MICRO SWITCHTM Military-Grade Toggle Switches TL Series Datasheet MICRO SWITCHTM TL Series Toggle Switches Honeywell MICRO SWITCHTM TL Series toggle switches are military qualified to MIL-DTL-3950, specifications for sealed toggle switches. Quality construction features include a bonded seal between the toggle lever and bushing, and between the cover and case. The robust design of the TL Series toggle is well-suited for many military, aerospace and other demanding applications where reliability is essential. These applications include environments where the panels are subjected to mechanical shock, vibration, and temperature extremes as well as environments with dust, splashing or hose-directed water. TL Series toggle switches offer a variety of circuitry and pole options to easily integrate into a number of applications. A long history in military and aerospace applications has shown the TL Series toggle provides reliable performance with long operating life under the toughest conditions. What makes our switches better? *MIL-DTL-3950 qualified switches available to meet military specifications Environmental sealing enables switches to withstand many demanding indoor and outdoor applications 1-, 2-, and 4-pole options for a variety of circuitry requirements 2- and 3-position, maintained and momentary toggle action to meet circuit and actuator requirements UL recognized, CSA certified, and CE approved for global use ATTENTION!! TL Series toggles are qualified for military duty! MILITARY QUALIFIED * GLOBAL APPROVALS MULTI-CIRCUITS * HIGH PERFORMANCE 2 sensing.honeywell.com Features and Benefits MIL-QUALIFIED AND GLOBAL APPROVALS MIL-DTL-3950 qualified switches are available to meet military/aerospace specifications. TL Series toggles' environmental sealing enables switches to withstand many demanding indoor and outdoor applications. Quality construction includes a bonded seal between the toggle lever and bushing, and between the cover and case that enables switches to withstand may demanding conditions. UL recognized, CSA certified, and CE approved for global use Military-qualified listings VARIETY OF CIRCUITRIES AND OPERATING ACTIONS TL Series' 1, 2, and 4 pole options meet a variety of circuitry requirements; while 2- and 3-position, maintained and momentary toggle action, for a breadth of circuitry and actuator requirements. They thrive in a wide range of temperatures: -65 C to 71 C [-85 F to 160 F] Locking levers reduce unintended actuation LOCKING LEVERS Optional lever locks (pull-to-unlock) require two separate actions to actuate the switch in order to prevent unintended actuation MULTIPLE CONNECTION OPTIONS MICRO SWITCHTM TL Series toggles offer three popular termination options: screw, solder lugs, and IWTS (Integrated Wire Termination Systems) EASILY CONTROLS LOW-VOLTAGE DC APPLICATIONS Toggle switches available with a choice of silver alloy or gold-plated contacts to handle a variety of electrical load requirements INNOVATIVE PRODUCT DESIGN Engineered step-design case provides added space between terminals to prevent shorting ROBUST CONSTRUCTION Built from military-grade components to achieve MIL-DTL-3950 requirements sensing.honeywell.com 3 Potential Applications MILITARY AND COMMERCIAL AIRCRAFT AND HELICOPTERS Used in fixed wing aircraft and helicopter flight decks. Honeywell has a long history of providing TL Series toggle switches in commercial and military aircraft. AVIATION GROUND SUPPORT EQUIPMENT Used to turn on and operate various components of aviation ground support equipment, such as pumps, lights, and lift platforms. MILITARY