CT2578 / CT2581 SIMPLE REMOTE TERMINAL FOR MIL-STD-1553 / 1760 & McAir CIRCUIT TECHNOLOGY TECHNOLOGY CIRCUIT www.aeroflex.com/act1.htm www.aeroflex.com/act1.htm FEATURES Complete RT Protocol Meets MIL-STD-1553 A/B & MIL-STD-1760 Simple interface Dual Transceivers (1553 / 1760 or McAir) +5V only Power Supply Low Power (0.15 Watts per Channel) Only validated messages transferred Optional Data Wrap Around Store Released Signal Packaging - Hermetic Ceramic 119 Lead, 1.28" SQ. x .16" PGA 84 Lead, 1.645" SQ. x .14" CQFP Any Message may be Illegalized McAir Reduced Response Time Option (inh MC1F) Optional 1760 checksum 1760 Header word identification Latched RT Address MIL-PRF-38534 Compliant Circuits Available BUS 0 TRANSEIVER FUNCTIONAL BLOCK DIAGRAM MANCHESTER DECODER STATUS REGISTER 16 BIT RECEIVE BUFFER COMMAND REGISTER 16 BIT TRANSMIT BUFFER WORD COUNTER MANCHESTER DECODER LAST COMMAND REG WATCHDOG TIMER BIT REGISTER ENCODER / DECODER REMOTE TERMINAL STATE SEQUENCER MANCHESTER DECODER BUS 1 TRANSEIVER RT PROTOCOL 16 BIT RECEIVE BUFFER 16 BIT TRANSMIT BUFFER MANCHESTER DECODER CMD / HRD / DATA WATCHDOG TIMER ENCODER / DECODER STORE RELEASED HEADER WORD IDENT 1760 CHECKSUM GENERATION/VALIDATION 1760 OPTIONS 32 WORD DATA MEMORY eroflex Circuit Technology - Data Bus Modules For The Future (c) SCDCT2578 REV B 3/12/98 GENERAL DESCRIPTION SIGNAL DESCRIPTIONS CT2578 is for use in simple Remote Terminal applications without the need for a processor or software development. 1553 / 1760 DATA BUS DATABUS 0 Signal is connected to the positive side of the external data bus transformers for bus 0. It provides the complete protocol for a Remote Terminal, supporting all types of message transfers including all 15 mode codes, with comprehensive error checking. Error handling of data is not required by the subsystem. The user interface is a 16 bit bidirectional highway with a few control lines. NDATABUS 0 Signal is connected to the negative side of the external data bus transformers for bus 0. The low power transceivers are capable of providing the output voltage required by MIL-STD-1760 and are powered by a +5V supply. DATABUS 1 Signal is connected to the positive side of the external data bus transformers for bus 1. If sinusoidal (McAir) transceivers are required then the part number becomes CT2581. This is the only difference between CT2578 and CT2581. NDATABUS 1 Signal is connected to the negative side of the external data bus transformers for bus 1. A 32 word data buffer memory is used to store messages until validation is complete. Only validated messages are transferred to the subsystem at a rate of 500 nS per word. Data to be transmitted is transferred from the subsystem to this buffer memory at a maximum rate of 1 uS per word. This data memory may be bypassed in the receive mode and data transferred to the subsystem on a word by word basis as it is being received. HARD WIRED ADDR A-E (Inputs with pull up resistor) Remote Terminal address inputs for the unit. ADDR A is the least significant bit and ADDR E is the most significant bit. These inputs are internally latched every time the unit is reset. The latched address information is then compared to the incoming command word. The device has an optional RT wrap around capability. When WRAPEN is active, data received at subaddress 1E (30) remains stored in the data buffer memory (i.e. not transferred to the subsystem). If followed by a transmit from subaddress 1E the same data will be transmitted. ADDR P (Input with pull up resistor) Parity bit for the Remote Terminal address inputs. ADDR P must be set to ODD parity. This input is latched as above. There is an option within the device to reduce the response time in order to conform to other standards such as 1553A and McAir. In this mode subaddress 1F is allocated a normal subaddress with subaddress 00 reserved for mode commands. WRAPEN (Input with pull down resistor) Select Remote Terminal wrap around to subaddress 1E. The Bus Controller sends data to subaddress 1E which remains in the data buffer memory and is available to be sent back on the very next command by the Bus Controller. The data in the data buffer memory in this mode does not get transferred to the subsystem. If the very next command is not a transmit command to subaddress 1E, the data buffer memory is flushed and will respond normally to the next set of commands. If the wrap around test is enabled, data to subaddress 1E must be transferred in the correct sequence. "0" = Normal mode "1" = Wrap Around mode Any message may be illegalized by applying an active low on the NME discrete status input. The Remote Terminal will respond with the Message Error bit set in the status and not use the information received. A hardware implementation of the 1760 checksum algorithm within the device may be enabled via signal NENCHK. When transmitting, the checksum word is inserted in the last word position, and when receiving, a valid checksum word will generate the open drain output (STATUS). The STATUS output may be hard wired to any of the discrete status inputs (e.g. Service Request), if it is also hard wired to the input NILLCMD the device will respond to a failed checksum with the selected status bit set and not use the data (i.e. not transfer the data to the subsystem). MCAIR (Input with pull down resistor) This signal sets the unit to respond with a status word within 4 uS (dead bus time). Subaddress 1F is also enabled to be a valid subaddress for data. Normally subaddress 00 and 1F are reserved for mode codes. "1" = 4 uS dead bus response time, subaddress 1F used for data. "0" = 12 uS response time, subaddress 1F used for mode codes. In addition to the signal NVCR (valid command word received) which may be used to illegalize commands, a signal NHDR (header word received) is available to the subsystem for verification of the 1760 message header. C16MHZ (Input with pull up resistor) Free running 16 MHZ clock input. SUBSYSTEM INTERFACE The RT address lines are latched on RESET as required by 