TUNS-2
TUNS50F
AC-DC Power Supplies Bus Converter.Power Module Type
TUN S 50 F 05 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
R
1 2 3 4 5 6
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*Keep TRM open, if output voltage adjustment is not necessary.
MODEL TUNS50F05 TUNS50F12 TUNS50F24
MAX OUTPUT WATTAGE[W] 50.0 50.4 50.4
DC OUTPUT 5V 10A 12V 4.2A 24V 2.1A
SPECIFICATIONS
MODEL TUNS50F05 TUNS50F12 TUNS50F24
INPUT
VOLTAGE[V] AC85 - 264 1f (Please refer to the instruction manual, 6.5 Derating)
CURRENT[A]
ACIN 100V
0.67typ (Io=100%)
ACIN 200V
0.35typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
79typ 83typ 84typ
ACIN 200V
81typ 84typ 86typ
POWER FACTOR (Io=100%)
ACIN 100V
0.95typ
ACIN 200V
0.90typ
INRUSH CURRENT Limited by external components (Thermistor)
LEAKAGE CURRENT[mA] 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1)
OUTPUT
VOLTAGE[V] 5 12 24
CURRENT[A] 10 4.2 2.1
LINE REGULATION[mV] 10max 24max 48max
LOAD REGULATION[mV] 10max 24max 48max
RIPPLE[mVp-p]
0 to +100C
*1
80max 120max 120max
-40 to 0C
*1
120max 150max 150max
0 to 15% Load
*1
200max 280max 380max
RIPPLE NOISE[mVp-p]
0 to +100C
*1
120max 150max 150max
-40 to 0C
*1
200max 200max 250max
0 to 15% Load
*1
280max 360max 460max
TEMPERATURE REGULATION[mV]
0 to +65C
50max 120max 240max
-40 to +100C
100max 240max 480max
DRIFT[mV]
*
2
20max 40max 90max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed (TRM pin open), adjustable by external resistor or external signal
4.50 - 6.00 10.80 - 13.20 21.60 - 26.40
OUTPUT VOLTAGE SETTING[V]
4.97 - 5.13 11.91 - 12.29 23.62 - 24.38
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
6.30 - 7.00 13.90 - 16.35 27.60 - 32.40
REMOTE SENSING Not provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AND
NOISE REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A)
*
3
OTHERS CASE SIZE/WEIGHT 58.4X12.7X37.3mm
[
2.3X0.5X1.47 inches
]
(WXHXD) / 80g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Please contact us about another class.
* Providing heat sink
as option
TUNS
TUNS-3
TUNS50F
External view
2- 2.5
5- 1.5
[1.9]
2- 3.5
[0.5]
[0.3]
[0.3]
[0.3] [1.0]
+VOUT
+BC -BC
TRM
-VOUT
AC2
AC1
±
0.1
5- 1
Name Plate
±
0.2
2- 2
Mounting Hole
2-M3
Case (PBT)
Lot No.
Base Plate (Aluminum)
48.3
12.7
7.62 25.4
58.4 max
1.27
37.3 max
48.3
±
0.5
7.62 7.62
5.0
±
0.5
±
0.5
(5.0)
12.7
27.9
±
0.5
(4.7)
7.627.62
12.7
7.62 25.4
1.27
[0.05]
[0.05]
[0.2] [1.9]
[2.3]
[0.3][1.0]
[1.1][0.19]
[1.47]
[0.3]
[0.3]
[0.5]
[0.5]
[0.2]
Div. : 0.2inch
Dimensions in : [inch]
mm
(TOP VIEW)
Recommending size for processing PCB
Tolerance : 0.3 [ 0.012]
Weight : 80g max
Dimensions in mm, [ ]=inches
Mounting hole screwing torque : 0.49N m (5.0kgf cm) max
TUNS
TUNS-4
TUNS100F
AC-DC Power Supplies Bus Converter.Power Module Type
TUN S 100 F 05 -O
Ordering information
R
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*Keep TRM open, if output voltage adjustment is not necessary.