LAND VEHICLES (TRACK AND WHEELED VEHICLES) Used in military land vehicles to control lights, pumps, arming equipment, and movement control of lifts/ramps, etc. CONSTRUCTION EQUIPMENT Often used on road milling, road pavers, trenchers, and stump cutters to operate movement of machinery and/or turn on lights, pumps, etc. 4 sensing.honeywell.com MICRO SWITCHTM Military-Grade Toggle Switches Table 1. Specifications Characteristic Parameter Description military-grade toggle switch Sealing qualified to MIL-DTL-3950 Operating temperature -65 C to 71 C [-85 F to 160 F] Actuators standard, locking, special design, tab Action 2- or 3- position; momentary and maintained Mounting Bushing 15/32 in (0.47 in) O Circuitry SPST, SPDT, DPST, DPDT, 4PST, 4PDT Terminations IWTS, solder, screw, quick-connect, leadwire Contacts Silver alloy or gold-plated Amp rating Up to 20 A, ac and dc capability Approvals UL, CSA, CE Measurement 26,7 mm H x 33,5 mm W x 22,6 mm D [1.05 in H x 1.32 in W x 0.89 in D] Table 2. UL and CSA Electrical Ratings Rating code Electrical rating L192 10 amps, 125, 250, 277 Vac; 1/4 Hp, 125 Vac; 1/2 Hp, 250, 277 Vac; 3 amps, 125 Vac "L" L191 15 amps, 125, 250, 277 Vac; 1/2 Hp, 125 Vac; 1 Hp, 250, 277 Vac; 5 amps, 125 Vac "L" Table 3. Electrical Ratings (in amperes) Electrical rating code 28 Vdc 115 Vdc 250 Vdc 115 Vac, 60 Hz & 400 Hz Max. 230 Vac Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res. 1 15 20 5 0.75 0.5 10 15 3 6 2 10 15 4 0.75 0.5 7 15 2 6 3 15 20 7 0.75 0.5 15 15 4 6 4 10 18 5 0.75 0.5 8 11 2 6 5 12 20 5 0.75 0.5 15 15 4 6 6 10 18 4 0.75 0.5 8 11 2 6 sensing.honeywell.com 5 TL Series TERMINAL CIRCUIT IDENTIFICATION SPECIAL CIRCUITRIES Terminal identifications are referred to in the order guides to indicate which circuits are made in each toggle position (i.e., 1-2 refers to circuit closure through terminals 1 and 2). Catalog listings with -10, -50, and -70 suffix numbers, as shown in the order guides, have special "on-on-on" circuits, as illustrated below. TLs with -12 suffix are the same as -50 except the keyway position is maintained, and the center position circuits 2-3 and 4-5 are made. -72 is the same as -50 except that the opposite keyway position is momentary, and in the center position circuits 2-3 and 4-5 are made. One Pole -10 CIRCUITRY Two Pole No of poles Keyway Side Maint. Position Center Maint. Position Opposite Keyway Maint. Position Center Maint. Position Opposite Keyway Maint. Position Center Maint. Position Opposite Keyway Maint. Position 2 Four Pole 4 -50 CIRCUITRY TERMINALS In addition to the screw terminal listings in the order guides, IWTS (Integrated Wire Termination Systems) versions and solder turrent terminals are available. IWTS provides a reliable, completely serviceable unit which meets MIL-DTL-3950 requirements. IWTS improves maintainability since wiring bundles need not be disturbed. Leads are quickly and easily assembled or removed with an insert-extract tool. A unique three-rib (grommet style) elastomer seal protects the lead connections without potting. There are no exposed metal terminals. Versions available that will accept No. 16 wire with M39029/1-102 contact pins or No. 20 wire with MS39029/1-101 contact pins. Connections are resistant to shock, vibration, and high pull-out force. No of poles 2 4 -70 CIRCUITRY No of poles 2 4 6 sensing.honeywell.com Keyway Side Maint. Position Keyway Side Maint. Position MICRO SWITCHTM Military-Grade Toggle Switches TL (SCREW TERMINAL) 2-POSITION ORDER GUIDE Circuits Made with Toggle At: No. of poles 1 2 4 Keyway Position Standard Toggle Opposite Keyway