JWS-P Series Single Output Peak Power Industrial Power Supplies Features u 5 Year Warranty u Power factor Corrected u Approved to VDE0160 Machinery Directive u Universal Input (85 - 265VAC) u 200% Peak Power Capability for 10 seconds Key Market Segments & Applications u Factory Automation Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots u Test & Measurement Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection Not recommended for new designs - see HWS series Specifications Model Input Voltage range Inrush Current (100/200VAC) Input Current (Typ) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Remote On / Off AC Power Fail Operating Temperature Storage Temperature Operating Humidity Storage Humidity Cooling Withstand Voltage (1) (1) Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Weight (Typ) Recommended EMI Filter Size (WxHxD) Warranty JWS70P JWS120P JWS240P JWS480P 85 - 265VAC (47 - 63Hz) or 120 - 330VDC A 14 / 28 25 / 50 20 / 40 A 1.0 / 0.5 1.6 / 0.8 3.2 / 1.6 6.4 / 3.2 Meets EN61000-3-2 <0.02%/C >102% V Yes ms 20 mA 0.75 Yes No Yes No Yes -10C~+60C,derate linearly -10C~+65C, derate linearly to 60% load from 50C~60C to 55% load from 50C~65C -30 to +85C 30 - 90% RH 10 - 95% RH Convection Internal Fan Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min >100M at 25C & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 - UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI EN55011 / EN55022-B, FCC Class B, VCCI-B g 700 900 1900 3000 MAW1202-22 MAW1205-22 MB1210 mm Five Years (1) Non condensing 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 11 Disclaimer: us.tdk-lambda.com/lp/legal.htm JWS-P Series Model Selector Voltage Adjust Range JWS70P-24 JWS120P-24 JWS240P-24 JWS480P-24 JWS240P-36 JWS70P-48 JWS120P-48 JWS240P-48 24V 24V 24V 24V 36V 48V 48V 48V 21.6 - 26.4 21.6 - 26.4 21.6 - 28.8 21.6 - 28.8 32.4 - 43.2 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 3 5 10 20 6.65 1.5 2.5 5 6 10 20 40 13.3 3 5 10 192 192 192 192 288 384 384 384 96 96 96 96 144 192 192 192 240 240 240 240 360 480 480 480 80 80 80 80 80 80 80 80 JWS480P-48 48V 43.2 - 52.8 10 20 384 192 480 80 Model Average Peak Ripple Current (A) Current (A) *1 Load Reg (mV) Line Reg (mV) Noise (mV) Efficiency (typ) % Note *1: Peak current for up to 10 seconds with a 50% duty cycle Dimensions Table JWS70P JWS120P JWS240P JWS480P JWS Outline Drawing Height (H) Width (W) Depth (D) 1.97" 2.56" 3.62" 3.62" 3.62" 3.62" 4.72" 6.29" 7.40" 7.80" 7.48" 7.90" W Other Industrial Products HWS JWS & JWT JFS DLP/DSP/DPP H 15 to 1500W Single output 50W to 600W Single and triple output 500W to 2000W Single output 10 to 480W DIN Rail Mount FRONT VIEW For Additional Information, please visit us.tdk-lambda.com/lp/products/jws-series.htm H (BOTH SIDES) SIDE VIEW W MOUNTING SURFACE D See website for detailed drawing. Not recommended for new designs - see HWS series 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 12 Revision A7: Feb 2012