*If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S.
MODEL TUNS100F05 TUNS100F12 TUNS100F24
MAX OUTPUT WATTAGE[W] 100.0 100.8 100.8
DC OUTPUT 5V 20A 12V 8.4A 24V 4.2A
SPECIFICATIONS
MODEL TUNS100F05 TUNS100F12 TUNS100F24
INPUT
VOLTAGE[V] AC85 - 264 1f (Please refer to the instruction manual, 6.5 Derating)
CURRENT[A]
ACIN 100V
1.3typ (Io=100%)
ACIN 200V
0.7typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
82typ 83typ 84typ
ACIN 200V
85typ 85typ 86typ
POWER FACTOR (Io=100%)
ACIN 100V
0.95typ
ACIN 200V
0.90typ
INRUSH CURRENT Limited by external components (Thermistor)
LEAKAGE CURRENT[mA] 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1)
OUTPUT
VOLTAGE[V] 5 12 24
CURRENT[A] 20 8.4 4.2
LINE REGULATION[mV] 10max 24max 48max
LOAD REGULATION[mV] 10max 24max 48max
RIPPLE[mVp-p]
0 to +100C
*1
80max 120max 120max
-40 to 0C
*1
120max 150max 150max
0 to 15% Load
*1
160max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +100C
*1
120max 150max 150max
-40 to 0C
*1
200max 200max 250max
0 to 15% Load
*1
240max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +65C
50max 120max 240max
-40 to +100C
100max 240max 480max
DRIFT[mV]
*
2
20max 40max 90max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed (TRM pin open), adjustable by external resistor or external signal
4.50 - 6.00 10.80 - 13.20 21.60 - 26.40
OUTPUT VOLTAGE SETTING[V]
4.97 - 5.13 11.91 - 12.29 23.62 - 24.38
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
6.30 - 7.00 13.90 - 16.35 27.60 - 32.40
REMOTE SENSING Provided
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AND
NOISE REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A)
*
3
OTHERS CASE SIZE/WEIGHT 58.4X12.7X61.0mm
[
2.3X0.5X2.4 inches
]
(WXHXD) / 120g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Please contact us about another class.
* Providing heat sink
as option
TUNS
TUNS-5
TUNS100F
External view
(TOP VIEW)
Recommending size for processing PCB
Tolerance : 0.3 [ 0.012]
Weight : 120g max
Dimensions in mm, [ ]=inches
Mounting hole screwing torque : 0.49N m (5.0kgf cm) max
[0.2] [1.9]
[2.3]
[0.3][1.0]
[0.2] [2.0]
[2.4]
[0.5]
[0.5]
[0.2]
[2.0]
[0.3] [0.4]
2- 2.5
7- 1.5
[0.2] [0.2]
[0.3] [0.3]
[0.3] [0.4][0.4] [0.3]
[1.9]
4- 3.5
[1.0]
[0.3]
-BC+BC
Name Plate
Mounting Hole
Case (PBT)
Lot No.
Base Plate (Aluminum)
±
0.1
7- 1
±
0.2
2- 2
4-M3
+VOUT
+S
TRM
-S
AC1
-VOUT
AC2
10.16
48.3
50.8
25.47.62
12.7
±
0.5
5.0
±
0.5
58.4 max
61max
7.62 25.4
7.62 7.627.62
5.08
5.08
50.8
±
0.5
5.1()
(5.0) 48.3
±
0.5
10.1610.16 7.62 7.62
12.7
Div. : 0.2inch
Dimensions in : [inch]
mm
TUNS
TUNS-6
TUNS300F
AC-DC Power Supplies Bus Converter.Power Module Type
TUN S 300 F 48 -O
Ordering information
R
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
Y1:
Outputvoltage adjustment
range ±20% (Only 48V)
R1: with Remote ON/OFF
R2: with Remote ON/OFF
(Low standby power)
*Avoid short circuit between +BC/R and -BC. It may cause the failure of inside components.