Elect. Rating Code UL Rating Code Catalog Listing Military Number Pull-to-Unlock Toggle Add Suffix to Standard Toggle Listing D Military Number** OFF 2-3 1 L191 1TL1-2 MS24523-22 D, F, G MS24658-22 OFF* 2-3 2 L192 1TL1-4 MS24523-29 F MS24658-29 1-2* OFF 2 L192 1TL1-6 MS24523-30 F MS24658-30 1-2 2-3 1 L191 1TL1-3 MS24523-23 D, F, G MS24658-23 1-2* 2-3 2 L192 1TL1-8 MS24523-26 F MS24658-26 OFF 2-3, 5-6 3 L191 2TL1-2 MS24524-22 D, F, G MS24659-22 OFF* 2-3, 5-6 4 L192 2TL1-4 MS24524-29 F MS24659-29 1-2, 4-5* OFF 4 L192 2TL1-6 MS24524-30 F MS24659-30 1-2, 4-5 2-3, 5-6 3 L191 2TL1-3 MS24524-23 D, F, G MS24659-23 1-2, 4-5* 2-3, 5-6 4 L192 2TL1-8 MS24524-26 F MS24659-26 OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-2 MS24525-22 D, F, G MS24660-22 OFF* 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-4 MS24525-29 F MS24660-29 1-2, 4-5, 7-8, 1011* OFF 6 L192 4TL1-6 MS24525-30 F MS24660-30 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-3 MS24525-23 D, F, G MS24660-23 1-2, 4-5*, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-8 MS24525-26 F MS24660-26 * These positions are momentary. All others are maintained. ** Also add the appropriate suffix to the military number. D See page 12 for locking configurations. PULL-TO-UNLOCK OPTION When ordering pull-to-unlock toggle listings (see page 12 for configurations), add the suffix letter shown in the chart on page XXX to the standard toggle listing or the MS part number. For example, to order a 1TL1-1 pull-to-unlock toggle switch with the lever locked in the center position, add the letter E (i.e., 1TL1-1E, MS24658-21E) SOLDER TURRET TERMINAL VERSION 11TL, 12TL, and 14TL type switches with solder turrent terminals are qualified to MIL-DTL-3950. They have the same circuitry and electrical ratings as their 1TL, 2TL, and 4TL counterparts, For example, an 11TL1-2 is the same as a 1TL1-2, except it has solder turret terminals instead of screw terminals. Circuitry Type Standard Lever Lever Lock One pole 11TL MS27734 MS27737 Two pole 12TL MS27735 MS27738 Four pole 14TL MS27736 MS27739 sensing.honeywell.com 7 TL Series TL (SCREW TERMINAL) 3-POSITION ORDER GUIDE Circuits Made with Toggle At: 2 4 Military Number Add Suffix to Standard Toggle Listing D Military Number*** UL/CSA Rating Code 1 1-2 OFF 2-3 1 L191 1TL1-1 MS24523-21 ALL TYPES MS24658-21 1-2* OFF 2-3 2 L192 1TL1-5 MS24523-31 E, F, K, L M, N MS24658-31 1-2* OFF 2-3* 2 L192 1TL1-7 MS24523-27 E, L, N MS24658-27 NONE** OFF 2-3 1 L191 1TL1-21 MS24523-24 E, F, K, M MS24658-24 NONE** 1-2 2-3 1 L192 1TL1-31 MS24523-33 E, F, K, M MS24658-33 NONE** 1-2 2-3* 2 L192 1TL1-51 MS24523-32 E MS24658-32 1-2* OFF NONE** 2 L192 1TL1-61 MS24523-25 E MS24658-28 1-2, 4-5 OFF 2-3, 5-6 3 L191 2TL1-1 MS24524-21 ALL TYPES MS24659-21 1-2, 4-5* OFF 2-3, 5-6 4 L192 2TL1-5 MS24524-31 E, F, K, L, M, N MS24659-31 1-2, 4-5* OFF 2-3, 5-6* 4 L192 2TL1-7 MS24524-27 E, L, N MS24659-27 NONE** OFF 2-3, 5-6 3 L191 2TL1-21 MS24524-24 E, F, K, M MS24659-24 NONE** 1-2, 4-5 2-3, 5-6 3 L191 2TL1-31 MS24524-33 E, F, K, M MS24659-33 NONE** 1-2, 4-5 2-3, 5-6* 4 L192 2TL1-51 MS24524-32 E MS24659-32 1-2, 4-5* OFF NONE** 4 L192 2TL1-61 MS24524-28 E MS24659-28 1-2, 4-5 1-2, 5-6 2-3, 5-6 3 L191 2TL1-10 MS27407-4 ALL TYPES MS27408-4 1-2, 4-5* 1-2, 5-6 2-3, 5-6 4 L192 2TL1-50 MS27407-5 E, F, K, L, M, N MS27408-5 1-2, 4-5* 1-2, 5-6 2-3, 5-6* 4 L192 2TL1-70 MS27407-6 E, L, N MS27408-6 1-2, 4-5, 7-8, 10-11 OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-1 MS24525-21 ALL TYPES MS24660-21 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-5 MS24525-31 E, F, K, L, M, N MS24660-31 