PBX Secure Standard83240 Part number 83240023
Dimensions according to standard DIN 41 636 type F
Positive break operation mechanism according to IEC 60947-5-1 Annex K
Double break changeover switch with electrically separated circuits (form Zb)
IP 40 or IP 67 / IP 65 versions
Operating temperature between -50 and +85 °C
Long overtravel
Standard or Low level version
Part numbers
Specifications
Type
Degree of protection mechanism - connection
Connections / Accessories
83240023
Standard83240
IP 40
-
IP 00
W5 + Lever
Direct opening action
Rating nominal / 250 VAC (A)
6
Rating nominal / 250 VDC (A)
0.6
Rating thermal (A)
10
Operatingrange/4→30VDC/AC(A)
-
Maximum operating force (N)
4,5
Minimum positive opening force (N)
28
Maximum rest position (mm)
8,9
Operating position (mm)
6,6
±
0.25
*
Positive opening position (mm)
4,4 *
Maximum end of travel position (mm)
3,4 *
Differential travel (mm)
1
±
0,3
Operating temperature (°C)
-
50→+85
Mechanical life (operations)
107
(IP40)
4x10 6
(IP 67)
Contact gap (mm)
2 x 1
Max. tightening torque (Nm)
1.3 on Ø 4.1 holes
Weight (g)
22 *
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com
Function
Four
-terminal two-way snap-action contact element (form Zb) with positive break operation. The 2 contacts are electrically separated.
N
o
Legend
Fixing screw threaded length
Fixing nuts 2 x M3
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com
4 x M3 screws with saddle
4 x M3 screws with saddle
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com
Thickness : 1 mm
Thickness : 1 mm
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com
Thickness : 1 mm
Thickness : 1 mm
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com
* For IP67 versions used in 125 V DC, please consult us.
N
o
Legend
Number of operations
Current in Amps
N
o
Legend
Number of operations
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com
Current in Amps
Wire outputs, cable outputs
Special levers and actuators
Connections :
- W3 terminals with angle between 0° and 90°
- special add-
on terminals
Special protective cover
UL CSA, CCC, GOST and VDE certification on request
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
28/04/2015 www.crouzet.com