SDR-120 series 120W Single Output Industrial DIN RAIL with PFC Function Features : High efficiency 91% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.93 Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 years warranty SE PQ M IF 47 GL SPECIFICATION MODEL OUTPUT SDR-120-12 SDR-120-24 SDR-120-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 10A 5A 2.5A CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A RATED POWER 120W 120W 120W PEAK CURRENT 15A 7.5A 3.75A PEAK POWER Note.6 180W (3 sec.) RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p VOLTAGE ADJ. RANGE 24 ~ 28V 1.0% 48 ~ 55V 1.0% 12 ~ 14V VOLTAGE TOLERANCE Note.3 1.0% LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1500ms, 60ms/230VAC SETUP, RISE TIME 20ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT Note.7 88 ~ 264VAC 3000ms, 60ms/115VAC at full load 20ms/115VAC at full load 124 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.93/230VAC 89% 0.96/115VAC at full load EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.4A/115VAC 35A/115VAC 0.7A/230VAC 70A/230VAC LEAKAGE CURRENT <1mA / 240VAC Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE 91% 90.5% >150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds 14 ~ 17V 29 ~ 33V Protection type : Shut down o/p voltage, re-power on to recover 95 5 56 ~ 65V (TSW : detect on heatsink of power switch) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION DC OK REALY CONTACT RATINGS (max.) 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load -25 ~ +70 (Refer to output load derating curve) WORKING TEMP. 20 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE O/P-DC OK:0.5KVAC / 70% RH Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, SEMI F47, GL approved 289.9Khrs min. MIL-HDBK-217F (25 40*125.2*113.5mm (W*H*D) 0.67Kg; 20pcs/14.4Kg/1.16CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. 3 seconds max., please refer to peak loading curves. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. http://store.iiic.cc/ File Name:SDR-120-SPEC 2010-12-07 120W Single Output Industrial DIN RAIL with PFC Function SDR-120 series Mechanical Specification Unit:mm 113.5 Case No.992A 125.2 TB2 40 DC OK +V ADJ. 1 2 3 DC OK TB1 1 2 3 4 + Terminal Pin No. Assignment (TB1) 35 Pin No. 1 2 3 Assignment FG AC/N AC/L Terminal Pin No. Assignment (TB2) Pin No. 1,2 3 4 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Assignment Relay Contact DC OUTPUT -V DC OUTPUT+V Block Diagram DC OK I/P EMI FILTER & RECTIFIERS POWER SWITCHING PFC CIRCUIT RECTIFIERS & FILTER +V -V O.C.P. U.V.P. FG PFC CONTROL O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P. DC OK Relay Contact Contact Close PSU turns on / DC OK. Contact Open PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. http://store.iiic.cc/ File Name:SDR-120-SPEC 2010-12-07 SDR-120 series 120W Single Output Industrial DIN RAIL with PFC Function Peak Loading (1) (2) 180W 180W 120W 60W 100 sec. 3 sec. 15 sec. 3 sec. Derating Curve Output derating VS input voltage Others 150 100 90 For 3 sec. (typ.) 125 12V 80 Others 70 Continuous 75 LOAD (%) LOAD (%) 100 12V 60 -25 60 50 40 0 10 20 30 40 50 55 60 70 (VERTICAL) 88 AMBIENT TEMPERATURE ( ) 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz http://store.iiic.cc/ File Name:SDR-120-SPEC 2010-12-07