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-7 MS24525-27 E, L, N MS24660-27 NONE** OFF 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-21 MS24525-24 E, F, K, M MS24660-24 NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-31 MS24525-33 E, F, K, M MS24660-33 NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-51 MS24525-32 E MS24660-32 1-2, 4-5, 7-8, 10-11* OFF NONE** 6 L192 4TL1-61 MS24525-38 E MS24660-28 1-2, 4-5, 7-8, 10-11 2-3, 4-5 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-10 - ALL TYPES - 1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 6 L192 4TL1-50 MS27406-2 E, F, K, L, M, N MS27409-2 1-2, 4-5, 7-8, 10-11* 2-3, 4-5 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-70 - E, L, N - 1-2, 4-5, 7-8, 10-11 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 5 L191 4TL1-12 MS27406-1 ALL TYPES MS27409-1 1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12* 6 L192 4TL1-72 MS27406-3 E, L, N MS27409-3 Keyway Position Center Position Opposite Keyway Catalog Listing * These positions are momentary. All others are maintained. ** Toggle lever is blocked from these products. Toggle becomes 2-position, with center being one extreme position. *** Also add appropriate suffix letter to military number D See page 12 for locking configurations. 8 Pull-to-Unlock Toggle Elect. Rating Code No. of poles Standard Toggle sensing.honeywell.com MICRO SWITCHTM Military-Grade Toggle Switches TL (IWTS TERMINATION) 2-POSITION ORDER GUIDE Circuits Made with Toggle At: No. of poles 1 2 4 Keyway Position No. 16 Termination Opposite Keyway Elect. Rating Code UL Rating Code Catalog Listing Military Number No. 20 Termination Catalog Listing Military Number OFF 2-3 1 L191 101TL1-2 MS27722-22 101TL2-2 MS27784-22 OFF* 2-3 2 L192 101TL1-4 MS27722-29 101TL2-4 MS27784-29 1-2* OFF 2 L192 101TL1-6 MS27722-30 101TL2-6 MS27784-30 1-2 2-3 1 L191 101TL1-3 MS27722-23 101TL2-3 MS27784-23 1-2* 2-3 2 L192 101TL1-8 MS27722-26 101TL2-8 MS27784-26 OFF 2-3, 5-6 3 L191 102TL1-2 MS27723-22 102TL2-2 MS27785-22 OFF* 2-3, 5-6 4 L192 102TL1-4 MS27723-29 102TL2-4 MS27785-29 1-2, 4-5* OFF 4 L192 102TL1-6 MS27723-30 102TL2-6 MS27785-30 1-2, 4-5 2-3, 5-6 3 L191 102TL1-3 MS27723-23 102TL2-3 MS27785-23 1-2, 4-5* 2-3, 5-6 4 L192 102TL1-8 MS27723-26 102TL2-8 MS27785-26 OFF 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-2 MS27724-22 104TL2-2 MS27786-22 OFF* 2-3, 5-6, 8-9, 11-12 6 L192 104TL1-4 MS27724-29 104TL2-4 MS27786-29 1-2, 4-5, 7-8, 1011* OFF 6 L192 104TL1-6 MS27724-30 104TL2-6 MS27786-30 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-3 MS27724-23 104TL2-3 MS27786-23 1-2, 4-5, 7-8, 1011* 2-3, 5-6, 8-9, 11-12 6 L192 104TL1-8 MS27724-26 104TL2-8 MS27786-26 TL (IWTS TERMINATION) 3-POSITION ORDER GUIDE Circuits Made with Toggle At: 2 4 No. 20 Termination Keyway Position Center Position Opposite Keyway UL/CSA Rating Code 1 No. 16 Termination Elect. Rating Code No. of poles Catalog Listing 1-2 OFF 2-3 1 L191 101TL1-1 MS27722-21 101TL2-1 MS27784-21 1-2* OFF 2-3 2 L192 101TL1-5 MS27722-31 101TL2-5 MS27784-31 1-2* OFF 2-3* 2 L192 101TL1-7 MS27722-27 101TL2-7 MS27784-27 1-2, 4-5 OFF 2-3, 5-6 3 L191 102TL1-1 MS27723-21 102TL2-1 MS27785-21 1-2, 4-5* OFF 2-3, 5-6 4 L192 102TL1-5 MS27723-31 102TL2-5 MS27785-31 1-2, 4-5* OFF 2-3, 5-6* 4 L192 102TL1-7 MS27723-6 102TL2-7 MS27785-27 1-2, 4-5, 7-8, 10-11 OFF 2-3, 5-6, 8-9, 11-12 5 L191 104TL1-1 MS27724-21 104TL2-1 MS27786-21 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12 6 L192 104TL1-5 MS27724-31 104TL2-5 MS27786-31 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12* 6 L192 104TL1-7 MS27724-27 104TL2-7 MS27786-27 Military