Raychem Tin Plated Copper FTR 16-*-0 Issue 5 5th October 1998 125C, 600/1000 VOLT INSULATED WIRE The complete requirements for procuring the wire described herin shail consist of this document Insulation -' (Thermorad 1602) Fire Retardant Flexible Polyolefin:- Black Conductor - IEC 228 Class 6 Jacket - Fuel and Diesel Resistant Elastomer (FDR 25)-Black Conductor Insulation Jacket Maximum Diameter Nom Diameter Maximum ' Part Number | Max Diameter Resistance (mm) Wall (mm) Weight Number of Strand (mm) @20C | Lower Upper | (mm) | Lower Upper | (kg/km) Strands | Dia. (Q/km) Spec | Target | Spec Spec | Target} Spec (mm) | Min | Max Limit Limit Limit Limit FTR 16-1.5 85 0.16 1.38 | 1.68 12.80 2.80 3.00 3.20 0.50 | 3.80 4.00 4.20 32 FTIR 16-2.5 | 7x20 | 0.16 | 2.20 | 2.60 7.76 3.70 | 3.90 | 4.10 | 0.55 | 4.70 | 5.00 | 5.30 50 FTR 16-4 7x33 0.16 | 265 | 3.15 4.76 4.25 | 4.50 | 4.75 | 0.55 | 5.30 | 5.60 | 5.90 72 FTR 16-6 7x27 0.21 3.35 | 3.85 3.23 4.95 | 5.20 | 545 | 0.55 | 6.00 | 6.30 | 6.60 95 FTR 16-10 | 19x17 | 0.21 4.30 | 4.80 1.88 5.90 | 620 | 650 | 0.65) 7.10 | 7.50 | 7.90 151 FTR 16-16 | 19x27 | 0.21 5.20 | 5.80 1.19 7.10 | 7.40 | 7.70 | 0.70 | 840 | 880 | 9.20 228 FTR 16-25 | 37x21 | 0.21 6.90 | 7.70 0.78 9.00 | 9.30 | 960 ; 0.70 | 10.20 | 10.70 | 11.20 335 FTR 16-35 | 37x30 | 0.21 8.10 | 9.00 0.552 10.30 | 10.60 | 10.90 | 0.75 | 11.50 | 12.10 | 12.70 463 FTR 16-50 | 37x19 | 0.31 9.60 | 10.70 0.39 12.10 | 12.45 | 12.80 | 0.75 | 13.30 | 14.00 | 14.70 631 FTR 16-70 | 37x27 | 0.31 | 11.40 | 12.60 0.272 14.20 | 14.55 | 14.90 | 0.80 | 15.40 | 16.20 | 17.00 878 FTR 16-95 | 37x36 | 0.31 | 13.30] 14.80 0.21 16.60 | 17.00 | 17.40 | 0.90 | 17.90 | 18.80 | 19.70 1170 FTR 16-120 | 37x46 0.31 15.50 | 17.10 0.16 18.95 | 19.40 | 19.85 | 0.95 | 20.30 | 21.30 | 22.30 1481 ADDITIONAL Routine Spark Test to BS 6231 1.5 -16mm? 6kV rms REQUIREMENTS: 25 - 35mm? 10kV rms 50 -120mm? 12kV rms i PERFORMANCE Insulation to be tested and meet the requirements of the issue in effect of Raychem REQUIREMENTS: Specification WCD 51/1602. Outer jacket to be tested and meet the requirements of the issue in effect of Raychem Specification WCD 2002. W & C DESIGN + RED STAMP - CONTROL COPY \ BLACK STAMP - CHECK FOR DESIGN 4 PROD. MAN. TECHNICAL | oA MANUFACTURE LATEST ISSUE Just ee TP LOUS] Niu | Stietaw Sot] 5-10-96 |S 10-W | 5-10-49 [ty Raychem Limited Registration Number: 674709 London, This drawing and the information set forth hereon This specification sheet takes precedence over Faraday Road England ~ are the property of Raychem Ltd. and are to be documents referenced herein. As Raychem Ltd. Dorcan Registered Office: Rolis House held in trust and confidence. Publication, reserve the right to make changes in construction SWINDON 7 Rolts Buildings, Fetter Lane duplication, disclosure or use for any purpose not without notice please contact Raychem Ltd: to ensure SN3 SHH LONDON expressly authorised in writing by Raychem Lid.is _that this document is the latest issue. Tel: (01793) 528171 EC4A 1NH Telex: 449409 prohibited.