*Keep TRM open, if output voltage adjustment is not necessary.
*If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S.
MODEL TUNS300F12 TUNS300F28 TUNS300F48
MAX OUTPUT WATTAGE[W] 300 308 312
DC OUTPUT 12V 25A 28V 11A 48V 6.5A
SPECIFICATIONS
MODEL TUNS300F12 TUNS300F28 TUNS300F48
INPUT
VOLTAGE[V] AC85 - 264 1f
CURRENT[A]
ACIN 100V
3.6typ (Io=100%)
ACIN 200V
1.8typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
84typ 87typ 87typ
ACIN 200V
86typ 89typ 90typ
POWER FACTOR (Io=100%)
ACIN 100V
0.96typ
ACIN 200V
0.93typ
INRUSH CURRENT Limited by external resistance
LEAKAGE CURRENT[mA] 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1)
OUTPUT
VOLTAGE[V] 12 28 48
CURRENT[A] 25 11 6.5
LINE REGULATION[mV] 24max 56max 96max
LOAD REGULATION[mV] 24max 56max 96max
RIPPLE[mVp-p]
0 to +100C
*1
120max 180max 250max
-40 to 0C
*1
150max 200max 300max
RIPPLE NOISE[mVp-p]
0 to +100C
*1
150max 200max 300max
-40 to 0C
*1
200max 300max 450max
TEMPERATURE REGULATION[mV]
0 to +65C
120max 280max 480max
-40 to +100C
240max 560max 960max
DRIFT[mV]
*
2
40max 90max 180max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed (TRM pin open), adjustable by external resistor or external signal
9.60 - 14.40 22.40 - 33.60 38.40 - 52.80
(-Y1 Option : 38.4 - 57.6)
OUTPUT VOLTAGE SETTING[V]
11.91 - 12.29 27.56 - 28.44 47.24 - 48.76
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
15.00 - 16.80 35.00 - 39.20 55.20 - 64.80
(-Y1 Option : 60.0 - 67.2)
REMOTE SENSING Provided
REMOTE ON/OFF Optional (External power supply is required)
ISOLATION
INPUT-OUTPUT-RC
*
4
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-RC-FG
*
4
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OUTPUT-RC
*
4
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AND
NOISE REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A)
*
3
OTHERS CASE SIZE/WEIGHT 117.3X12.7X61.5mm
[4.62
X0.5X2.42 inches
]
(WXHXD) / 190g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Please contact us about another class.
*4 ”RC” is applicable when remote control (optional) is added.
TUNS
TUNS-7
TUNS300F
External view
(TOP VIEW)
Recommending size for processing PCB
Tolerance : 0.3 [ 0.012]
Weight : 190g max
Dimensions in mm, [ ]=inches
Mounting hole screwing torque : 0.49N m (5.0kgf cm) max
11- 1.5
2- 2.5
4- 3.5
[0.59] [0.59] [1.73]
[4.2]
[2.0]
[0.4] [0.39]
[0.35]
[0.47]
Name Plate
±
0.2
2- 2
4-M3
Case (PBT)
Lot No.
Base Plate (Aluminum)
11- 1
±
0.1
Mounting Hole
Control pin for Remote
ON/OFF (Option)
50.8
15
10 9
10.2
50.8
±
0.5
9
44.05
15
10
106.7
44.05
3×4=12
[0.47]
3×4=12
15
106.7
±
0.5
(5.3)
10
(5.35)
max117.3
max61.5
5.0
±
0.5
12.7
±
0.5
15
[4.2]
[4.62]
[0.21]
[0.59] [0.59] [1.73]
[0.5]
[0.2]
[2.0]
[0.21]
[2.42]
[0.39]
10.2
[0.4]
[0.39][0.35]
Div. : 0.5inch
Dimensions in : [inch]
mm
10.2
[0.4]
-VOUT
+VOUT
AC2
AC1
-S
+S
TRM
IO
RC2 (Option)
RC1 (Option)
G
R-BC+BC 4-FG
[0.16]
4
[0.16]
4
TUNS
TUNS-8
TUNS500F
AC-DC Power Supplies Bus Converter.Power Module Type
TUN S 500 F 48 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
Y1:
Outputvoltage adjustment
range ±20% (Only 48V)
R1: with Remote ON/OFF
R2: with Remote ON/OFF
(Low standby power)
R
1 2 3 4 5 6
*Avoid short circuit between +BC/R and -BC. It may cause the failure of inside components.
