CPTC Thermistor:PT Series
Temperature Sensor
THINKING ELECTRONIC INDUSTRIAL Co., LTD. 5 www.thinking.com.tw 2006.07
Reliability Test
Item Standard Test conditions / Methods Specifications
Tensile Strength of
Terminals IEC60068-2-21
Fasten body and apply a force gradually
to each lead for 10±1 sec.
Terminal diameter Force
(mm) T(N)
0.35<d≦0.5 5.0
0.5<d≦0.8 10.0
0.8<d≦1.25 20.0
R/R25 20%∣△ ∣≦
No damage observed
Solderability IEC60068-2-20 Then dip each lead into 255±5 solder℃
for 3±0.5sec.to the 4±1mm above from body .
At least 95% of terminal
electrode is covered by new
solder
Resistance to
Soldering Heat IEC60068-2-20 Dip each lead into 350±10 solder for 3℃~4sec.
to the 4±1mm above body.
R/R25 20% ∣△ ∣≦
No damage observed
Vibration IEC60068-2-6
Fasten body to baseboard with solder perfectly
and supply since wave oscillation at frequency from
10 HZ to 55HZ all oscillation with 0.75 mm of
Vibrato for 24 cycles in each of 3 naturally
perpendicular plane for a total of 6 hours
R/R25 20% ∣△ ∣≦
No damage observed
Shock IEC60068-2-27
Putting the PTC product in the shock equipment
shock wave: half-sine
V=1.0m/s;Acceleration:50m/s2 ;Pulse time:30ms⊿
R/R25 20% ∣△ ∣≦
No damage observed
Climatic sequence IEC60738-1
+40 ,20%R.H X 24hrs →100 X 16hrs→25℃℃℃ X 2hrs→
+40 ,95%R.HX 24hrs→ 0 X 2hrs→+40 ,95%R.HX 24hrs→ ℃℃℃
25 X (1~2)hrs℃
R/R25 20% ∣△ ∣≦
No damage observed
Insulation * CECC42000 100±15VDC , 60±5S 100MΩ≧
Voltage Proof * CECC42000 1000±10Vrms , 60±5S No damage observed
Humidity IEC60068-2-3 40±2 ,℃90~95%RH,12±2VDC* for 1000±2 hrs R/R25 20% ∣△ ∣≦
No damage observed
Temp. cycle IEC60068-2-14 -40±3 ×30min.→+85±2 ×30min ×5Cycles ℃℃
excessive time:2min<T<3min
R/R25 20% ∣△ ∣≦
No damage observed
Endurance at upper
category temperature IEC60068-2-2 Ts+25 , for 1000±2hrs℃ R/R25 20% ∣△ ∣≦
No damage observed
Endurance at
maximum operating
temperature and
maximum voltage
IEC60738-1 Ts+25 , Vmax, Imax for 1000±2 hrs℃ R/R25 20% ∣△ ∣≦
No damage observed
Climatic sequence IEC60738-1
+40 ,20%R.H X 24hrs →100 X 16hrs→25 X 2hrs→ +40 ℃℃℃
,95%R.HX 24hrs→ 0 X 2hrs→+40 ,95%R.H X ℃℃℃
24hrs→25 X (1~2)hrs℃
R/R25 20% ∣△ ∣≦
No damage observed
* : Only application for PTM series