(9712) 443 2119 Fax: +(9712) 443 2536 NORTH AMERICA USA/Canada Honeywell Sensing and Control Phone: 1-800-537-6945 1-815-235-6847 Fax: 1-815-235-6545 E-mail: info.sc@honeywell.com This publication does not constitute a contract between Honeywell and its customers. The contents may be changed at any time without notice. It is the customer's responsibility to ensure safe installation and operation of the products. Detailed mounting drawings of all products illustrated are available on request. (c) 2003 - 2005 Honeywell International Inc. All rights reserved. Honeywell 21 Chemin du Vieux Chene 38240 Meylan Cedex France 107119-20-EN FR26 GLO 405 Printed in France www.honeywell.com/sensing