*Keep TRM open, if output voltage adjustment is not necessary.
*If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S.
MODEL TUNS500F12 TUNS500F28 TUNS500F48
MAX OUTPUT WATTAGE[W] 504 504 504
DC OUTPUT 12V 42A (Peak 55A) 28V 18A (Peak 24A) 48V 10.5A (Peak 14A)
SPECIFICATIONS
MODEL TUNS500F12 TUNS500F28 TUNS500F48
INPUT
VOLTAGE[V] AC85 - 264 1f
CURRENT[A]
ACIN 100V
6.0typ (Io=100%)
ACIN 200V
3.0typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
84typ 87typ 88typ
ACIN 200V
86typ 90typ 90.5typ
POWER FACTOR (Io=100%)
ACIN 100V
0.96typ
ACIN 200V
0.93typ
INRUSH CURRENT Limited by external resistance
LEAKAGE CURRENT[mA] 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1)
OUTPUT
VOLTAGE[V] 12 28 48
CURRENT[A]
*
3
42 (Peak 55) 18 (Peak 24) 10.5 (Peak 14)
LINE REGULATION[mV] 24max 56max 96max
LOAD REGULATION[mV] 24max 56max 96max
RIPPLE[mVp-p]
0 to +100C
*1
120max 180max 250max
-40 to 0C
*1
150max 200max 300max
RIPPLE NOISE[mVp-p]
0 to +100C
*1
150max 200max 300max
-40 to 0C
*1
200max 300max 450max
TEMPERATURE REGULATION[mV]
0 to +65C
120max 280max 480max
-40 to +100C
240max 560max 960max
DRIFT[mV]
*
2
40max 90max 180max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed (TRM pin open), adjustable by external resistor or external signal
9.60 - 14.40 22.40 - 33.60 38.40 - 52.80
(-Y1 Option : 38.4 - 57.6)
OUTPUT VOLTAGE SETTING[V]
11.91 - 12.29 27.56 - 28.44 47.24 - 48.76
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
15.00 - 16.80 35.00 - 39.20 55.20 - 64.80
(-Y1 Option : 60.0 - 67.2)
REMOTE SENSING Provided
REMOTE ON/OFF Optional (External power supply is required)
ISOLATION
INPUT-OUTPUT-RC
*
5
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-RC-FG
*
5
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OUTPUT-RC
*
5
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AND
NOISE REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A)
*
4
OTHERS CASE SIZE/WEIGHT 117.3X12.7X61.5mm
[4.62
X0.5X2.42 inches
]
(WXHXD) / 190g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 ( ) means peak current. Avoid operating with peak current continuously. It may cause failure of the components inside the product.
There are limitation of available condition of the peak current, such as peak time, duty etc. (Refer to the instruction manual in detail.)
*4 Please contact us about another class.
*5 ”RC” is applicable when remote control (optional) is added.
TUNS
TUNS-9
TUNS500F
External view
(TOP VIEW)
Recommending size for processing PCB
Tolerance : 0.3 [ 0.012]
Weight : 190g max
Dimensions in mm, [ ]=inches
Mounting hole screwing torque : 0.49N m (5.0kgf cm) max
11- 1.5
2- 2.5
4- 3.5
[0.59] [0.59] [1.73]
[4.2]
[2.0]
[0.4] [0.39]
[0.35]
[0.47]
Name Plate
±
0.2
2- 2
4-M3
Case (PBT)
Lot No.
