"SPECIFICATION CONTROL DRAWING __ CMC-0554 WIRE, ELECTRIC, RADIATION-CROSSLINKED, MODIFIED Onto | Revision ETFE-INSULATED, NICKEL-COATED COPPER 9-29-98 S This specification sheet forms a part of the latest issue of Raychem Specification 80. CONOUCTOR - NICKEL-COATED COPPER JACKET - RADIATION-CROSSLINKED, . MODIFIED, FLEXIBLE ETFE W & C DESIGN _ RED STAMP - CONTROL COPY BLACK STAMP - CHECK FOR LATEST ISSUE PRIMARY INSULATION - RADIATION-CROSSLINKED, .. . _ BRAID- NOMEX BRAID TREATED MODIFIED, FLEXIBLE ETFE TO PREVENT FRAYING COLOR - LIGHT GREEN TABLE |. CONSTRUCTION DETAILS DIAMETER OF Wine STRANDED MAXIMUM wire | CONDUCTOR PART NUMBER | URE | CORANDING CONDUCTOR RESISTANCE] DIAMETER | MAXIMUM (AWG) |(number x AWG) (in) AT 20C (in.) (Ib8/1000 ft.) 3 F< Pe foc] oc Foc oe 1 < TABLE II. PER MANDREL DIAMETER WEIGHT PART NUMBER (in.) (3%) .--CROSSLINKING PROOF : CROSSLINKING PROOF TEST TEST COLORS AND COLOR CODE DESIGNATORS SHALL SE IN ACCORDANCE WITH MIL-STD-681. a Raychem DIMENSIONS ARE iN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Page 1 of 2 DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 1-800-2 Raychem Fax: 1-650-361-6297 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED | nn Conettution Drive, Menlo Park, Caillomia 9402SCD Number Page 2 of 2 - CMC-0554 SPECIFICATION CONTROL DRAWING WIRE RATINGS AND ADDITIONAL REQUIREM iy & C DESIGN RED STAMP - CONTROL COPY BLACK STAMP - CHECK FOR TEMPERATURE RATING: 200C LATEST ISSUE Maximum continuous conductortemperature VOLTAGE RATING: 600 volts (rms) COLOR: White, or dark green with Munsell color limits SY 3/2 and 5B 2/0.5 CONCENTRICITY: 70% (minimum) + CROSSLINKING PROOF TEST: 300 + 3C for7 hours INSULATION ELONGATION AND TENSILE STRENGTH: (Both tayers- pulled individually or together) Elongation, 150% (minimum) Tensile Strength, 3000 lbf/in? (minimum) INSULATION FLAWS: Primary Insulation, Impulse Dielectric Test, 6.0 kV (peak) Finished Wire, impulse Dielectric Test, 8.0 kV (peak) INSULATION THICKNESS: ForAWG 2andlarger: 0.010in. (minimum) forprimary insulation 0.015in. (minimum) for outerjacket ForAWG &-4: 0.008in. (minimum) forprimary insulation 0.012in. (minimum) for outerjacket ForAWG 10: 0.005in. (minimum) forprimary insulation 0.005in. (minimum) for outerjacket SHRINKAGE: 200 + 3C for6 hours, 0.250in. (maximum) in12in. VOLTAGE WITHSTAND TEST (POSTENVIRONMENTAL): 2500 volts (rms), 60 Hz + Test performed prior to application of braid. PART NUMBER: The ** in the part numbers on page 1 shall be repiaced by color code designators, except that green shall be dark green and the designator shall be 5D. Exariipl:"AWG 2, white: CMC-0554-2-9 " *"" AWG 2, dark green: CMC-0554-2-5D PRODUCT IDENTIFICATION: Mark outer braidina contrasting color at 12inch (nominal) intervals withthe following: "CMC-0554-AWG-06090"