High Performance Amplifier, 29 dB Gain, 10 - 200 MHz AM-/AMC-140
Specifications subject to change without notice.
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
V 5.00
2
Electrical Specifications3,4 TA = -55°C to +85°C Case Temperature
Parameter Test Conditions Frequency Units Min. Typ. Max.
Gain 50 MHz @ +25°C 50 MHz dB 28.3 29.4 30.3
Frequency Response — 10 - 200 MHz dB — — ±1.2
Gain Variation with
Temperature — 10 - 200 MHz dB — — ±1.2
1 dB Compression Output Power 10 - 200 MHz
10 - 70 MHz dBm
dBm +23
+24 —
— —
—
Noise Figure — 10 - 200 MHz dB — — 7.0
Reverse Transmission — 10 - 200 MHz dB — -42 -38
VSWR — 10 - 200 MHz
10 - 70 MHz Ratio
Ratio —
— —
— 2.5:1
2.0:1
Output IP2 Two-tone inputs up to +10 dBm 10 - 200 MHz dBm
+52 —
— —
—
Output IP3 Two-tone inputs up to +10 dBm 10 - 200 MHz
10 - 70 MHz dBm
dBm +36
+40 —
— —
—
Vbias — — V 14.25 15 15.75
Ibias Vbias = +15.0 VDC — mA — 180 220
Power Dissipation @ 15V Bias — W — 2.7 —
Typical Performance Curves
Intermodulation Intercept
Gain vs. Frequency
3. All specifications apply when operated at +15 VDC, with 50 ohms source and load impedance.
4. Heat Sinking: Operation at case temperature above 95°C is not recommended. Heat sinking adequate to dissipate 3.5W must
be provided in use. The flange should be screwed down to the heat sink, which should be RF ground.
28.0
29.0
30.0
31.0
3 5 10 20 50 100 200 300
Frequency (MHz)
Gain (dB)
+85°C +25°C -55°C
60
62
64
66
3 5 10 20 50 100 200 300
Frequency (MHz)
Intercept (dBm)IP2
42
44
46
48
Intercept (dBm) IP3
IP2IP3