BCD.00288_AA_December-3-2013 3 www.power-one.com
Notes:
1. Combined power from main output and Vfan should not exceed total power rating.
2. Fan output tolerance is ± 20%.
3. Peak current for fan output is 1A.
4. Ripple is 2% up to 20% load and less than 1% above 20% load. Output noise measurement is made with a 20 MHz
bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum capacitor in parallel with a 0.1 uF ceramic capacitor.
5. Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.
6. Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.
7. Air flow over length of supply recommended (either direction) for forced air rating.
8. Derate output power per chart below.
9. Specifications subject to change without notice.
10. Warranty 2 years.
General Specifications
PFC converter variable 35 to 250 kHz, 90
kHz typical
Resonant converter: Variable 35 to 250
kHz, 90 kHz typical
Input to Output Min 5900 Vdc
Environmental
-20 to +70° C. See derating charts below.
EN55022, FCC part 15 Level B
EN55022, FCC part 15 Level B
To be controlled in end system
Electromagnetic Susceptibility
Safety