Self-Contained, AC-Operated Sensors
For complete technical information about this product, including dimensions, accessories, and specifications, see www.bannerengineering.com and search 121523
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing
so could lead to serious injury or death. This device does NOT include the
self-checking redundant circuitry necessary to allow its use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Models
Sensing Mode Model1Output Range LED
OPPOSED
T303E -
60 m (200 ft) Infrared, 950 nmT30AW3R LO
T30RW3R DO
P
POLAR RETRO
T30AW3LP LO
6 m (20 ft) Visible Red, 680 nm
T30RW3LP DO
FIXED-FIELD
T30AW3FF200 LO
200 mm (8 in) cutoff
Infrared, 880 nm
T30RW3FF200 DO
T30AW3FF400 LO
400 mm (16 in) cutoff
T30RW3FF400 DO
T30AW3FF600 LO
600 mm (24 in) cutoff
T30RW3FF600 DO
Hookups
Cabled Emitters
bn
bu 20-250V ac
QD Emitters (4-pin Micro-Style)
20-250V ac
No connection
rd/wh
rd/bk
rd
gn
All Other Cabled Models
bn
bu
bk
20-250V ac
Load
All Other QD Models (4-pin Micro-Style)
20-250V ac
No Connection
Load
rd/wh
rd
rd/bk
gn
1Standard 2 m (6.5 ft) cable models are listed. For 9 m (30 ft) cable: add suffix “W/30” (for example, T303E W/30). For 4-pin Micro-style integral QD: add suffix “Q1” (for example,
T303EQ1). A model with a QD connector requires a mating cable.
T30 Sensors - AC-Voltage Series
P/N 116162 Rev. A 2/8/2013
0 116162 7
Specifications
Supply Voltage and Current
20 to 250V ac (50/60 Hz)
Average current: 20 mA
Peak current:
200 mA at 20V ac
500 mA at 120V ac
750 mA at 250V ac
Supply Protection Circuitry
Protected against transient voltages
Output Configuration
SPST solid-state ac switch; three-wire hookup; light operate or dark op-
erate, depending on model
Light Operate: Output conducts when sensor sees its own (or the emit-
ter’s) modulated light
Dark Operate: Output conducts when the sensor sees dark
Output Rating
300 mA maximum (continuous)
Fixed-Field models: derate 5 mA/°C above +50° C (+122° F)
Inrush capability: 1 amp for 20 ms, non-repetitive
OFF-state leakage current: < 100 mA
ON-state saturation voltage: 3V at 300 mA ac; 2V @ 15 mA ac
Output Protection Circuitry
Protected against false pulse on power-up
Output Response
Time Opposed mode: 16 ms ON, 8 ms OFF
Other models: 16 ms ON and OFF
NOTE: 100 ms delay on power-up; outputs do
not conduct during this time.
Repeatability
Opposed mode: 2 ms
Other models: 4 ms
Repeatability and response are independent of signal strength
Indicators
Two LEDs (Green and Yellow)
Green ON steady: power to sensor is ON
Yellow ON steady: sensor sees light
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
Construction
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m (6.5 ft) attached cable, or 4-pin Micro-style quick-disconnect fitting
Operating Conditions
Temperature: −40° to +70° C (−40° to +158° F)
Humidity: 90% at +50° C maximum relative humidity (non-condensing)
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration;
frequency 10 to 60 Hz, max., double amplitude 0.06 in acceleration
10G). Method 213B conditions H&I (Shock: 75G with unit operating;
100G for non-operation)
Certifications
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE,
COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSE-
QUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARIS-
ING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product
previously manufactured by Banner Engineering Corp.
T30 Sensors - AC-Voltage Series
www.bannerengineering.com - tel: 763-544-3164