1760. If all six RT address lines go open circuit the store released signal (STREL) will go high. T0-T15 (Bibirectional IO) 16 bit bidirectional highway to transfer all information to / from subsystem. The user can also utilise this bus to monitor Command word and Header word (1760 requirement) for message illegalization. The device is packaged in a 119 pin grid array or 84 lead CQFP package. SCDCT2578 REV B 3/11/98 2 NRES (Bibirectional IO with pull up resistor) Bidirectional reset pin. Interface to this pin should be in the form of an open collector pull down driver. The unit will be reset when a low level input is asserted on power up. The pin is bidirectional in that the unit will drive the signal out low after the status response of the mode code Reset Remote Terminal. Upon reset the unit will be able to respond immediately after the rising edge of NRES. DISCRETE RT STATUS INPUTS The following signals are inputs to set the appropriate bits in the Remote Terminals status word. All inputs are sampled after NVCR except non mode code receive commands in which case they are sampled after the last data word has been received. All status inputs are active low. NME (Input with pull up resistor) Message Error, illegalizes message. No transfers to / from the subsystem will take place. No data will be transmitted following the status. NILLCMD (Input with pull up resistor) Input to illegalize a command to the Remote Terminal with a clear status response. The signal is sampled after NVCR except non mode code receive commands in which case it is sampled after the last data word has been received. A low on this input will illegalize the message, no transfers to / from the subsystem will take place. The device will respond with a clear status unless a bit has been specifically set. No data will be transmitted following status. NBUSY (Input with pull up resistor) Subsystem Busy. No data will be transferred to / from the subsystem and no data will be transmitted following status for non mode code transfers. NTF (Input with pull up resistor) Terminal Flag. NVCR (Output) Early indication that the Remote Terminal has received a command and the command word is available on T0-T15. This can be used for message illegalization. NSR (Input with pull up resistor) Service Request. NSSFLAG (Input with pull up resistor) Subsystem Flag. NDATA (Output) Access to valid data word in real time. Data word available on T0-T15 during active low signal. 1760 SIGNALS NCMDSTRB (Output) This signal indicates that a completely validated message has been received for standard subaddress data activity. Mode commands with or without data will not generate this signal. The NCMDSTRB signal is 8.5 uS long and is an indication that a DMA burst will initiate at the end of NCMDSTRB to transfer words between the 32 word data memory and the subsystem. The Command word is available on T0-T15 during this period. NENCHK (Input with pull up resistor) Enables / disables the internal hardware checksum generation and validation. When enabled, the circuitry will check all incoming data for correct checksum and generate the correct checksum word for an outgoing data transfer. "0" = Enable checksum circuitry. "1" = Disable checksum circuitry. STATUS (Open drain output) Open drain output will toggle high or low on each incoming data word from the 1553 data bus provided NENCHK is enabled. When the last data word is received the STATUS line is sampled by the protocol circuitry to determine if the checksum for the message is valid. At the end of the message, if STATUS is low then the checksum is not valid. This STATUS signal can be wired to several different pins to customise the units response to a checksum failure. STATUS can be wired to signals such as NILLCMD and NSR which would cause the message to be illegalized and set Service Request bit in the Status. NDATAST (Output) Signal to transfer normal validated received data from the data buffer memory to the subsystem at a rate of 500 nS per word via the T0-T15 highway. NSSTRB (Input with pull up resistor) Signal to transfer normal data for transmission from the subsystem to the data buffer memory at a maximum rate of 1 uS per word via the T0-T15 highway. C1MHZ (Output) Free running 1 MHZ clock to subsystem. NSSTRB must be synchronised to this clock. NHDR (Output) In Mil-Std-1760, the first data word of a message is defined as a Header word. The NHDR signal indicates the presence of the Header word on the T0-T15 highway as it is received. The Header is also stored in the data buffer memory along with the complete message. NENVW (Output) Signal to transfer Vector word from subsystem to unit in response to `Transmit Vector Word' mode command via the T0-T15 highway. STREL (Output) When the store is released from the aircraft all the Remote Terminal address inputs go high causing signal STREL to go high. NSYNC (Output) Signal to subsystem indicating receipt of a synchronise mode commands If the mode code has an associated data word, it will be available on T0-T15 at this time. If there is no associated data word, T0-T15 will be zero. SCDCT2578 REV B 3/11/98 3 MESSAGE FORMATS BC TO RT TRANSFER DATA BUS COMMAND DATA DATA DATA STATUS NVCR NHDR NDATA NCMDSTRB NDATAST T0-T15 1 1. 2. 3. 4. 5. 6. 7. 2 3 4 5 6 7 Valid command word received, contents available on T0-T15 for illegalization purposes. First valid data word (1760 header word) received, contents available on T0-T15 and stored in 32 word data memory. Second valid data word received, contents available on T0-T15 and stored in 32 word data memory. Last valid data word received, contents available on T0-T15 and stored in 32 word data memory. Status bits must be valid within 250nS. Status register contents transferred to transmit buffer. NCMDSTRB indicates valid message received, command word available on T0-T15. Data words transferred from 32 word data memory to subsystem at 500 nS per word. RT TO BC TRANSFER DATA BUS COMMAND STATUS DATA DATA DATA NVCR NCMDSTRB NSSTRB T0-T15 1 2 3 4 1. 2. 3. 