Product Data Sheet 8314 HR-197
The engineer's choice
Product Data Sheet 8314 HR-197
5/7/2012 page 2 of 9
8314 HR-197
INDEX
1General ...................................................................................................................................................................... 3
2Mechanics ................................................................................................................................................................. 3
2.1General .............................................................................................................................................................. 3
2.2Connections ....................................................................................................................................................... 3
3Operating Data .......................................................................................................................................................... 4
3.1Operating Data - Electrical Interface - Input ...................................................................................................... 4
3.2Electrical Operating Data ................................................................................................................................... 5
3.3Operating Data - Electrical Interface -Output .................................................................................................... 5
3.4Electrical Features ............................................................................................................................................. 5
3.5Aerodynamic ...................................................................................................................................................... 7
3.6Sound Data ........................................................................................................................................................ 8
4Environment .............................................................................................................................................................. 8
4.1General .............................................................................................................................................................. 8
4.2Climatic requirements*) ...................................................................................................................................... 8
5Safety ......................................................................................................................................................................... 9
5.1Electrical Safety ................................................................................................................................................. 9
5.2Approval Tests ................................................................................................................................................... 9
Product Data Sheet 8314 HR-197
5/7/2012 page 3 of 9
1 General
Fan type Fan
Rotational direction looking at rotor clockwise
Airflow direction Air outlet over flange
Bearing system Ball bearing
Mounting position any
2 Mechanics
2.1 General
Width 52,0 mm
Height 70,0 mm
Depth 40,0 mm
Weight 0,150 kg
Housing material
Impeller material Plastic
2.2 Connections
Electrical connection Special design
details see drawing
Colour Operation
Wire 1 red + UB
Wire 2 black - GND
Product Data Sheet 8314 HR-197
5/7/2012 page 4 of 9
3 Operating Data
3.1 Operating Data - Electrical Interface - Input
Control input None
Product Data Sheet 8314 HR-197
5/7/2012 page 5 of 9
3.2 Electrical Operating Data
Measurement
conditions: Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0: corresp. to free air flow (see section 3.5)
I: corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range p = 0 U 12,0 V 27,0 V
Nominal voltage p = 0 UN 25,0 V
Power consumption p = 0
0001
P
1,5 W 7,1 W 8,6 W
Tolerance +- 17,5 % +- 12,5 % +- 15,0 %
Current consumption p = 0
0001
I
125 mA 284 mA 319 mA
Tolerance +- 17,5 % +- 12,5 % +- 15,0 %
Speed p = 0
0001
n
2.700 1/min 4.900 1/min 5.200 1/min
Tolerance +- 12,5 % +- 7,5 % +- 10,0 %
Starting current
consumption 1.350 mA
3.3 Operating Data - Electrical Interface -Output
Tacho type None
Alarm type None
Electrical Features
Electronic function None
Reversed polarity protection Rectifying diode
Max. residual current at Un IF <= 500 uA
Locked rotor protection Auto restart
Locked rotor current at Un approx. 1.350 mA
Clock signal t3/t4 at locked rotor Typical: 0,6 s / 10 s
Product Data Sheet 8314 HR-197
5/7/2012 page 6 of 9
Product Data Sheet 8314 HR-197
5/7/2012 page 7 of 9
3.5 Aerodynamic
Measurement
conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
a.) Operation condition:
4.900 1/min at free air flow
Max. free-air flow (p = 0 / = max.) 65,0 m3/h
Max. static pressure (p = max. / =0) 142 Pa
Mounted on a traverse. Measured in a aperture plate (Diameter 76,4 mm), wheel in the middle.
Product Data Sheet 8314 HR-197
5/7/2012 page 8 of 9
3.6 Sound Data
Measurement
conditions: Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.5
a.) Operation condition:
4.900 1/min at free air flow
Optimal operating point 62,0 m3/h @ 0 Pa
Sound power level at the optimal operating
point
6,0 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
47,0 dB(A)
Mounted on a traverse. Measured in a aperture plate (Diameter 76,4 mm), wheel in the middle.
4 Environment
4.1 General
Min. permitted ambient temperature TU min. -20 °C
Max. permitted ambient temperature TU max. 70 °C
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 80 °C
4.2 Climatic requirements*)
Humidity requirements humid heat, cyclic; according to DIN EN 60068-2-30,
6 cycle
Water exposure None
Radiation exposure None
Dust requirements Dust check; according to DIN EN 60068-2-68,
6g/m2d, 1 day
Salt fog requirements None
Harmful gas requirements None
*) Permittet application area:
The product is for the use in sheltered rooms with limited controlled temperature. Occasionally condensed water is
allowed. Directly exposure to water must be avoid. Saline ambient conditions must be avoid.
Pollution degree 2 (according DIN EN 60664-1)
It occurs only non-conductive pollution. Occassionally, temporary conductivity caused by condensation occurs.
Product Data Sheet 8314 HR-197
5/7/2012 page 9 of 9
5 Safety
5.1 Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Min.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Sec.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
RI > 10 MOhm
Air and leakage distances 1,0 mm / 1,2 mm
Protection class III
5.2 Approval Tests
CE Yes
UL No
VDE No
CSA No
CCC No
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
ebm-papst:
8314HR-197