DC/DC CONVERTERS
2401 Stanwell Drive, Concord Ca. 94520 Ph: 925-687-4411 Fax: 925-687-3333 www.calex.com Email: sales @calex.com
6/10/15, eco 160224-3, 180206-1
13S28.75MBH Specifications
Conditions: Ta=25ºC, Vin = 12VDC, unless otherwise noted; not required to operate below 10V.
Input Parameter Conditions Min Typ Max Units
Absolute Maximum Ratings
Input Voltage VDC
Non-Operating Protected from reverse polarity on the input terminals -20 30 VDC
Operating 10 16 VDC
Voltage at ON/OFF input pin 0 30 VDC
Input Characteristics
Operating Input Voltage Range 10 13.2 16 VDC
Maximum Input Current
PO = 2100W @ 10VDC in
223 227 A
Start-up Voltage
VIN
9.5 VDC
Shut Down Voltage
VIN
9.0 VDC
Input Stand-by Current
VIN = 12V, converter disabled
1.25 3 mA
Input No load Current
VIN = 12V, converter enabled
1.25 1.5 A
Output Parameter Conditions Min Typ Max Units
Output Characteristics
Output Voltage Set Point
VIN = 12V, IO = 30.5A
28.0 28.5 30.0 VDC
Output Regulation
Over Line and Load
±80
±120
mV
Total Output Voltage Range Over sample, line, load, temperature & life 27.6 29.3 VDC
Output Voltage Ripple and Noise
Peak to Peak
RMS
20MHz Bandwidth, 10 µF tantalum + 1 µF ceramic
Full Load Resistive
Full Load Resistive
300
60
500
100
mVP-P
mVRMS
Operating Output Current Range 0 75 A
Output DC Current Limit Inception Non-Latching 83 90 105 A
Output DC Current Limit Shutdown Output Voltage at which converter shuts down 22 VDC
Peak Short-Circuit Current Non-Latching, Startup into 10mΩ 140 ADC
Peak Short-Circuit Pulse Duration Non-Latching, Startup into Short 16 ms
RMS Short-Circuit Current Non-Latching, Startup into Short 15 Arms
Dynamic Response
Load Change 37.5A - 67.5A - 37.5A VS=12V, Di/Dt=0.1 a/µs, 6ft. input cable AWG 1/0, 6 ft load cable ±1.9 VDC
Load Change 37.5A - 67.5A - 37.5A VS=12V, Di/Dt=0.1 a/µs, 20ft. input cable AWG 1/0, 6 ft load cable ±2.3 VDC
Load Change 37.5A - 67.5A - 37.5A VS=13.2V, Di/Dt=0.1 a/µs, 6ft. input cable AWG 1/0, 6 ft load cable ±2 VDC
* See Note 2 below for definition of Vs
* See Note 4 for further cable length considerations and dynamic
response
Setting Time To within 1% Vout nom 500 1000 µs
Output Over-Voltage Protection Non-Latching 32.7 34.8 37 VDC
Efficiency
100% Load
50% Load
96.0
96.8
%
%
Note 1: Input and output voltages are measured at input and output terminals of the converter
Note 2: Vs - voltage at external power supply used for testing. VIN < VS due to voltage drop in input cable.
Note 3: All protections are non-latching. Once protection (OVP, OCP, input UVLO) are tripped converter enters into auto restart mode with
500 ms off time.
Note 4: Consult the factory for input cable length and Dynamic Response requirements that differ from the conditions specified above. Some
vehicle applications for DC/DC converters may require cable lengths of up to 30 feet. In such cases the voltage drop caused b y cable
resistance (steady state) and cable inductance during transients must be accounted for to ensure stable operation of the DC/DC
converter. In such cases where additional external capacitance is required for stable operation, it is recommended to add the external
capacitance to the load side of the converter, as this is where most of the transients occur.