4. Valid command word received, contents available on T0-T15 for illegalization purposes. Status must be valid within 600 nS. Status register contents transferred to transmit buffer. NCMDSTRB indicates valid message received, command word available on T0-T15. Data words transferred from subsystem to 32 word data memory at 1 uS per word. RT TO RT TRANSFER (RECEIVING TERMINAL) DATA BUS STATUS REC CMD TRAN CMD DATA DATA STATUS NVCR NHDR NDATA NCMDSTRB NDATAST T0-T15 1 SCDCT2578 REV B 3/11/98 2 3 4 4 5 6 7 8 1. 2. 3. 4. 5. 6. 7. 8. Valid receive command word received, contents available on T0-T15 for illegalization purposes. Valid transmit command word received, contents available on T0-T15. Status response of transmitting terminal received. First valid data word (1760 header word) received, contents available on T0-T15 and stored in 32 word data memory. Last valid data word received, contents available on T0-T15 and stored in 32 word data memory. Status bits must be valid within 250nS. Status register contents transferred to transmit buffer. NCMDSTRB indicates valid message received, command word available on T0-T15. Data words transferred from 32 word data memory to subsystem at 500 nS per word. MODE CODES WITHOUT DATA DATA BUS COMMAND STATUS NVCR NRES/NSYNC When applicable T0-T15 1 2 3 1. Valid command word received, contents available on T0-T15 for illegalization purposes. Status must be valid within 600 nS. 2. Status register contents transferred to transmit buffer. 3. Synchronise mode command, T0-T15 = 0. MODE CODES WITH DATA RECEIVE DATA BUS COMMAND STATUS DATA NVCR NDATA NSYNC When applicable T0-T15 1 1. 2. 3. 4. 2 3 4 Valid command word received, contents available on T0-T15 for illegalization purposes. Status must be valid within 600 nS. Valid data word received, contents available on T0-T15. Synchronise data word stored in 32 word data memory. Status register contents transferred to transmit buffer after message validation. Synchronise data word(when applicable) transferred from 32 word data memory to main memory and available on T0-T15. MODE CODES WITH DATA TRANSMIT DATA BUS COMMAND STATUS DATA NVCR NENVW When applicable T0-T15 1 2 3 1. Valid command word received, contents available on T0-T15 for illegalization purposes. Status must be valid within 600 nS. 2. Status register contents transferred to transmit buffer after message validation. 3. Vector word (when applicable) transferred from subsystem to transmit buffer. SCDCT2578 REV B 3/11/98 5 BC TO RT TRANSFER BROADCAST DATA BUS COMMAND DATA DATA DATA NVCR NHDR NDATA NCMDSTRB NDATAST T0-T15 1 1. 2. 3. 4. 5. 6. 2 3 4 5 6 Valid command word received, contents available on T0-T15 for illegalization purposes. First valid data word (1760 header word) received, contents available on T0-T15 and stored in 32 word data memory. Second valid data word received, contents available on T0-T15 and stored in 32 word data memory. Last valid data word received, contents available on T0-T15 and stored in 32 word data memory. Status bits must be valid within 250nS. NCMDSTRB indicates valid message received, command word available on T0-T15. Data words transferred from 32 word data memory to subsystem at 500 nS per word. RT TO RT TRANSFER BROADCAST (RECEIVING TERMINAL) DATA BUS STATUS REC CMD TRAN CMD DATA DATA NVCR NHDR NDATA NCMDSTRB NDATAST T0-T15 1 1. 2. 3. 4. 5. 6. 7. 2 3 4 5 6 7 Valid receive command word received, contents available on T0-T15 for illegalization purposes. Valid transmit command word received, contents available on T0-T15. Status response of transmitting terminal received. First valid data word (1760 header word) received, contents available on T0-T15 and stored in 32 word data memory. Last valid data word received, contents available on T0-T15 and stored in 32 word data memory. Status bits must be valid within 250nS. NCMDSTRB indicates valid message received, command word available on T0-T15 and stored in the 32 word command memory. Data words transferred from 32 word data memory to subsystem at 500 nS per word. MODE CODES WITHOUT DATA BROADCAST DATA BUS COMMAND NVCR NRES/NSYNC When applicable T0-T15 1 2 1. Valid command word received, contents available on T0-T15 for illegalization purposes. Status must be valid within 600 nS. 2. Synchronise mode command, T0-T15 = 0. SCDCT2578 REV B 3/11/98 6 MODE CODES WITH DATA RECEIVE BROADCAST DATA BUS COMMAND DATA NVCR NDATA NSYNC When applicable T0-T15 1 2 3 1. Valid command word received, contents available on T0-T15 for illegalization purposes. Status must be valid within 600 nS. 2. Valid data word received, contents available on T0-T15. Synchronise data word stored in 32 word data memory. 3. Synchronise data word (when applicable) transferred from 32 word data memory to main memory and available on T0-T15. REMOTE TERMINAL DETAIL RESVD Reserved: set to zero COMMAND REGISTER BCST Broadcast Command Received: set internally. BUSY Subsystem Busy: set with a discrete pin. The five most significant bits of the command register contain the Remote Terminal Address. SSFL Subsystem Flag: set with a discrete pin. Bit 10 of the register is the Transmit / Receive bit. If it is set to '1' the device will perform the transmit sequence and it is set to '0' it will perform the receive sequence. DBCA Dynamic Bus Control Acceptance: set to zero. TF Terminal Flag: set with a discrete pin. Bits 5 to 9 contain the Subsystem Address but two of these addresses are reserved and one programable. 11111 (1F) or 00000 (00) indicate that the command is a mode code. The least significant five bits of the command register are used to decode the mode code and are not used as the word counter as a mode code may only have a maximum of one associated word. The status register is cleared and the external bits loaded on all commands except 'Transmit Status' and 'Transmit Last Command'. The external status bits (both discrete and programable) must be valid 600 nS from the rising edge of NVCR for transmit commands and mode codes, and 250 nS from the rising edge of NDATA for the last data word in a receive message. 