DPA Series
• 16 Pin DIP SSR
• Ratings to 1A @ 280 VAC
• SCR output
• Voltage or current-control input
• Zero-crossing (resistive loads) output
PRODUCT SELECTION
Control Voltage
3.5-10 VDC DPA4119 DPA6119
10-35 mA DPA4111 DPA6111
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description DPA41xx DPA61xx
Operating Voltage (47-63Hz) [Vrms] 20-140 20-280
Transient Overvoltage [Vpk] 400 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.01 0.01
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) 500 500
Maximum Load Current [Arms] 1.0 1.0
Minimum Load Current [Arms] 0.025 0.025
Maximum Surge Current (16.6ms) [Apk] 30 30
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.2 1.2
Minimum Power Factor (with Maximum Load) 0.5 0.5
INPUT SPECIFICATIONS (1)
Description DPAxx11 DPAxx19
Control Voltage Range -3.5-10 VDC
Control Current Range 10-35 mA -
Must Turn Off-State Current 1.0 mA -
Must Turn Off-State Voltage -1.0 VDC
Typical Input Current @ 5 VDC -15 mAdc
Nominal Input Impedance -270 Ohm
Maximum Turn-On Time [msec] 1/2 Cycle 1/2 Cycle
Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)( 2) 3750 Vrms
Minimum Insulation Resistance (@ 500 VDC)(2) 109 Ohm
Maximum Capacitance, Input/Output 2.0 pF
Ambient Operating Temperature Range -30 to 80°C
Ambient Storage Temperature Range -30 to 125°C
Weight (typical) 0.1 oz. (2.9g)
Encapsulation Thermally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Dielectric and insulation resistance are measured between input and output
3) Off-State dv/dt test method per EIA/NARM standard RS
MECHANICAL SPECIFICATIONS
PIN 8: AC LOAD
PIN 10: AC LOAD
PIN 16: +DC CONTROL
PIN 1: -DC CONTROL
THERMAL DERATE INFORMATION
AGENCY APPROVALS
UL E116950
CSA LR81689
120210
WIRING DIAGRAM
ANNEX - ENVIROMENTAL INFORMATION