Electrical data
Primary Nominal Current Analogue Output Signal Type
IPN (A.t.RMS) IOUT (mA)
10,25,50 4-20 AP 50 B420L
50,75,100 4-20 AP 100 B420L
100,150,200 4-20 AP 200 B420L
200,300,400 4-20 AP 400 B420L
R LLoad resistance < 350
VCSupply voltage (loop powered) +24 V DC
VdR.m.s. voltage for AC isolation test, 50/60Hz, 1 mn 5kV
Limitation of output current < 25 mA
Accuracy-Dynamic performance data
XAccuracy @ IPN, TA = 25°C (without offset) < ±1 % of IPN
εεLLinearity (0 .. ± IPN)< ±0.5 % of IPN
IOE Electrical offset current, TA = 25°C 4mA
IOT Thermal drift of IOE ±1 µA/K
TCεεGThermal drift of the gain (% of reading) ±0.1 %/K
t rResponse time @ 90% of IP < 500 ms
fFrequency bandwidth (-3 dB) 10 .. 6000 Hz
General data
TAAmbient operating temperature -20 .. +60 °C
TSAmbient storage temperature -20 .. +85 °C
mMass 90 g
Protection type IP20
Reliable isolation according to EN50178, EN61010 300 V AC
Creepage distance > 5.5 mm
EMC in accordance with EN50082-2
Plastic according to UL94V0, CTI 1
Notes : Installation and maintenance should be done with power supply disconnected.
AC Current transducer AP-B420L
Split core transducer for the electronic measurement AC waveforms
current, with galvanic isolation between the primary (High power) and
the secondary circuits (Electronic circuit). Switch selectable ranges
and RMS 4-20mA current output.
IPN = 10 .. 400 A
030708/0
Features
RMS output
Split core type
Loop powered 4-20mA current output
DIN mounting & Panel mounting
Eliminates insertion loss
Switch selectable ranges
Advantages
Large aperture for cable up to Ø18mm
High isolation between primary and
secondary circuits
Easy to mount
Applications
Automation systems
Analog current reading for remote
monitoring (e.g. motor) and software
alarms.
Panelmeters
Simple connection displays power
consumption.
LEM Components www.lem.com
Preliminary
Dimensions AP(R)-B420L (unit : mm, 1mm = 0.0394 inch)
Mechanical characteristics
General tolerance ±1 mm
Primary aperture 18.5 mm
Panel mounting 2 holes 4.0 mm
Distance between holes 40.0 mm
For panel mounting, replace M4 screws by new one (not supplied) with appropriate length to panel´s thickness.
Connections
Wires up to 2 mm
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Load Resistance vs. Supply Voltage
0
5
10
15
20
25
30
0 100 200 300 400
Load Resistance
Supply Voltage
Load
(+)
(+)
2(-)
(-)
(-)
1(+)
3none
Output
Range Switch
4-20mA
(Controller,
Meter, etc,)
AP/APR
Connector