For more Information
please call
1-800-Belden1
General Description:
12 AWG stranded (168x34) oxygen-free high-conductivity bare copper OFC conductors, PO insulation,
conductors cabled, PVC jacket. Sequential footage marking every two feet.
Usage (Overall)
Suitable Applications: Speaker Cable, Direct Burial, Indoor/Outdoor Home Theater, In-Wall Speaker, Outdoor Speaker
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material Dia. (mm)
412 168x34 High Conductivity BC - Bare Copper 2.667
Total Number of Conductors: 4
Insulation
Insulation Material:
Insulation Material Dia. (mm)
PO - Polyolefin 3.556
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1Black
2Red
3White
4Green
Overall Nominal Diameter: 10.744 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +75°C
UL Temperature Rating: 75°C
Bulk Cable Weight: 183.049 Kg/Km
Max. Recommended Pulling Tension: 1352.253 N
Min. Bend Radius/Minor Axis: 107.950 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL3, CM
CEC/C(UL) Specification: CM
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/11/2005
EU Directive 2002/96/EC (WEEE): Yes
Page 1 of 2 05-02-2016
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1312A Multi-Conductor - Speaker Cable
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1581 Vertical Flame and FT-1 Flame Test
CSA Flame Test: FT1
Suitability
Suitability - Indoor: Yes
Suitability - Outdoor: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 6002UE
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.49215
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
73.1663
Nominal Velocity of Propagation:
VP (%)
66
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
5.2496
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
18 Amps per conductor @ 25°C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1312A 0081000 1,000 FT 132.000 LB GRAY C 4 #12 PE FRPVC
1312A 008500 500 FT 66.500 LB GRAY C 4 #12 PE FRPVC
1312A 0101000 1,000 FT 132.000 LB BLACK C 4 #12 PE FRPVC
1312A 010500 500 FT 66.500 LB BLACK C 4 #12 PE FRPVC
1312A 1SL1000 1,000 FT 132.000 LB WHITE 1SL C 4 #12 PE FRPVC
1312A 1SL500 500 FT 66.500 LB WHITE 1SL C 4 #12 PE FRPVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 1 Revision Date: 11-06-2013
© 2016 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Page 2 of 2 05-02-2016
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1312A Multi-Conductor - Speaker Cable
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Belden Wire & Cable:
1312A 0101000 1312A 010500