Rights to change data / design reserved
Edition: 02/2004
Safety Relay SR2M
2 pole 6 A
Contact data
Configuration 1 N/C contact and 1 N/O contact
or
2 C/O contact *)
Type of contact single contact, forcibly guided
1 N/C + 1N/O type A according to EN 50205
2 C/O type B according to EN 50205
Rated current 6 A
Rated voltage / max.breaking voltage AC 240 Vac / 400 Vac
Maximum breaking capacity AC 1500 VA
Contact material AgNi
Minimum contact load > 50 mW
Contact resistance w100 mc/1A/24Vdc
w20 c/ 10 mA / 5 Vdc
*) According EN50205 only 1N/O / 1N/C (11-14 and 22-21 or 12-11 and 21-24) shall be
used as forcibly guided contacts.
Features
•Forcibly guided contacts according to EN 50205
•2 pole safety relay with either
1N/O+1N/C or 2C/O contacts
•6 kV surge resistance between poles
Applications
Emergency shut-off, machine control, elevator and escalator control,
light barrier control
VZT
Technical data of approved types on request
Coil data
Nominal voltage 5...110 Vdc
Nominal coil power approx. 700 mW
Operative range 2
Coil versions
Coil Nominal Pull-in Release Coil Coil
code voltage voltage voltage resistance current
Vdc Vdc Vdc cmA
005 5 3.8 0.5 35.7+10% 140.0
006 6 4.5 0.6 51+10% 117.6
009 9 6.75 0.9 116+10% 77.6
012 12 9.0 1.2 206+10% 58.3
018 18 13.5 1.8 483+10% 37.3
021 21 15.8 2.1 630+10% 33.3
024 24 18.0 2.4 823+10% 29.2
036 36 27.0 3.6 1851+10% 19.4
040 40 30.0 4.0 2286+10% 17.5
048 48 36.0 4.8 3291+12% 14.6
060 60 45.0 6.0 5142+12% 11.7
080 80 60.0 8.0 9143+12% 8.7
110 110 82.5 11.0 17285+12% 6.4
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
F0188-C