Number Catalog Listing Military Number * These positions are momentary. All others are maintained. NOTE: For TL switches featuring IWTS termination and a "pull-to-unlock" lever option, contact a Honeywell Sensing and Control representative at 1-800-537-6945. sensing.honeywell.com 9 TL Series TL SERIES 1-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS Note: Three-position switches shown 1TL1: Single pole, standard lever, screw terminals 11TL1: Single pole, standard lever, solder terminals 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 101TL1: Single pole, standard lever, IWTS terminals 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 31 7 total travel 31 7 total travel 31 7 total travel 15 30' 3 30' O 6,09 mm [O 0.24 in] 15 30' 3 30' 15 30' 3 30' O 6,09 mm [O 0.24 in] O 6,09 mm [O 0.24 in] 17,0 mm [0.67 in] 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 17,0 mm [0.67 in] 11,9 mm [0.47 in] 29,5 mm [1.16 in] 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 6,1 mm [0.24 in] 23,1 mm [0.91 in] Sealed to prevent entrance of liquids or dust 11,9 mm [0.47 in] 29,5 mm [1.16 in] 6,1 mm [0.24 in] Sealed to prevent entrance of liquids or dust 23,1 mm [0.91 in] 4,7 mm 0,38 mm [0.185 in 0.015 in] (3) 6,4 mm [0.25 in] 17,0 mm [0.67 in] 11,9 mm [0.47 in] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 6,1 mm [0.24 in] Sealed to prevent entrance of liquids or dust 36,07 mm [1.42 in] 4,57 mm dia [0.18 in dia] (3) 2,29 mm dia [0.09 in dia] (3) 28,4 mm [1.12 in] 28,4 mm [1.12 in] 4,8 mm [0.19 in] 19,05 mm [0.75 in] 4,8 mm [0.19 in] 9,7 mm [0.38 in] 3X 6-32 UNC-2A X (0.260) binding head terminal screw and lockwasher (sems) 15,7 mm [0.62 in] 28,7 mm 0,76 mm [1.130 0.030 in] 19,05 mm [0.75 in] 9,7 mm [0.38 in] 28,4 mm [1.12 in] 15,7 mm [0.62 in] 9,7 mm [0.38 in] 15,7 mm [0.62 in] Locking lever dimensions for single pole TL toggles 31 7 total travel 15 3 O 10,67 mm [O 0.42 in] 2,28 mm [0.090 in] 26,67 mm approx. pullout [1.05 in] to change position 10 sensing.honeywell.com 9,7 mm [0.38 in] Sealed construction (blue seal) MICRO SWITCHTM Military-Grade Toggle Switches TL SERIES 2-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS Note: Three-position switches shown 2TL1: Single pole, standard lever, screw terminals 12TL1: Single pole, standard lever, solder terminals O 6,09 mm [O 0.24 in] O 6,09 mm [O 0.24 in] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 34 8 total travel O 6,09 mm [O 0.24 in] 17 4 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 3,3 mm min. [0.130 in min.] Sealed to prevent entrance of liquids or dust 3,05 mm 17,0 mm [0.67 in] [0.12 in] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 11,9 mm [0.47 in] 6,09 mm [0.24 in] Sealed to prevent entrance of liquids or dust 4,57 mm dia [0.18 in dia] (6) 27,94 mm 3,3 mm min. 34,29 mm [1.10 in] [0.130 in min.] [1.35 in] 0,76 mm [0.03 in] (6) 3,3 mm min. [0.130 in min.] 33,53 mm [1.320 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] 1 2 3 1 3 22,6 mm [0.89 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] Sealed construction (blue seal) Terminals accept PIN M39029/1-102 4 6 5 4 6 5 6X 6-32 UNC-2A x (0.260) binding head terminal screw and lockwsher (sems) 9,7 mm [0.38 in] 23,1 mm max. [0.91 in max] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 37,34 mm max [1.47 in max.] 2 9,7 mm [0.38 in] 6,6 mm [0.26 in] Sealed to prevent entrance of liquids or dust 6,09 mm [0.24 in] 19,05 mm [0.75 in] 6,6 mm [0.26 in] 19,05 mm [0.75 in] 11,9 mm [0.47 in] 3,05 mm [0.12 in] 34,0 mm max. [1.34 in max.] 7,1 mm [0.28 in] 33,53 mm [1.32 in] 7,1 mm [0.28 in] 17,0 mm [0.67 in] 4,83 mm dia [0.19 in dia] (6) 2,29 mm dia [0.09 in dia] (6) 3,3 mm min. [0.130 in min.] 22,6 mm [0.89 in] 34 8 total travel 17 4 11,9 mm [0.47 in] 6,1 mm [0.24 in] 34,29 mm [1.35 in] 10,9 mm [0.43 in] 17 4 34 8 total travel 27,94 mm [1.10 in] 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 17,0 mm [0.67 in] 102TL1: Single pole, standard lever, IWTS terminals Locking lever dimensions for double pole TL toggles 34 8 total travel 17 4 O 10,67 mm [O 0.42 in] 2,28 mm [0.090 in] 26,67 mm approx. pullout [1.05 in] to change position sensing.honeywell.com 11 TL Series TL SERIES 4-POLE STANDARD ACTUATOR OPTIONS, TERMINALS, & DIMENSIONS Note: Three-position switches shown 4TL1: Four-pole, standard lever, screw terminals 14TL1: Four-pole, standard lever, solder terminals 104TL1: Four pole, standard lever, IWTS terminals 10,9 mm [0.43 in] 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 10,9 mm [0.43 in] 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] 1,93 mm 0,20 mm wide keyway [0.076 in 0.008 wide keyway] O 6,09 mm [O 0.24 in] O 6,09 mm [O 0.24 in] 10,9 mm [0.43 in] 10,9 mm [0.43 in] 34 8 total travel 17 4 34 8 total travel 34 8 total travel 17,0 mm [0.67 in] 3,05 mm [0.12 in] 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 17 4 O 6,09 mm [O 0.24 in] 11,9 mm [0.47 in] 6,09 mm [0.24 in] 3,05 mm [0.12 in] 17,01 mm [0.67 in] 15/32 - 32 UNS 2A thread to within 1,52 mm [0.060 in] of shoulder 6,1 mm [0.24 in] Sealed to prevent entrance of liquids or dust 27,94 mm 34,29 mm [1.10 in] 3,3 mm min. [0.130 in min.] [1.35 in] 17 4 17,0 mm [0.67 in] 3,05 mm [0.12 in] 0,76 mm [0.03 in] (12) 15/32 - 32 UNS-2 thread to within 1,52 mm [0.060 in] of shoulder 4,83 mm dia [0.19 in dia] (12) 11,9 mm [0.47 in] 6,09 mm [0.24 in] Sealed to prevent entrance of liquids or dust 27,94 mm [1.10 in] 3,3 mm min. [0.130 in min.] 34,29 mm [1.35 in] 3,3 mm min. [0.130 in min.] Sealed to prevent entrance of liquids or dust 37,3 mm [1.47 in] 3 1 6 5 8 4 7 11 10 9,4 mm [0.37 in] 41,7 mm [1.64 in] 9,4 mm [0.37 in] 9 33,53 mm [1.32 in] 7,1 mm [0.28 in] 19,05 mm [0.75 in] 2 3,3 mm min. [0.130 in min.] 12X 6-32 UNC-2 X (0.260) binding head terminal screw and lockwasher (sems) 4,57 mm dia [0.18 in dia] (12) 2,29 mm dia [0.09 in dia] (12) 33,53 mm [1.32 in] 9,7 mm [0.38 in] 6,6 mm [0.26 in] 6,4 mm [0.25 in] 7,1 mm [0.28 in] 11,9 mm [0.47 in] 33,53 mm [1.320 in] 9,4 mm [0.37 in] 19,05 mm [0.75 in] 12 9,7 mm [0.38 in] 1 3 9,4 mm [0.37 in] 9,7 mm [0.38 in] 10 11 34 8 total travel 17 4 O 10,67 mm [O 0.42 in] 2,28 mm [0.090 in] 26,67 mm approx. pullout [1.05 in] to change position sensing.honeywell.com 7 8 9,7 mm [0.38 in] 12 Locking lever dimensions for four-pole NT toggles 4 9,7 mm [0.38 in] 9 41,7 mm [1.64 in] 5 6 9,4 mm [0.37 in] 9,4 mm [0.37 in] 12 Terminals accept PIN M39029/1-102 2 6,6 mm [0.26 in] 41,66 mm [1.64 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] Sealed construction (blue seal) MICRO SWITCHTM Military-Grade Toggle Switches MICRO SWITCH TLTM SERIES LOCKING CONFIGURATIONS sensing.honeywell.com 13 TL Series This Honeywell datasheet supports the following MICRO SWITCHTM TL Series Toggle Switch Listings 101TL1-1 101TL1-2 101TL1-21 101TL1-2D 101TL1-2G 101TL1-3 101TL1-3D 101TL1-3F 101TL1-4 101TL144-6F 101TL1-4F 101TL1-51 101TL154-2 101TL1-6 101TL1-6F 101TL1-7 101TL2-1 101TL2133-3 101TL2197-2 101TL2197-21 101TL2-1A 101TL2-1N 101TL2-2 101TL2-21 101TL2-21M 101TL2-2D 101TL2-2F 101TL2-3 101TL2-31 101TL2-3D 101TL2-3F 101TL2-3G 101TL2-4 101TL2-5 101TL2-51 101TL255-1 101TL255-3 101TL2-5L 101TL2-5N 101TL2-6 101TL2-6F 101TL2-7 101TL2-7E 101TL2-8 101TL2834-1 