AC-DC Power Supplies Bus Converter . Power Module Type TUNS50F Ordering information TUN 1 S 2 50 3 F *Providing heat sink as option R 05 4 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal Input 5 Output voltage 6 Optional T : with Mounting hole (f3.4 thru) *Avoid short circuit between +BC and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS50F05 50.0 5V 10A TUNS50F12 50.4 12V 4.2A TUNS50F24 50.4 24V 2.1A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT TUNS OUTPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 RIPPLE[mVp-p] -40 to 0C *1 0 to 15% Load*1 0 to +100C*1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to 15% Load*1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] EFFICIENCY[%] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD TUNS50F05 TUNS50F12 TUNS50F24 AC85 - 264 1f (Please refer to the instruction manual, 6.5 Derating) 0.67typ (Io=100%) 0.35typ (Io=100%) 50/60 (47 - 63) 79typ 83typ 84typ 81typ 84typ 86typ 0.95typ 0.90typ Limited by external components (Thermistor) 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) 5 12 24 10 4.2 2.1 10max 24max 48max 10max 24max 48max 80max 120max 120max 120max 150max 150max 200max 280max 380max 120max 150max 150max 200max 200max 250max 280max 360max 460max 50max 120max 240max 100max 240max 480max 20max 40max 90max Fixed (TRM pin open), adjustable by external resistor or external signal 4.50 - 6.00 10.80 - 13.20 21.60 - 26.40 4.97 - 5.13 11.91 - 12.29 23.62 - 24.38 Works over 105% of rating and recovers automatically 6.30 - 7.00 13.90 - 16.35 27.60 - 32.40 Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with IEC61000-3-2 (Class A) *3 58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 80g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1Refer to instruction manual for measuring method of electric characteristics. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Please contact us about another class. TUNS-2 TUNS50F External view Base Plate (Aluminum) Lot No. 25.4 [0.3] [1.0] [0.19] 7.62 (4.7) Name Plate 2- 2.5 48.3 [1.9] Dimensions in : -BC +BC 7.62 7.62 37.3 max AC2 [1.47] [1.1] [0.5] +VOUT 27.9 0.5 TRM AC1 2-M3 Mounting Hole [0.5] 0.2 -VOUT [0.05] 1.27 5- 1 0.1 12.7 [0.5] 2- 2 12.7 [1.9] 7.62 7.62 [0.2] [0.3] [0.3] 48.3 0.5 2- 3.5 25.4 [1.0] [0.3] [2.3] (5.0) 7.62 [0.3] [0.3] 58.4 max 5- 1.5 1.27 [0.05] 5.0 0.5 Case (PBT) [0.2] 12.7 0.5 Recommending size for processing PCB (TOP VIEW) Div. : 0.2inch Tolerance : 0.3 [ 0.012] Weight : 80g max Dimensions in mm, [ ]=inches Mounting hole screwing torque : 0.49N m (5.0kgf mm [inch] cm) max TUNS TUNS-3 AC-DC Power Supplies Bus Converter . Power Module Type TUNS100F Ordering information TUN 1 S 2 100 3 F 4 *Providing heat sink as option R 05 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal Input 5 Output voltage 6 Optional T : with Mounting hole (f3.4 thru) *Avoid short circuit between +BC and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. *If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS100F05 100.0 5V 20A TUNS100F12 100.8 12V 8.4A TUNS100F24 100.8 24V 4.2A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT TUNS OUTPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 RIPPLE[mVp-p] -40 to 0C *1 0 to 15% Load*1 0 to +100C*1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to 