KGZ-12
KGZ-12 Series High -Accuracy Oxygen
Sensor
Actual product appearance may vary.
Features
?
High-accuracy measurement
?
Low power consumption
?
No reference gas required
?
Linear output signal
?
No need for temperature stabilization
?
Function testing and calibration in
ambient air
?
Long life
Potential Applications
?
Heating boiler control
?
Industrial process control
?
Control of aircraft on board oxygen
generation systems
?
Automotive exhaust gas diagnostics
?
Service instruments
?
Monitoring environmental oxygen
?
Agriculture, composting, fruit storage
Description
These are high-accuracy oxygen sensors suitable for many applications. Originally
developed for boiler applications, the product range has been extended to offer
versions suitable for oxygen monitoring on board commercial and military aircraft,
exhaust gas testing for automotive and medical test equipment.
The sensors employ two ZrO2 discs with a small hermetically sealed chamber in
between. One of the discs functions as a reversible oxygen pump, which is used
to successively fill and empty the chamber. The second disc measures the ratio of
the partial pressure difference and generates a corresponding sense voltage. A
heat element produces the 700 ? C required for the ZrO2 to operate as an O2
pump.
The time taken for the pump to achieve specific minimum and maximum pressures
within this chamber is a measure of the partial oxygen pressure of the environment.
The sensors have to be operated by an electronic measuring circuit that controls
sensor operation and signal processing. This circuit can either be incorporated into
the customer? s own electronics, or be purchased as a separate box of
electronics from Honeywell.
Supporting Documentation
Product Sheet
Product Specifications
Sensor Voltage Levels
(recommended) 45 -64 -85 mV
Pump Current (recommended) 40 micro -A
Heater Supply 4.0 V (1.7 A)
Standby Heater Supply 2.0 V
Pump Resistance @ 700 °C [1292
°F] dc 1 kOhm (typ.); ac 1 kHz 120
Ohm (typ.)
Oxygen Pressure Range 2 mbar - 3 bar
Operational Temperature 700 °C [1292 °F]
Standby Temperature 500 °C [932 °F] (typ.)
Sensitivity 1.05 ms/mbar
Accuracy < 5 mbar
Response Time < 15 s
Warm Up Time < 100s
Warm Up Time from Standby < 20 s
Permissable Gas Temperature -100 °C to 250 °C [ -148 °F to 482
°F]
Gas Flow Rate 0 to 10 ms
Repetitive Permissable
Acceleration 5 g
Incidental Permissable
Acceleration 30 g
Series Name KGZ-12