111110 (1E) and WRAPEN sets the sequencer up to perform the wrap around function. If discrete status inputs are not used they may be left open circuit. The least significant five bits of the command register contain the number of data words to be transmitted or received. 11111 is 31 words and 00000 is 32 words. STATUS RESPONSE TIME STATUS REGISTER The response time (all commands) measured from the mid bit zero crossing of the last bit of the last word to the mid bit zero crossing of the status word sync is nominally 11.0 uS. This time period is used to monitor for more data words on the bus. If a valid sync field followed by four valid Manchester bi-phase bits are detected then this is considered to be another word on the bus. ME Message Error: set internally as a result of an error in the received message or set externally with a discrete pin to illegalize a message. The response time may be reduced to 6.0 uS (4.0 uS dead bus time) by setting the MCAIR input active high. INST Instrumentation: set to zero. Any command or mode command may be illegalized by setting the NME input active low. The remote terminal will respond with status with the Message Error bit set, provided the message was valid, and not use the information received. There will be no transfers to or from the subsystem. MESSAGE ILLEGALIZATION SR Service Request: set with a discrete pin. SCDCT2578 REV B 3/11/98 7 One way to implement this function is to place a latching PROM to the T0-T10 data bus. The PROM would only have to decode 11 bits (5 bits subaddress, 5 bit word count and 1 bit T/R) and have a one bit output to place a high / low level on the NME input pin. The upper five bits (T11-T15) are just the Remote Terminal address for the unit which is constant so no decode of these bits is necessary. The latching signal for the PROM would be the NVCR line. The NME signal will remain latched and stable until the next rising edge of NVCR. The device will only consider a command word valid if the following conditions are met:a) It contains the correct sync field. b) Correct Manchester bi-phase (16 bits plus parity). c) Correct parity (odd). d) Correct terminal address or broadcast address. e) Does not follow contiguously a valid word on the same bus. Reserved mode commands are automatically declared illegal by the device and need not be included in the PROM decode. a) It contains the correct sync field. b) Correct Manchester bi-phase (16 bits plus parity). c) Correct parity (odd). d) Follows contiguously a valid word on the same bus. The device will only consider a data word valid if the following conditions are met:- All other conditions which require the message error bit to be set are automatic. Upon receipt of a valid command word the signal NVCR becomes active low for 500 nS. (The command word is available on T0-T15 during this period for message illegalization). 1760 CHECKSUM The 1760 checksum logic is enabled by setting the input NENCHK active low. On all commands except 'Wrap Around Transmit' the 32 data word memory is cleared. For transmit messages the checksum word is generated and inserted in the last word position of the transmitted message. RT TO BC TRANSFER For received messages the last data word receive (the checksum word) is validated. If this word meets the required criteria the output STATUS remains low. This signal will toggle up and down for each data word received as it is calculating the checksum. The open drain output (STATUS) signal may be hard wired to any of the discrete status inputs to set the required bit of the status response in the current message. In addition it may be hard wired to the input NILLCMD which will prevent the message being written to memory (e.g. if it is required to set the Service Request bit and not use the data for a failed checksum - hard wire STATUS to NSR and NILLCMD). If a valid command is received to transmit up to 32 data words the device will initially respond with Status. The signal NCMDSTRB goes low for 8.5 uS synchronized to the 1 MHZ clock indicating that a completely validated message has been received. The transmit Command word appears on T0-T15 at this time. If the Busy bit of the Status is set the sequence will terminate after NCMDSTRB. 1760 HEADER WORD The end of the NCMDSTRB will initiate the DMA cycle to transfer the data words from the subsystem to the data buffer memory in a single burst. In 1760 applications the first data word received is designated the header word. An output NHDR is provided to indicate the presence of this word on the highway T0-T15 for verification purposes. A failed header word may be treated in the same way as a failed checksum. STORE RELEASED The subsystem enables the first data word onto T0-T15 and applies a NSSTRB to the device synchronized to the 1 MHZ clock, this data is stored in the data buffer memory. The subsystem must continue transferring the correct amount of words to the device in this manner at a rate of between 62.5 kHz and 1 MHZ. The signal STREL is provided in 1760 applications to indicate to the subsystem that the store is no longer connected to the aircraft. Data is transferred from the data buffer memory to the output buffer for transmission as required by the 1553 data bus. If the 1760 checksum is enabled, the checksum word will be automatically generated and transmitted as the last data word. For example, if a Command is received to transmit five data words the subsystem can load four or five data words. If the subsystem loads four data words the device will generate the last data word for transmission. If the subsystem loads five data words the device will ignore the last data word and transmit the internally generated checksum word instead. INITIALISATION OF THE DEVICE The device must be reset to a known state on power up. (The RT address will be latched on power up). It will remain inactive until a valid command word is received. If the device is in the process of sequencing a command and a new command is received on the alternative bus, the sequence will be terminated and the device will sequence the new command. SCDCT2578 REV B 3/11/98 8 Error Conditions The end of the NCMDSTRB will initiate the DMA cycle to transfer the data words from the data buffer memory to the subsystem. The first word received is enabled onto T0-T15 and the signal NDATAST is pulsed low. This sequence is repeated for each data word that was received. Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. Broadcast address. No status response. Set message error. Set broadcast. Sequence terminated. 4. Too few NSSTRB from subsystem. Message truncated. 5.Too many NSSTRB from subsystem. Bit 1 of BIT register set. Too many data words will not be transmitted. Error Conditions Note: Sequence terminated - termination will take place before signal NCMDSTRB becomes active, therefore no transfers to / from subsystem will occur. 1. Invalid command. No response. Command ignored. 2. Invalid data word. No status response. Set message error. Sequence terminated. 3. Non contiguous data. No status response. Set message error. Sequence terminated. 4. Too few data words. No status response. Set message error. Sequence terminated. 5. Too many data words. No status response. Set message error. Set broadcast. Sequence terminated. BC TO RT TRANSFER RX CMD DATA DATA DATA Note: Sequence terminated - termination will take place before signal NCMDSTRB becomes active, therefore no transfers to / from subsystem will occur. * STATUS If a valid command is received to receive up to 32 data words and the second word is another command word then an RT to RT transfer has been set up (see RT to RT transfer). RT TO RT TRANSFER All valid data words received are stored in the data buffer memory until message validation is complete after which the device will respond with Status. RX CMD TX CMD * STATUS DATA * STATUS To initiate an RT to RT transfer the Bus Controller will send a receive command to RTA followed contiguously by a transmit command to RTB. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Data words are also available on T0-T15 as they are received indicated by signal NDATA. RTB will respond with status and contiguous data (see RT to BC transfer). Only after the message has been completely validated will the data be transferred to the subsystem in a single burst at 500 nS per word. This ensures that only complete validated messages are transferred to the subsystem. RTA (the receiving terminal) will receive the status and data transmitted by RTB and store the received data in the data buffer memory until the entire RT to RT transfer has been validated, after which it will respond with its own status provided it was not a broadcast command, in which case the status transmission will be suppressed and the broadcast bit set. It will then transfer the data to the subsystem (see BC to RT transfer). When a complete validated message is stored in the data buffer memory the signal NCMDSTRB goes low for 8.5 uS synchronized to the 1 MHZ clock indicating that a completely validated message has been received. The receive Command word appears on T0-T15 at this time. The error detection for the transmitting terminal will be the same as for RT to BC transfer. The error detection for the receiving terminal is as follows:- If the Busy bit of the Status is set the sequence will terminate after NCMDSTRB. SCDCT2578 REV B 3/11/98 Action taken by device 9 Error Conditions Action taken by device Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 1. Invalid receive command. No response. Command ignored. 2. Non contiguous command words. No status response. Set message error. Sequence terminated. 2. Invalid data word. No status response. Set message error. Sequence terminated. 3. Non contiguous data. 3. Transmit command followed by another word (excluding command word for RTA, in which case it will respond to the latest command). No status response. Set message error. Sequence terminated. No status response. Set message error. Sequence terminated. 4. Too few or too many data words. No status response. Set message error. Sequence terminated 4. Transmitting terminal does not respond with status within 16 uS. No status response. Set message error. Sequence terminated. 5. Invalid transmit command. No response. Command ignored. 6. Transmit command followed by another word. No status response. Set message error. Sequence terminated 5. Incorrect terminal transmitting. No status response. Set message error. Sequence terminated. 7.Transmit Broadcast address. 6. Non contiguous data following status from RTB. No status response. Set message error. Sequence terminated No status response. Set message error. Set broadcast. Sequence terminated. 8. Transmit word count not equal to receive word count. No data transmission. Set message error. Sequence terminated. 7. Invalid data transmitted from RTB. No status response. Set message error. Sequence terminated. 8. Too few or too many data words. No status response. Set message error. Sequence terminated. DYNAMIC BUS CONTROL (00) DBC CMD * STATUS The device will respond with status. Error Conditions WRAP AROUND RX CMD DATA DATA TX CMD * STATUS DATA DATA DATA * STATUS SCDCT2578 REV B 3/11/98 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. Broadcast address. No status response. Set message error. Set broadcast. Sequence terminated. 5. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. DATA The wrap around capability is for test purposes only. It will test for transfers to and from the Bus Controller without any sub system intervention. The wrap around sequence will commence on receipt of a valid receive command word containing the wrap around subaddress (1E) providing the WRAPEN input is set high. The data received is stored in the data buffer memory and the device will respond with status. The Bus Controller will then send a transmit command to subaddress 1E and the data contained in the memory will be transmitted following the status. For the test to operate correctly the number of data words to be transmitted must be the same as the number received. 