Base Plate (Aluminum)
11- 1
±
0.1
Mounting Hole
Control pin for Remote
ON/OFF (Option)
50.8
15
10 9
10.2
50.8
±
0.5
9
44.05
15
10
106.7
44.05
3×4=12
[0.47]
3×4=12
15
106.7
±
0.5
(5.3)
10
(5.35)
max117.3
max61.5
5.0
±
0.5
12.7
±
0.5
15
[4.2]
[4.62]
[0.21]
[0.59] [0.59] [1.73]
[0.5]
[0.2]
[2.0]
[0.21]
[2.42]
[0.39]
10.2
[0.4]
[0.39][0.35]
Div. : 0.5inch
Dimensions in : [inch]
mm
10.2
[0.4]
-VOUT
+VOUT
AC2
AC1
-S
+S
TRM
IO
RC2 (Option)
RC1 (Option)
G
R-BC+BC 4-FG
[0.16]
4
[0.16]
4
TUNS
TUNS-10
TUNS700F
AC-DC Power Supplies Bus Converter.Power Module Type
TUN S 700 F 48 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 Universal Input
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
Y1:
Outputvoltage adjustment
range ±20% (Only 48V)
R1: with Remote ON/OFF
R2: with Remote ON/OFF
(Low standby power)
P : Parallel operation
(Output voltage variable,
Remote sensing disabled)
R
1 2 3 4 5 6
*Avoid short circuit between +BC/R and -BC. It may cause the failure of inside components.
*Keep TRM open, if output voltage adjustment is not necessary.
*If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S.
MODEL TUNS700F12 TUNS700F28 TUNS700F48
MAX OUTPUT WATTAGE[W] 700.8 700.0 700.8
DC OUTPUT 12V 58.4A 28V 25A 48V 14.6A
SPECIFICATIONS
MODEL TUNS700F12 TUNS700F28 TUNS700F48
INPUT
VOLTAGE[V] AC85 - 264 1f
CURRENT[A]
ACIN 100V
8.6typ (Io=100%)
ACIN 200V
4.1typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
83typ 86typ 87typ
ACIN 200V
86typ 89typ 90typ
POWER FACTOR
(Io=100%)
ACIN 100V
0.96typ
ACIN 200V
0.93typ
INRUSH CURRENT Limited by external resistance
LEAKAGE CURRENT[mA] 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1)
OUTPUT
VOLTAGE[V] 12 28 48
CURRENT[A] 58.4 25 14.6
LINE REGULATION[mV] 24max 56max 96max
LOAD REGULATION[mV] 24max 56max 96max
RIPPLE[mVp-p]
0 to +100C
*1
120max 180max 250max
-40 to 0C
*1
150max 200max 300max
RIPPLE NOISE[mVp-p]
0 to +100C
*1
150max 200max 300max
-40 to 0C
*1
200max 300max 450max
TEMPERATURE REGULATION[mV]
0 to +65C
120max 280max 480max
-40 to +100C
240max 560max 960max
DRIFT[mV]
*
2
40max 90max 180max
OUTPUT VOLTAGE ADJUSTMENT
RANGE[V]
Fixed (TRM pin open), adjustable by external resistor or external signal
9.60 - 14.40 22.40 - 33.60 38.40 - 52.80
(-Y1 Option : 38.4 - 57.6)
OUTPUT VOLTAGE SETTING[V]
11.91 - 12.29 27.56 - 28.44 47.24 - 48.76
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
15.00 - 16.80 35.00 - 39.20 55.20 - 64.80
(-Y1 Option : 60.0 - 67.2)
REMOTE SENSING Provided
REMOTE ON/OFF Optional (External power supply is required)
MODEL TUNS700F12-P TUNS700F28-P TUNS700F48-P
MAX OUTPUT WATTAGE[W] 700.8 700.0 700.8