101TL2834-2 101TL2834-3 101TL2834-5 101TL2834-6 101TL2834-7 101TL2841-3 101TL2841-7 101TL2887-3 101TL2887-51 101TL2887-6 101TL2887-8F 102TL1-1 102TL1-10 102TL1-10A 102TL1-10L 14 102TL1-10P 102TL1-1E 102TL1-2 102TL1-2D 102TL1-2F 102TL1-3 102TL1-3D 102TL1-3F 102TL1-3G 102TL144-70E 102TL1-5 102TL1-5F 102TL1-5K 102TL1-6 102TL1-7 102TL1-70E 102TL1-7E 102TL1-7X5 102TL1-8 102TL200-1 102TL2-1 102TL2-10 102TL2-10A 102TL2-10E 102TL2-10M 102TL2-10N 102TL2-10P 102TL2-12A 102TL2-12B 102TL2133-10 102TL2164-7 102TL2164-70 102TL2-1A 102TL2-1E 102TL2-1G 102TL2-2 102TL2-21 102TL2218-3 102TL2258-7 102TL2259-7 102TL2260-7 102TL2263-7 102TL2264-3 102TL226-5 102TL2-2D 102TL2-3 102TL2-31 102TL2-31K 102TL2-3D 102TL2-3F 102TL2-3G 102TL2-5 102TL2-50 102TL2-50K 102TL2-50N 102TL2-51 102TL2-51E 102TL255-7 102TL2-5E 102TL2-5F sensing.honeywell.com 102TL2-5L 102TL2-6F 102TL2-7 102TL2-70 102TL2-70E 102TL2-72L 102TL2-7E 102TL2-8 102TL2841-1 102TL2855-7 102TL286-51E 102TL2887-10 102TL2887-3 102TL2887-3D 102TL2887-7 102TL2887-70 102TL2887-7E 102TL2887-8 102TL2-8F 104TL1-1 104TL1-111A 104TL1-12 104TL1-12G 104TL1-12L 104TL1-2 104TL1-2D 104TL1-2G 104TL1-3 104TL1-3D 104TL1-3G 104TL1-50L 104TL2-1 104TL2-10 104TL2-10A 104TL2-111A 104TL2-12 104TL2-12A 104TL2-12E 104TL2-12L 104TL2-1A 104TL2-1D 104TL2-1E 104TL2-1N 104TL226-5 104TL2-2D 104TL2-3 104TL2-3D 104TL2-3F 104TL2-3G 104TL2-50 104TL2-50N 104TL255-10 104TL2-61 104TL2-7 104TL2-72 104TL2-7E 104TL2-8 104TL286-12A 104TL286-72E 104TL286-7E 104TL2887-3 104TL2887-72E 104TL2887-8F 104TL2-8F 11TL1-1 11TL1-2 11TL1-21 11TL1-2D 11TL1-3 11TL1-3D 11TL1-4 11TL146-2 11TL1-5 11TL1-51 11TL1-6 11TL1-61 11TL1-7 11TL1-8 11TL1-8F 12TL1-1 12TL1-10 12TL1-1A 12TL1-1D 12TL1-2 12TL124-10 12TL1-2D 12TL1-3 12TL1-31M 12TL1-3D 12TL1-3F 12TL1-3G 12TL1-4 12TL1-50 12TL1-50M 12TL1-5N 12TL1-6 12TL1-7 12TL1-70 12TL1-8 12TL1-8F 12TL887-1A 12TL887-3D 12TL887-7E 14TL1-1 14TL1-10 14TL1-10A 14TL1-12 14TL1-12E 14TL1-1A 14TL1-2 14TL1-2D 14TL1-3 14TL1-31 14TL1-3D 14TL1-3G 14TL1-8 1TL1-1 1TL11-1 1TL11-1L 1TL11-2 1TL1-13 1TL11-3 1TL11-31K 1TL11-3D 1TL11-3F 1TL11-5 1TL11-5N 1TL11-7 1TL11-8 1TL11-82 1TL11-82G 1TL119-1-A02 1TL119-2-A05 1TL119-3-A02 1TL119-3-A03 1TL119-4-A02 1TL119-6-A02 1TL119-7-A02 1TL119-8-A03 1TL119-8-A04 1TL1-1A 1TL1-1A USA 1TL1-1B 1TL1-1D 1TL1-1E 1TL1-1F 1TL1-1G 1TL1-1H 1TL1-1K 1TL1-1L 1TL1-1M 1TL1-1N 1TL1-1-NH 1TL1-1P 1TL1-2 1TL1-21 1TL1-21E 1TL1-21F 1TL1-21K 1TL1-21M 1TL127-2 1TL127-6 1TL1-2D 1TL1-2F 1TL1-2G 1TL1-2-USA 1TL1-3 1TL1-31 1TL1-31E 1TL1-31F 1TL1-31K 1TL133-1 1TL133-2 1TL133-21 1TL133-3 1TL1-3D 1TL1-3F 1TL1-3G 1TL1-3-NH 1TL1-4 1TL141-3G 1TL144-1E 1TL144-3G 1TL149-1E 1TL149-3D 1TL1-4F 1TL1-5 1TL150-3D 1TL150-7E 1TL1-51 1TL1-51E 1TL156-3D 1TL156-8 1TL1-5E 1TL1-5F 1TL1-5K 1TL1-5L 1TL1-5M 1TL1-5N 1TL1-6 1TL1-61 1TL1-61E 1TL163-7 1TL1-6F 1TL1-6-USA 1TL1-7 1TL176-3 1TL1-7E 1TL1-7L 1TL1-7N 1TL1-7-NH 1TL1-8 1TL187-2D 1TL187-3 1TL187-7 1TL187-7N 1TL1-8F 1TL211-7 1TL213-3 1TL28-5 1TL28-7 1TL343-5K 1TL372-2 1TL373-2 1TL47-1 1TL48-21 1TL48-3 1TL48-31 1TL48-7 1TL49-31E 1TL49-3D 1TL5-1 1TL51-5 1TL51-7 1TL5-2 1TL5-3 1TL55-21 1TL5-7 1TL62-3 1TL62-5 MICRO SWITCHTM Military-Grade Toggle Switches 1TL62-6 1TL62-7 1TL64-51 1TL82-2 1TL82-3 1TL82-7 1TL84-2R 1TL84-7R 1TL887-1 1TL887-1D 1TL887-1E 1TL887-1L 1TL887-1N 1TL887-2 1TL887-21 1TL887-21E 1TL887-2D 1TL887-2G 1TL887-3 1TL887-3D 1TL887-3G 1TL887-5 1TL887-51E 1TL887-5E 1TL887-5L 1TL887-6F 1TL887-7 1TL887-7E 1TL887-7N 1TL887-8 1TL889-5 1TL889-7 1TL91-1 1TL91-3 1TL91-4 1TL91-7 1TL91-8 2TL1-1 2TL1-10 2TL1-10A 2TL1-10B 2TL1-10D 2TL1-10E 2TL1-10F 2TL1-10J 2TL1-10K 2TL1-10L 2TL1-10M 2TL1-10N 2TL1-10P 2TL11-1 2TL11-10 2TL11-10A 2TL11-10L 