10 Action taken by device SYNCHRONIZE WITHOUT DATA WORD (01) SYNC CMD INITIATE SELF TEST (03) I.S.T CMD * STATUS The device will respond with status. The NSYNC signal will go active low for 500 nS. Throughout this period the highway T0T15 will be zero and remain at zero until the next command is received. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Error Conditions The device will respond with status.. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. * STATUS Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. TRANSMITTER SHUTDOWN (04) TRANSMIT STATUS (02) TX ST CMD * TX DIS CMD STATUS The device will respond with status and shutdown the transmitter on the alternate bus, thus inhibiting any further transmission on that bus. Once a transmitter has been shutdown it can only be reactivated by the mode commands 'Override Transmitter Shutdown' or 'Reset Remote Terminal'. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. The status register is not cleared or loaded before it is transmitted, i.e. it contains the resulting status from the previous command. Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. Broadcast address. 5. T/R bit of command set to zero and broadcast address * STATUS Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Set broadcast. Sequence terminated. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated No status response. Set message error. Set broadcast. Sequence terminated. 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. SCDCT2578 REV B 3/11/98 11 OVERRIDE TRANSMITTER SHUTDOWN (05) TX EN CMD OVERRIDE INHIBIT TERMINAL FLAG (07) EN TF CMD * STATUS The device will respond with status and reactivate a shutdown transmitter on the alternate bus. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Error Conditions * STATUS The device will respond with status and then reactivate the Terminal Flag bit of the status register. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Action taken by device Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. INHIBIT TERMINAL FLAG (06) INH TF CMD RESET REMOTE TERMINAL (08) RESET CMD * STATUS The device will respond with status and then inhibit any further setting of the Terminal Flag bit of the status. Once the Terminal Flag bit has been inhibited it can only be reactivated by the mode commands 'Override Inhibit Terminal Flag' or 'Reset Remote Terminal'. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Error Conditions * STATUS The device will respond with status after which the bidirectional signal NRES to the subsystem will go active low for 500 nS. Transmitter Shutdown mode commands and Inhibit Terminal Flag mode command will be reactivated. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Action taken by device Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. SCDCT2578 REV B 3/11/98 12 RESERVED MODE CODES (09-0F) RESVD CMD SYNCHRONIZE WITH DATA WORD (11) SYNC DATA CMD * STATUS The status is not cleared or loaded before it is transmitted with the message error bit set. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Error Conditions * STATUS The Synchronize data word received is stored in the data buffer memory until message validation is complete after which the device will respond with Status. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 1. Invalid command. No response. Command ignored. 4. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. 2. Command not followed contiguously by data word No status response. Set message error. Sequence terminated. 3. Command followed by too many words. No status response. Set message error. Sequence terminated 4. T/R bit of command set to one. No status response. Set message error. Sequence terminated. 5. T/R bit of command set to one and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. After the Status response has been initiated the Synchronize Word will be transferred to the subsystem. The NSYNC signal will go active low for 500 nS during which time T0-T15 will be set to the data word received. Error Conditions TRANSMIT VECTOR WORD (10) TX VW CMD * STATUS VW On receipt of a valid Command to transmit the Vector Word the device will initially respond with Status. After the Status response has been initiated the Vector Word will be enabled onto T0-T15 from the subsystem with signal NENVW and transferred to the Output Buffer ready for transmission onto the 1553 data bus following the Status. Error Conditions 1. Invalid command. Action taken by device Action taken by device No response. Command ignored. TRANSMIT LAST COMMAND (12) 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated The status response contains the resulting status from the previous command. 4. Broadcast address. No status response. Set message error. Set broadcast. Sequence terminated. The data word transmitted following the status word contains the previous valid command (provided it was not Transmit Last Command). 5. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. SCDCT2578 REV B 3/11/98 TX LST CMD 13 * STATUS LST CMD Error Conditions SELECTED TRANSMITTER SHUTDOWN (14) Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. Broadcast address. No status response. Set message error. Set broadcast. Sequence terminated. 5. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. TX DIS DATA CMD * STATUS This mode command is not normally used in dual redundant systems. The device will respond with status and shut down the transmitter on the bus designated by the two least significant bits of the data word. The bus addresses of the device are channel 0 - 00, channel 1 - 01. If the command is received on the same bus as the designated shut down bus then the device will respond with status and no shut down will occur. Once a transmitter has been shut down it can only be reactivated by an 'Override Shutdown Command' or 'Reset Remote Terminal'. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 2. Command not followed contiguously by data word No status response. Set message error. Sequence terminated. 