DC OUTPUT 12V 58.4A 28V 25A 48V 14.6A
SPECIFICATIONS
MODEL TUNS700F12-P TUNS700F28-P TUNS700F48-P
INPUT
VOLTAGE[V] AC85 - 264 1f
CURRENT[A]
ACIN 100V
8.6typ (Io=100%)
ACIN 200V
4.1typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
83typ 86typ 87typ
ACIN 200V
86typ 89typ 90typ
POWER FACTOR
(Io=100%)
ACIN 100V
0.96typ
ACIN 200V
0.93typ
INRUSH CURRENT Limited by external resistance
LEAKAGE CURRENT[mA] 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1)
OUTPUT
VOLTAGE[V] 12 28 48
CURRENT[A] 58.4 25 14.6
VOLTAGE ACCURACY[%] +5, -3 +5, -3 +5, -3
RIPPLE[mVp-p]
0 to +100C
*1
240max 360max 600max
-40 to 0C
*1
300max 400max 700max
0 to +30% Load
*1
360max 540max 900max
RIPPLE NOISE[mVp-p]
0 to +100C
*1
300max 400max 700max
-40 to 0C
*1
400max 600max 1000max
0 to +30% Load
*1
450max 600max 1000max
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
15.00 - 16.80 35.00 - 39.20 55.20 - 64.80
REMOTE ON/OFF Optional (External power supply is required)
TUNS
TUNS-11
TUNS700F
External view
GENERAL SPECIFICATIONS
ISOLATION
INPUT-OUTPUT-RC
*
4
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-RC-FG
*
4
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
OUTPUT-RC
*
4
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AND
NOISE REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A)
*
3
OTHERS CASE SIZE/WEIGHT 117.3X12.7X61.5mm
[4.62
X0.5X2.42 inches
]
(WXHXD) / 190g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Please contact us about another class.
*4 ”RC” is applicable when remote control (optional) is added.
(TOP VIEW)
Recommending size for processing PCB
Tolerance : 0.3 [ 0.012]
Weight : 190g max
Dimensions in mm, [ ]=inches
Mounting hole screwing torque : 0.49N m (5.0kgf cm) max
11- 1.5
2- 2.5
4- 3.5
[0.59] [0.59] [1.73]
[4.2]
[2.0]
[0.4] [0.39]
[0.35]
[0.47]
Name Plate
±
0.2
2- 2
4-M3
Case (PBT)
Lot No.
Base Plate (Aluminum)
11- 1
±
0.1
Mounting Hole
Control pin for Remote
ON/OFF (Option)
50.8
15
10 9
10.2
50.8
±
0.5
9
44.05
15
10
106.7
44.05
3×4=12
[0.47]
3×4=12
15
106.7
±
0.5
(5.3)
10
(5.35)
max117.3
max61.5
5.0
±
0.5
12.7
±
0.5
15
[4.2]
[4.62]
[0.21]
[0.59] [0.59] [1.73]
[0.5]
[0.2]
[2.0]
[0.21]
[2.42]
[0.39]
10.2
[0.4]
[0.39][0.35]
Div. : 0.5inch
Dimensions in : [inch]
mm
10.2
[0.4]
-VOUT
+VOUT
AC2
AC1
-S, -M (Option : P)
+S, +M (Option : P)
TRM, NC (Option : P)
IO
RC2 (Option : R1/R2)
RC1 (Option : R1/R2)
G
R-BC+BC 4-FG
[0.16]
4
[0.16]
4
TUNS
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Cosel:
TUNS100F05 TUNS50F05 TUNS100F24 TUNS50F24 TUNS50F12 TUNS100F12 TUNS500F12 TUNS300F48
TUNS500F48 TUNS500F28 TUNS300F12 TUNS300F28 TUNS700F12 TUNS700F48 TUNS700F28