15% Load*1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] EFFICIENCY[%] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD TUNS100F05 TUNS100F12 TUNS100F24 AC85 - 264 1f (Please refer to the instruction manual, 6.5 Derating) 1.3typ (Io=100%) 0.7typ (Io=100%) 50/60 (47 - 63) 82typ 83typ 84typ 85typ 85typ 86typ 0.95typ 0.90typ Limited by external components (Thermistor) 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) 5 12 24 20 8.4 4.2 10max 24max 48max 10max 24max 48max 80max 120max 120max 120max 150max 150max 160max 240max 240max 120max 150max 150max 200max 200max 250max 240max 300max 300max 50max 120max 240max 100max 240max 480max 20max 40max 90max Fixed (TRM pin open), adjustable by external resistor or external signal 4.50 - 6.00 10.80 - 13.20 21.60 - 26.40 4.97 - 5.13 11.91 - 12.29 23.62 - 24.38 Works over 105% of rating and recovers automatically 6.30 - 7.00 13.90 - 16.35 27.60 - 32.40 Provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with IEC61000-3-2 (Class A) *3 58.4X12.7X61.0mm [2.3X0.5X2.4 inches] (WXHXD) / 120g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1Refer to instruction manual for measuring method of electric characteristics. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Please contact us about another class. TUNS-4 TUNS100F External view Base Plate (Aluminum) 12.7 0.5 [0.5] Lot No. Case (PBT) 5.0 0.5 [0.2] Recommending size for processing PCB (TOP VIEW) 58.4 max [2.3] 48.3 0.5 (5.0) [0.2] [1.9] 2- 2.5 +VOUT 7.62 5.08 5.08 7.62 7.62 10.16 [0.3] [0.2][0.2] [0.3] [0.3] [0.4] 50.8 [2.0] 61max [0.4] 4- 3.5 -BC 7.62 25.4 [0.3] [1.0] [0.2] 48.3 [1.9] ( 5.1) +BC [0.3] [0.3] +S [2.4] TRM [2.0] AC2 50.8 0.5 [0.5] -S [0.4] -VOUT 10.16 7.62 7.62 10.16 7- 1.5 AC1 12.7 25.4 [1.0] 2- 2 0.2 7- 1 0.1 Name Plate 7.62 [0.3] 4-M3 Mounting Hole Dimensions in : Div. : 0.2inch Tolerance : 0.3 [ 0.012] Weight : 120g max Dimensions in mm, [ ]=inches Mounting hole screwing torque : 0.49N m (5.0kgf mm [inch] cm) max TUNS TUNS-5 AC-DC Power Supplies Bus Converter . Power Module Type TUNS300F Ordering information TUN 1 S 2 300 3 F 4 48 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal Input 5 Output voltage 6 Optional T : with Mounting hole (f3.4 thru) Y1: Outputvoltage adjustment range 20% (Only 48V) R1: with Remote ON/OFF R2: with Remote ON/OFF (Low standby power) R *Avoid short circuit between +BC/R and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. *If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS300F12 300 12V 25A TUNS300F28 308 28V 11A TUNS300F48 312 48V 6.5A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT TUNS OUTPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 RIPPLE[mVp-p] -40 to 0C *1 0 to +100C*1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] EFFICIENCY[%] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF *4 INPUT-OUTPUT-RC INPUT-FG *4 OUTPUT-RC-FG *4 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD TUNS300F12 TUNS300F28 TUNS300F48 AC85 - 264 1f 3.6typ (Io=100%) 1.8typ (Io=100%) 50/60 (47 - 63) 84typ 87typ 87typ 86typ 89typ 90typ 0.96typ 0.93typ Limited by external resistance 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) 12 28 48 25 11 6.5 24max 56max 96max 24max 56max 96max 120max 180max 250max 150max 200max 300max 150max 200max 300max 200max 300max 450max 120max 280max 480max 240max 560max 960max 40max 90max 180max Fixed (TRM pin open), adjustable by