3. Command followed by too many words. No status response. Set message error. Sequence terminated 4. T/R bit of command set to one. No status response. Set message error. Sequence terminated. 5. T/R bit of command set to one and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. TRANSMIT BIT WORD (13) TX BIT CMD * STATUS BIT WORD On receipt of a valid Command to transmit the BIT Word the device will respond with Status followed by the BIT word, after which the BIT register is cleared. Bits 2 to 15 are always zero. Bit 1 is set if the subsystem sends too many NSSTRB's. Error Conditions Action taken by device 1. Invalid command. No response. Command ignored. 2. Command followed by another word. No status response. Set message error. Sequence terminated. 3. T/R bit of command set to zero. No status response. Set message error. Sequence terminated 4. Broadcast address. No status response. Set message error. Set broadcast. Sequence terminated. 5. T/R bit of command set to zero and broadcast address No status response. Set message error. Set broadcast. Sequence terminated. SCDCT2578 REV B 3/11/98 OVERRIDE SEL TRANSMITTER SHUTDOWN (15) TX EN DATA CMD * STATUS This mode command is not normally used in dual redundant systems. The device will respond with status and reactivate a shutdown transmitter on the bus designated by the two least significant bits of the data word. The bus addresses of the device are channel 0 - 00 channel 1 - 01. If the command is received on the same bus as the designated override shutdown bus then the device will respond with status and no reactivation will occur. If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. 14 Error Conditions 1. Invalid command. 1 No response. Command ignored. 2. Command not followed contiguously by data word No status response. Set message error. Sequence terminated. 3. Command followed by too many words. No status response. Set message error. Sequence terminated 4. T/R bit of command set to one. No status response. Set message error. Sequence terminated. 5. T/R bit of command set to one and broadcast address DETAILED TIMING Action taken by device NVCR T0-T15 4 STATUS 6 8 STATUS No status response. Set message error. Set broadcast. Sequence terminated. MIN MAX UNIT 1. 2. 3. 4. 5. 6. 7. 8. * STATUS The status is not cleared or loaded before it is transmitted with the message error bit set. NVCR pulse duration 500 NVCR to T0-T15 valid 250 NVCR to T0-T15 invalid 250 NVCR to discrete status inputs (not rec) NDATA & NHDR pulse duration 475 T0-T15 valid to NDATA & NHDR 250 NDATA & NHDR to T0-T15 invalid 250 Last NDATA to discrete status inputs (rec) 1 650 nS 600 525 250 nS nS nS nS nS nS nS 1 C1MHZ If the command was a broadcast the status transmission will be suppressed and the broadcast bit in the status register set. Error Conditions 7 T0-T15 * STATUS RESVD DATA T/R=0 5 NDATA NHDR RESERVED MODE CODES (16-1F) RESVD T/R=1 3 2 2 NCMDSTRB 3 Action taken by device 4 T0-T15 T/R=1 1. Invalid command. 2. Command followed by another word. MIN No response. Command ignored. 1. 2. 3. 4. No status response. Set message error. Sequence terminated. C1MHZ to NCMDSTRB NCMDSTRB duration T0-T15 valid to NCMDSTRB NCMDSTRB to T0-T15 invalid 8475 100 100 MAX UNIT 75 8525 T/R=0 No response. Command ignored. C1MHZ 4. Command not followed contiguously by data word. No status response. Set message error. Sequence terminated. NCMDSTRB 5. Command followed by too many data words. No status response. Set message error. Sequence terminated. 3. Invalid command. SCDCT2578 REV B 3/11/98 2 1 3 NSSTRB 5 T0-T15 15 6 nS nS nS nS MIN MAX UNIT 1. Rising edge of NCMDSTRB to falling 0.5 10.0 edge of first NSSTRB 2. NSSTRB to next NSSTRB 1.0 16.0 3. Rising edge of C1MHZ to falling edge 75 of NSSTRB 4. Falling edge of C1MHZ to rising edge 75 of NSSTRB 5. Falling edge of NSSTRB to data enabled 75 onto T0-T15 from subsystem 6. Rising edge of NSSTRB to data disabled 75 onto T0-T15 from subsystem 16 MHZ CLOCK REQUIREMENT uS uS nS nS nS nS MIN 40% T MAX 60% of cycle C1MHZ 1 NCMDSTRB 2 TRANSFORMERS 3 NDATAST 4 The device requires a 1:2.5 turns ratio for direct coupling and 1:1.79 turns ratio for transformer coupling. The centre tap of the transformers must be tied to ground. 5 T0-T15 The suggested transformer are:Technitrol 1553-45 Aeroflex 25T1553-45 MIN MAX UNIT 1. Rising edge of NCMDSTRB to falling 225 275 edge of first NDATAST 2. NDATAST to next NDATAST 475 525 3. NDATAST pulse duration 225 275 4. Data valid on T0-T15 to NDATAST 100 5. NDATAST to data invalid on T0-T15 100 nS nS nS nS nS DATA 1 P 1:1.79 0.75Zo 1:1.4 NRES/NSYNC 2 3 NDATA T0-T15 0.75Zo P' Transformer coupled 5 NENVW DATA 6 1:2.5 T0-T15 1. 2. 3. 4. NRES/NSYNC pulse duration T0-T15 valid to NSYNC NSYNC to T0-T15 invalid NVCR to NRES/NSYNC non bcast NVCR to NRES/NSYNC bcast 5. NENVW to T0-T15 valid 6. NENVW to T0-T15 invalid 7. NENVW is reset by NVCR SCDCT2578 REV B 3/11/98 475 525 50 250 27.9 28.1 8.9 9.1 250 500 Direct coupled nS nS nS uS uS nS nS 16 A 0.75Zo NDATA MIN MAX UNIT 0.75Zo A' Zo MIN NOM MAX UNIT OPERATING CONDITIONS E. Not Used ABSOLUTE MAXIMUM RATINGS VDD Supply voltage VSS Supply voltage VIH High level input voltage VIL Low level input voltage Operating free air temperature range Storage temperature range +7 0 VDD+0.5 VSS-0.5 -55 to +125 -65 to +150 Volts Volts Volts Volts C C F. INPUT OUTPUT VIH VIL IIH IIL CIN VOH VOL IOH IOL IHZ RECOMMENDED OPERATING CONDITIONS MIN NOM MAX UNIT VDD Supply voltage Free air temperature range 4.75 5.0 -55 5.5 +125 Volts C High level input voltage Low level input voltage High level input current Low level input current Input capacitance High level output voltage Low level output voltage High level output current Low level output current High impedance IO current 2.4 VSS VDD-0.5 2.0 2.0 5.5 5.5 VDD 0.8 10 10 10 VDD 0.4 10.0 10.0 10 Volts Volts uA uA pf Volts Volts mA mA uA Volts Volts uA uA pf Volts Volts mA mA G. INPUT OUTPUT WITH PULL UP ELECTRICAL CHARACTERISTICS VIH VIL IIH IIL