MCC TM Micro Commercial Components Features * * * * * * RS601 omponents 20736 Marilla Street Chatsworth !"# $ % !"# THRU RS607 6 Amp Single Phase Bridge Rectifier 50 to 1000 Volts Low Leakage Low Forward Voltage Any Mounting Position Silver Plated Copper Leads Surge Overload Rating Of 200 Amps UL Recognized File # E165989 RS-6 Maximum Ratings * * A D Operating Temperature: -55C to +125C Storage Temperature: -55C to +150C Microsemi Catalog Number Device Marking RS601 RS602 RS603 RS604 RS605 RS606 RS607 RS601 RS602 RS603 RS604 RS605 RS606 RS607 Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000v Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000v C B A - + E F Electrical Characteristics @ 25C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element IF(AV) 6.0A TA = 65C IFSM 200A 8.3ms, half sine G VF 1.1V IFM = 3.0A; TJ = 25C Maximum DC Reverse Current At IR 10A TA = 25C Rated DC Blocking 1 mA TA = 100C Voltage *Pulse test: Pulse width 300 sec, Duty cycle 1% Revision: 4 H I DIMENSIONS DIM A B C D E F G H I INCHES MIN .895 --.660 .15 x 1.00 .048 .260 .180 .185 www.mccsemi.com MAX .935 .760 .700 .23L --.052 .280 .220 .205 MM MIN 22.70 --16.80 3.8 x 25.40 1.20 6.60 4.60 4.70 MAX 23.70 19.30 17.80 5.57L --1.30 7.10 5.60 5.20 NOTE HOLE TYP 2004/03/01 MCC RS601 thru RS607 Figure 1 Typical Forward Characteristics Figure 2 Typical Reverse Characteristics 100 10 60 6 40 4 20 2 .6 6 .4 4 .2 2 25 C 1 Amps .1 .06 .6 TA=25C .04 .4 .02 .2 .01 .1 .006 .06 .00 4 .04 .002 .02 .01 TA=100C 1 10 Amps TM Micro Commercial Components .001 20 .2 .4 .6 .8 1.0 1.2 40 60 80 100 120 140 1. Volts Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts Figure 3 Forward Derating Curve Figure 4 Peak Forward Surge Current 12 250 10. 200 150 8.0 100 Amps 6.0 Amps 4.0 2.0 0 50 25 0 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 25 50 75 100 125 2 4 6 8 10 20 40 00 60 80 100 Cycles 150 Average Forward Rectified Current - Amperes versus Case Temperature - C Revision: 4 1 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles www.mccsemi.com 2004/03/01