external resistor or external signal 9.60 - 14.40 22.40 - 33.60 38.40 - 52.80 (-Y1 Option : 38.4 - 57.6) 11.91 - 12.29 27.56 - 28.44 47.24 - 48.76 Works over 105% of rating and recovers automatically 15.00 - 16.80 35.00 - 39.20 55.20 - 64.80 (-Y1 Option : 60.0 - 67.2) Provided Optional (External power supply is required) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (2015C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1 Complies with IEC61000-3-2 (Class A) *3 117.3X12.7X61.5mm [4.62X0.5X2.42 inches] (WXHXD) / 190g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1Refer to instruction manual for measuring method of electric characteristics. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Please contact us about another class. *4 "RC" is applicable when remote control (optional) is added. TUNS-6 TUNS300F Lot No. Recommending size for processing PCB (TOP VIEW) [0.5] Base Plate (Aluminum) 12.7 0.5 External view 11- 1.5 15 15 [0.59] [0.59] 44.05 [1.73] 4- 3.5 10.2 10 9 3x4=12 [0.4] [0.39] [0.35] [0.47] 50.8 [2.0] 5.0 117.3 max [0.2] 0.5 Case (PBT) [4.62] 106.7 0.5 [4.2] (5.3) 2- 2 0.2 10 10.2 [0.47] [0.35] [0.39] [0.4] 3x4=12 9 [2.42] 61.5 max 0.5 [2.0] 50.8 10 10.2 [0.39] [0.4] [0.21] 2- 2.5 106.7 [4.2] 4 [0.16] 11- 1 0.1 15 15 44.05 [0.59] [0.59] [1.73] Control pin for Remote ON/OFF (Option) [0.16] [0.21] 4 Name Plate (5.35) Dimensions in : 4-M3 Mounting Hole AC1 -VOUT AC2 +VOUT -S +S TRM IOG R +BC -BC RC2 (Option) RC1 (Option) Div. : 0.5inch mm [inch] Tolerance : 0.3 [ 0.012] Weight : 190g max Dimensions in mm, [ ]=inches Mounting hole screwing torque : 0.49N m (5.0kgf cm) max 4-FG TUNS TUNS-7 AC-DC Power Supplies Bus Converter . Power Module Type TUNS500F Ordering information TUN 1 S 2 500 3 F 4 48 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal Input 5 Output voltage 6 Optional T : with Mounting hole (f3.4 thru) Y1: Outputvoltage adjustment range 20% (Only 48V) R1: with Remote ON/OFF R2: with Remote ON/OFF (Low standby power) R *Avoid short circuit between +BC/R and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. *If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS500F12 504 12V 42A (Peak 55A) TUNS500F28 504 28V 18A (Peak 24A) TUNS500F48 504 48V 10.5A (Peak 14A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT TUNS OUTPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] *3 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 RIPPLE[mVp-p] -40 to 0C *1 0 to +100C*1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] EFFICIENCY[%] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF *5 INPUT-OUTPUT-RC INPUT-FG *5 OUTPUT-RC-FG *5 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD TUNS500F12 TUNS500F28 TUNS500F48 AC85 - 264 1f 6.0typ (Io=100%) 3.0typ (Io=100%) 50/60 (47 - 63) 84typ 87typ 88typ 86typ 90typ 90.5typ 0.96typ 0.93typ Limited by external resistance 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) 12 28 48 42 (Peak 55) 18 (Peak 24) 10.5 (Peak 14) 24max 56max 96max 24max 56max 96max 120max 180max 250max 150max 200max 300max 150max 200max 300max 200max 300max 450max 120max 280max 480max 240max 560max 960max 40max 90max 180max Fixed (TRM pin open), adjustable by external resistor or external signal 9.60 - 14.40 22.40 - 33.60 38.40 - 52.80 (-Y1 Option : 38.4 - 57.6) 11.91 - 12.29 27.56 - 28.44 47.24 - 48.76 Works over 101% of peak current and recovers automatically 15.00 - 16.80 35.00 - 39.20 55.20 - 64.80 (-Y1 Option : 60.0 - 67.2) Provided Optional (External power supply is required) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (2015C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1 Complies with IEC61000-3-2 (Class A) *4 117.3X12.7X61.5mm [4.62X0.5X2.42 inches] (WXHXD) / 190g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1Refer to instruction manual for measuring method of electric characteristics. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 ( ) means peak current. Avoid operating with peak current continuously. It may cause failure of the components inside the product. There are limitation of available condition of the peak current, such as peak time, duty etc. (Refer to the instruction manual in detail.) *4 Please contact us about another class. *5 "RC" is applicable when remote control (optional) is added. TUNS-8 TUNS500F Lot No. Recommending size for processing PCB (TOP VIEW) [0.5] Base Plate (Aluminum) 12.7 0.5 External view 11- 1.5 15 15 [0.59] [0.59] 44.05 [1.73] 4- 3.5 10.2 10 9 3x4=12 [0.4] [0.39] [0.35] [0.47] 50.8 [2.0] 5.0 117.3 max [0.2] 0.5 Case (PBT) [4.62] 106.7 0.5 [4.2] (5.3) 2- 2 0.2 10 10.2 [0.47] [0.35] [0.39] [0.4] 3x4=12 9 [2.42] 61.5 max 0.5 [2.0] 50.8 10 10.2 [0.39] [0.4] [0.21] 2- 2.5 106.7 [4.2] 4 [0.16] 11- 1 0.1 15 15 44.05 [0.59] [0.59] [1.73] Control pin for Remote ON/OFF (Option) [0.16] [0.21] 4 Name Plate (5.35) Dimensions in : 4-M3 Mounting Hole AC1 -VOUT AC2 +VOUT -S +S TRM IOG R +BC -BC RC2 (Option) RC1 (Option) Div. : 0.5inch mm [inch] Tolerance : 0.3 [ 0.012] Weight : 190g max Dimensions in mm, [ ]=inches Mounting hole screwing torque : 0.49N m (5.0kgf cm) max 4-FG TUNS TUNS-9 AC-DC Power Supplies Bus Converter . Power Module Type TUNS700F Ordering information TUN 1 S 2 700 3 F 4 *Avoid short circuit between +BC/R and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. *If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S. TUNS700F12 700.8 12V 58.4A -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal Input 5 Output voltage 6 Optional T : with Mounting hole (f3.4 thru) Y1: Outputvoltage adjustment range 20% (Only 48V) R1: with Remote ON/OFF R2: with Remote ON/OFF (Low standby power) P : Parallel operation ( Output voltage variable, Remote sensing disabled) R MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT 48 5 TUNS700F28 700.0 28V 25A TUNS700F48 700.8 48V 14.6A SPECIFICATIONS MODEL VOLTAGE[V] TUNS700F48 POWER FACTOR (Io=100%) INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 RIPPLE[mVp-p] -40 to 0C *1 0 to +100C*1 OUTPUT RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND REMOTE SENSING OTHERS REMOTE ON/OFF TUNS700F12 TUNS700F28 AC85 - 264 1f 8.6typ (Io=100%) 4.1typ (Io=100%) 50/60 (47 - 63) 83typ 86typ 86typ 89typ 0.96typ 0.93typ Limited by external resistance 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) 12 28 58.4 25 24max 56max 24max 56max 120max 180max 150max 200max 150max 200max 200max 300max 120max 280max 240max 560max 40max 90max Fixed (TRM pin open), adjustable by external resistor or external signal 9.60 - 14.40 22.40 - 33.60 11.91 - 12.29 27.56 - 28.44 Works over 105% of rating and recovers automatically 15.00 - 16.80 35.00 - 39.20 Provided Optional (External power supply is required) MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS700F12-P 