2TL11-10N 2TL11-10P 2TL111-82 2TL1-12 2TL11-2 2TL11-205 2TL11-21 2TL1-12A 2TL1-12B 2TL1-12D 2TL1-12E 2TL1-12F 2TL1-12G 2TL1-12K 2TL1-12L 2TL1-12M 2TL1-12N 2TL1-12P 2TL11-3 2TL11-3D 2TL11-3F 2TL11-5 2TL11-50 2TL11-50E 2TL11-50K 2TL11-515K 2TL11-550 2TL11-56 2TL11-6 2TL11-6F 2TL11-7 2TL11-70 2TL11-8 2TL11-82 2TL119-12-A03 2TL119-1-A02 2TL119-7-A02 2TL1-1A 2TL1-1B 2TL1-1D 2TL1-1E 2TL1-1G 2TL1-1H 2TL1-1K 2TL1-1L 2TL1-1N 2TL1-1P 2TL1-2 2TL1-21 2TL1-21E 2TL1-21K 2TL124-10 2TL126-70-A02 2TL1-2D 2TL1-2F 2TL1-2G 2TL1-3 2TL130-21 2TL130-3 2TL1-31 2TL1-31F 2TL1-31K 2TL133-10 2TL133-3 2TL1-3D 2TL1-3D USA 2TL1-3F 2TL1-3G 2TL1-4 2TL141-10N 2TL141-3D 2TL143-21K 2TL143-3F 2TL149-1A 2TL1-4F 2TL1-5 2TL1-50 2TL150-1N 2TL150-3D 2TL1-50E 2TL1-50F 2TL1-50K 2TL1-50L 2TL1-50M 2TL1-50N 2TL1-51 2TL1-51E 2TL154-3 2TL154-7 2TL154-8 2TL1-56 2TL1-56F 2TL1-56K 2TL1-56L 2TL1-56M 2TL1-56N 2TL1-5E 2TL1-5F 2TL1-5K 2TL1-5L 2TL1-5M 2TL1-6 2TL1-61 2TL1-61E 2TL163-7 2TL163-70 2TL1-6F 2TL1-7 2TL1-70 2TL1-70E 2TL1-72 2TL1-72E 2TL1-7E 2TL1-7L 2TL1-7N 2TL1-8 2TL183-10P 2TL1-8F 2TL204-50 2TL204-7 2TL205-3D 2TL222-7E 2TL256-10A 2TL256-3 2TL256-3D 2TL256-3G 2TL256-4F 2TL256-5F 2TL262-3D 2TL28-1 2TL28-7 2TL372-2 2TL372-6 2TL47-1 2TL47-10 2TL48-3 2TL49-1A 2TL49-21E 2TL49-31E 2TL49-3G 2TL49-550L 2TL49-7E 2TL5-1 2TL51-5 2TL51-7 2TL5-2 2TL5-3 2TL5-5 2TL55-3 2TL5-7 2TL57-550 2TL57-7 2TL57-70 2TL6-1 2TL6-21 2TL62-10 2TL62-3 2TL62-5 2TL62-7 2TL62-82 2TL69-7 2TL82-10 2TL82-3 2TL84-2R 2TL84-7R 2TL863-7 2TL887-3 2TL887-3D 2TL887-56 2TL887-72 2TL887-7E 2TL889-70 2TL901-3F 2TL91-3 2TL917 2TL91-7 2TL91-8 2TL95-5 3TL32-12A 3TL32-1-3D 3TL32-2-3D 3TL32-3D 3TL55-7 4TL1-1 4TL1-10 4TL1-10A 4TL1-10E 4TL1-10L 4TL1-10M 4TL1-10P 4TL11-1 4TL11-10 4TL11-10A 4TL11-10B 4TL11-10K 4TL11-11A 4TL11-12 4TL11-12A 4TL11-12H 4TL11-12K 4TL111-72 4TL11-1L 4TL1-12 4TL11-2 4TL112A 4TL1-12A 4TL1-12B 4TL1-12D 4TL1-12E 4TL1-12L 4TL1-12M 4TL1-12N 4TL1-12P 4TL11-3 4TL11-31 4TL11-3D 4TL11-5 4TL11-50 4TL11-50K 4TL11-50M 4TL11-51 4TL11-550 4TL11-558E 4TL11-58P 4TL11-7 4TL11-76 4TL11-8 4TL11-82 4TL11-82G 4TL1-1A 4TL1-1D 4TL1-1E 4TL1-1L 4TL1-1M 4TL1-1N 4TL1-1P 4TL1-2 4TL1-21 4TL1-21F 4TL1-21K 4TL127-3 4TL1-2D 4TL1-2F 4TL1-2G 4TL1-3 4TL1-31 4TL1-31K 4TL132-12 4TL1-3D 4TL1-3F 4TL1-3G 4TL1-4 4TL141-3D 4TL141-3G 4TL143-3D 4TL143-3G 4TL144-1E 4TL144-7E 4TL149-3D 4TL1-5 4TL1-50 4TL150-3D 4TL1-50E 4TL1-50F 4TL1-50K 4TL1-50L 4TL1-50M 4TL1-50N 4TL1-51 4TL153-1 4TL159-3 4TL1-5K 4TL15L 4TL1-5L 4TL1-5N 4TL1-6 4TL1-61 4TL1-6F 4TL1-7 4TL1-70 4TL1-70E 4TL1-70N 4TL1-72 4TL1-72E 4TL1-7E 4TL1-7L 4TL1-8 4TL187-10A 4TL187-12 4TL1-8F 4TL247-550B 4TL250-1L-S 4TL250-50K 4TL32-3D 4TL35-3D 4TL47-12 4TL49-12A 4TL5-1 4TL5-3D 4TL57-1 4TL62-3 4TL62-7 4TL66-1L 4TL82-72 4TL836-3D 4TL837-3D 4TL839-3D 4TL84-7R 4TL887-12 4TL887-12A 4TL887-2D 4TL887-3D 4TL887-51E 4TL91-5 sensing.honeywell.com 15 TL Series ADDITIONAL INFORMATION The following associated literature is available on the Web (sensing.honeywell.com): * Product installation instructions * Product range guide * Product application-specific information - Flight deck toggle switches WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. - Sensors and switches in front loaders WARNING - Sensors and switches in mobile cranes - Sensors and switches in oil rig applications MISUSE OF DOCUMENTATION * * The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. 16 sensing.honeywell.com Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell's sensing and control products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 005430-1-EN IL50 GLO October 2013 Copyright (c) 2013 Honeywell International Inc. All rights reserved.