CIN VOH VOL IOH IOL DIGITAL SIGNALS MIN NOM MAX UNIT A1. INPUT WITH PULL UP VIH VIL IIH IIL CIN High level input voltage Low level input voltage High level input current Low level input current Input capacitance 2.4 VSS 35 65 oc 0.8 10 120 10 Volts Volts uA uA pf High level input voltage Low level input voltage High level input current Low level input current Input capacitance High level input voltage Low level input voltage High level input current Low level input current Input capacitance 2.4 VSS 450 800 oc 0.8 10 1500 10 IO VO Volts Volts uA uA pf TRF VOE 2.4 oc 35 65 VDD 0.8 120 10 10 Volts Volts uA uA pf VO High level output voltage Low level output voltage High level output current Low level output current High level output voltage Low level output voltage High level output current Low level output current SCDCT2578 REV B 3/11/98 7.0 7.5 600 9.0 mA V p-p 100 200 300 nS 90 mV 9.0 V p-p 800 VDD-0.5 VDD-0.5 2.0 2.0 5.5 5.5 VDD 0.4 10.0 10.0 Volts Volts mA mA 5.5 oc 0.4 10 10.0 Volts Volts uA mA 2.0 Driver peak output current Differential output level point A-A' (RL=35 ohms) on 1760 BUS Rise and fall times (10%-90% of p-p output) Output offset 2.5 uS after mid bit crossing of parity, point A-A' (RL=35 ohms) Differential output level point A-A' (RL=35 ohms) on 1553 BUS -90 6.0 7.5 VIDR Differential input level 14 20 point P-P' (TXFMR-2.12:1) CMRR Common mode rejection 45 ratio VTH Input threshold voltage 0.60 0.82 1.20 referred to the bus (100KHz-1MHz) D. OPEN DRAIN OUTPUT VOH VOL IOH IOL 1.0 5.0 450 H. RECEIVER C. OUTPUT VOH VOL IOH IOL 0.5 1.5 oc 0.8 10 1500 10 VDD 0.4 1.8 9.0 H. TRANSMITTER B. INPUT WITH PULL DOWN VIH VIL IIH IIL CIN oc VSS DATA BUS SIGNALS A2. INPUT WITH PULL UP VIH VIL IIH IIL CIN High level input voltage Low level input voltage High level input current Low level input current Input capacitance High level output voltage Low level output voltage High level output current Low level output current 17 V p-p dB V p-p PIN ASSIGNMENTS -PGA (2578/81-02-XX-YY-P119) PGA SIGNAL IO TYPE PGA SIGNAL IO TYPE G12 STREL (-12 only) C K3 ADDR E A1 F12 NSR A2 N1 ADDR D A1 ADDR C A1 E12 WRAPEN B M3 E11 T0 F L4 ADDR B A1 C12 T1 F N3 ADDR A A1 D11 T2 F N4 ADDR P A1 A13 T3 F N5 DATABUS 0 H NDATABUS 0 H B11 T4 F L6 C10 T5 F L7 VDD A11 T6 F M7 VSS A10 T7 F N9 C16MHZ A2 A9 DATABUS 1 H N10 NDATA C H M11 NRES G C8 NDATABUS 1 C7 VDD L10 NSSTRB A1 B7 VSS M12 C1MHZ C C6 NILLCMD A2 L11 NCMDSTRB C A4 T8 F K11 NDATAST C A3 T9 F K12 NENVW C C4 T 10 F J12 NSSFLAG A2 A2 T 11 F H11 NBUSY A2 B2 T 12 F G13 NHDR (-12 only) C D3 T 13 F M9 LA (-12 only) A1 C1 T 14 F G1 NVALCHK (-12 only) C N/C E3 T 15 F F2 E1 NSYNC C M5 N/C F1 MCAIR B N8 N/C G3 STATUS (-12 only) D H12 N/C H2 NENCHK (-12 only) A1 B9 N/C N/C J2 NVCR C A6 J3 NTF A2 A5 N/C L2 NME A2 B5 N/C B4 N/C B3 N/C SCDCT2578 REV B 3/11/98 18 PACKAGE OUTLINE 119 Pin PGA DIMENSIONS (Inches) SCDCT2578 REV B 3/11/98 REF MIN NOM MAX A 0.160 - 0.210 A1 0.040 0.050 0.060 b 0.016 0.018 0.020 D 1.280 - 1.335 E 1.280 - 1.335 e1 - 0.100 - e - 1.200 - L 0.110 0.130 0.150 19 PIN ASSIGNMENTS (2578/81-02-XX-YY-F84) CQFP SIGNAL IO TYPE 43 C1MHZ C F 44 NCMDSTRB C F 45 NDATAST C NENVW C SIGNAL IO TYPE 1 T12 F 2 T13 3 T14 CQFP 4 T15 F 46 5 NSYNC C 47 NSSFLAG A2 6 MCAIR B 48 NBUSY A2 7 NVALCHK (-12 only) C 49 N/C D 50 NHDR (-12 only) C 8 STATUS (-12 only) 9 N/C 51 N/C 10 N/C 52 STREL (-12 only) C 11 NENCHK (-12 only) A1 53 NSR A2 N/C 12 NVCR C 54 13 BCST C 55 N/C 14 NTF A2 56 WRAPEN N/C B 15 N/C 57 16 N/C 58 T0 17 NME A2 59 N/C 18 ADDRE A1 60 N/C T1 F F F 19 N/C 61 20 N/C 62 T2 21 ADDRD A1 63 N/C 22 ADDRC A1 64 N/C A1 65 N/C 66 T3 F 67 T4 F T5 F 23 ADDRB 24 N/C 25 ADDRA A1 26 N/C 68 27 N/C 69 N/C 28 ADDRP A1 70 T6 29 DATA H 71 N/C H 72 N/C 0 (BUS) F 30 NDATA 0 (BUS) 31 N/C 73 T7 F 32 N/C 74 DATA 1 (BUS) H 33 N/C 75 NDATA 1 (BUS) H 34 VDD 76 N/C 35 VSS 77 N/C 36 C16MHZ A2 78 VDD 37 LA (-12 only) A1 79 VSS C 80 NILLCMD A2 38 NDATA 39 N/C 81 T8 F 40 N/C 82 T9 F 41 NRES G 83 T10 F A1 84 T11 F 42 NSSTRB N/C = Do not connect SCDCT2578 REV B 3/11/98 20 CQFP - Flat Package Outline POWER SUPPLY REQUIREMENTS APPLICATION NOTES CURRENT MAX UNIT Transmitter standby (both channels) 60 mA 25% duty cycle (one channel) 220 mA 50% duty cycle (one channel) 350 mA POWER DISSIPATION MAX UNIT Transmitter standby (both channels) 0.3 watts 50% duty cycle (one channel) 0.6 watts 100% duty cycle (one channel) 0.9 watts CIRCUIT TO TRANSFER DATA FROM SUBSYSTEM POWER SUPPLY DECOUPLING To maximize stabilization of the devices transceivers, a 4.7 uf and a 0.1 uf capacitor should be connected in parallel from the +5V supply to ground. SCDCT2578 REV B 3/11/98 21 CIRCUIT TECHNOLOGY Ordering Information DESC Part Number Package CT2578-02-QM-P119 TBD 119 Pin PGA CT2578-02-XT-P119 TBD 119 Pin PGA CT2578-02-IN-P119 TBD 119 Pin PGA CT2578-02-CG-P119 TBD 119 Pin PGA Model Number * MIL-STD-1760 Pinout McAir Compliant CT2578-12-QM-P119 TBD 119 Pin PGA CT2578-12-XT-P119 TBD 119 Pin PGA CT2578-12-IN-P119 TBD 119 Pin PGA CT2578-12-CG-P119 TBD 119 Pin PGA CT2578-02-QM-F84 TBD 84 Lead CQFP CT2578-02-XT-F84 TBD 84 Lead CQFP CT2578-02-IN-F84 TBD 84 Lead CQFP CT2578-02-CG-F84 TBD 84 Lead CQFP CT2578-12-QM-F84 TBD 84 Lead CQFP CT2578-12-XT-F84 TBD 84 Lead CQFP CT2578-12-IN-F84 TBD 84 Lead CQFP CT2578-12-CG-F84 TBD 84 Lead CQFP CT2581-02-QM-P119 TBD 119 Pin PGA CT2581-02-XT-P119 TBD 119 Pin PGA CT2581-02-IN-P119 TBD 119 Pin PGA CT2581-02-CG-P119 TBD 119 Pin PGA CT2581-02-QM-F84 TBD 84 Lead CQFP CT2581-02-XT-F84 TBD 84 Lead CQFP CT2581-02-IN-F84 TBD 84 Lead CQFP CT2581-02-CG-F84 * Screening Code Breakdown TBD 84 Lead CQFP QM = MIL-STD-883 Compliant XT = Extended Temperature Range (-55C to +125C) IN = Industrial Temperature Range (-40C to +85C) CG = Commercial Temperature Range (-0C to +70C) Specifications subject to change without notice. Aeroflex Circuit Technology 35 South Service Road Plainview New York 11830 Aeroflex Circuit Technology Telephone: (516) 694-6700 FAX: (516) 694-6715 Toll Free Inquiries: 1-(800) 843-1553 22 SCDCT2578 REV B 3/12/98 Plainview NY (516) 694-6700