700.8 12V 58.4A TUNS700F48-P 700.8 48V 14.6A CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT TUNS EFFICIENCY[%] ACIN 100V ACIN 200V ACIN 100V ACIN 200V TUNS700F28-P 700.0 28V 25A 87typ 90typ 48 14.6 96max 96max 250max 300max 300max 450max 480max 960max 180max 38.40 - 52.80 (-Y1 Option : 38.4 - 57.6) 47.24 - 48.76 55.20 - 64.80 (-Y1 Option : 60.0 - 67.2) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 200V FREQUENCY[Hz] INPUT EFFICIENCY[%] ACIN 100V ACIN 200V ACIN 100V ACIN 200V POWER FACTOR (Io=100%) INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] VOLTAGE ACCURACY[%] 0 to +100C *1 OUTPUT RIPPLE[mVp-p] -40 to 0C *1 0 to +30% Load *1 0 to +100C *1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to +30% Load *1 PROTECTION OVERCURRENT PROTECTION CIRCUIT AND OVERVOLTAGE PROTECTION[V] REMOTE ON/OFF OTHERS TUNS-10 TUNS700F12-P TUNS700F28-P AC85 - 264 1f 8.6typ (Io=100%) 4.1typ (Io=100%) 50/60 (47 - 63) 83typ 86typ 86typ 89typ 0.96typ 0.93typ Limited by external resistance 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) 12 28 58.4 25 +5, -3 +5, -3 240max 360max 300max 400max 360max 540max 300max 400max 400max 600max 450max 600max Works over 105% of rating and recovers automatically 15.00 - 16.80 35.00 - 39.20 Optional (External power supply is required) TUNS700F48-P 87typ 90typ 48 14.6 +5, -3 600max 700max 900max 700max 1000max 1000max 55.20 - 64.80 TUNS700F GENERAL SPECIFICATIONS *4 INPUT-OUTPUT-RC INPUT-FG ISOLATION *4 OUTPUT-RC-FG *4 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE REGULATIONS HARMONIC ATTENUATOR CASE SIZE/WEIGHT OTHERS COOLING METHOD AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (2015C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (2015C) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (2015C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1 Complies with IEC61000-3-2 (Class A) *3 117.3X12.7X61.5mm [4.62X0.5X2.42 inches] (WXHXD) / 190g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) *1Refer to instruction manual for measuring method of electric characteristics. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Please contact us about another class. *4 "RC" is applicable when remote control (optional) is added. Lot No. Recommending size for processing PCB (TOP VIEW) [0.5] Base Plate (Aluminum) 12.7 0.5 External view 11- 1.5 15 15 [0.59] [0.59] 44.05 [1.73] 4- 3.5 10.2 10 9 3x4=12 [0.4] [0.39] [0.35] [0.47] 50.8 [2.0] 5.0 117.3 max [0.2] 0.5 Case (PBT) [4.62] 106.7 0.5 [4.2] (5.3) 2- 2 0.2 10 10.2 [0.47] [0.35] [0.39] [0.4] 3x4=12 9 [2.42] 0.5 [2.0] 50.8 61.5 max 10 10.2 [0.39] [0.4] [0.21] 2- 2.5 106.7 [4.2] 4 [0.16] 11- 1 0.1 15 15 44.05 [0.59] [0.59] [1.73] Control pin for Remote ON/OFF (Option) [0.16] [0.21] 4 Name Plate (5.35) Dimensions in : 4-M3 Mounting Hole AC1 -VOUT AC2 +VOUT -S, -M (Option : P) +S, +M (Option : P) TRM, NC (Option : P) IOG R +BC -BC RC2 (Option : R1/R2) RC1 (Option : R1/R2) Div. : 0.5inch mm [inch] Tolerance : 0.3 [ 0.012] Weight : 190g max Dimensions in mm, [ ]=inches Mounting hole screwing torque : 0.49N m (5.0kgf cm) max 4-FG TUNS-11 TUNS Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cosel: TUNS100F05 TUNS50F05 TUNS100F24 TUNS50F24 TUNS50F12 TUNS100F12 TUNS500F12 TUNS300F48 TUNS500F48 TUNS500F28 TUNS300F12 TUNS300F28 TUNS700F12 TUNS700F48 TUNS700F28