D A T A - S H E E T
Engineering
BRUSHLESS AXIAL COOLING FANS
Customer
Adda Model No AD0412HB-C50 P.S:
Samples attached Piece(s),
Safety Approval UL,CUL,TUV,CE
ITEM SPECIFICATION / CONDITION
DIMENSIONS 40x40x20 mm
BEARING TYPE BALL
RATED VOLTAGE 12.0 VDC
OPERATING VOLTAGE RANGE 10.8 VDC 13.2 VDC
 STARTUP VOLTAGE 9.0 VDC , NORMAL
REAL CURRENT 0.086 Amp
REAL POWER 1.032 Watt
RATED CURRENT 0.10 Amp + 10 %MAX
RATED POWER 1.20 Watt
RATED SPEED 7800 RPM ± 10 %
(IN FREE AIR AT RATED VOLTAGE)
AIR FLOW 8.800 CFM (min.: 7.920 CFM)
AIR FLOW 0.249 CMM (min.: 0.224 CMM)
(IN FREE AIR AT RATED VOLTAGE)
STATIC AIR PRESSURE 0.280 Inch H2O(min.: 0.226
STATIC AIR PRESSURE 7.112 mm H2O(min.: 5.760
(IN FREE AIR AT RATED VOLTAGE)
NOISE LEVEL 36.0 dB (A) (max.: 40.0 dB(A))
MOTOR PROTECTION BY IC
POLARITY PROTECTION NO
CONNECTION LEAD TYPE WIRE, AWG# 26
LIFE EXPECTANCY 70000 Hours at 40/ 65% RH
NET WEIGHT 28 Gram.
PACKING 500 pcs. Per Export Carton.
(T1)
Ref: (RoHS)
Printed On:
AD0412HB-C50 P.S: (T1) Page 1/4
12/05/14
mm H2O)
ADDA CORPORATION
Specifications
Inch H2O)
Model No.:
Unless otherwise stated, the relative humidity is 65%, and the temperature is 25oC for the standard testing.
Should you have any doubt, please refer to the environmental conditions specified in the acknowledgement
document.
TUV:EN 60950-1:2006+A11
UL:UL507
CE:EN 61000-6-1:2007
EN 61000-6-3:2007
2012.05.14
發行章
SPECIFICATION
Page 2/4
ADDA CORPORATION Model No.: AD0412HB-C50 P.S:(T1)
10 SCOPE
1.1 If the information or other related document is inconsistent with this acknowledgement
document, please refer to the acknowledge document.
1.2 This documentation defines the mechanical & electrical characteristics of DC brushless fans.
1.3 The specification of this product is described in details in the acknowledgement document. No
guarantee is given to our product under the use of over specifications.
1.4 For any change or amendment to the specifications, such change will be noticed in writing
beforehand.
1.5 If the product is used on the MIS system, please specify the specification in the purchase
order.
20 MATERIAL
21 Frame : UL94V-0 Glass Filled polyester (P.B.T)
22 Fan Blade : UL94V-0 Glass Filled polyester (P.B.T)
23 Bearing Sys. : ( ) Sleeve, oil impregnated.
(V ) Two Ball Bearing
( ) One Ball one Sleeve
( ) Hypro Bearing
( ) FDB Bearing
24 RoHS : (V ) YES
HF : ( ) YES
30 DIMENSIONS & CONSTRUCTION
All dimensions, Direction of rotation and air flow were
specified as per drawing attached.
40 CHARACTERISTICS & DEFINITION
41 All rated characteristics were specified as per data sheet enclosed.
42 Rated CurrentRated Current shall be measured after 3 minutes of
continuous rotation at rated voltage.
43 Rated Speed Rated Speed shall be measured after 3 minutes.
of continuous rotation at rated voltage.
44 Start Voltage The voltage which is able to start the fan to operate by
suddenly switching ’ON ’.
45 Input Power Input Power shall be measured after 3 minutes of
continuous rotation at rated voltage.
46 Locked Rotor CurrentLocked current shall be measured within one minute
of rotor locked, after 3 minutes of continuous rotation at rated voltage in clean air.
47 Air Flow & Static PressureThe air flow data and static pressures should
be determined in accordance with AMCA-210 standard
in a doublechamber testing with intake – side measurement.
48 Noise Level The measurement of noise level is carried out with reference
to CNS8753 in an anechoic chamber with the microphone positioned 1 meter
from the air intake. Testing fan shall be hung in clean air .
NOISE LEVEL MEASUREMENT
Mic. Fan
Direction
of air flow
>>>>>>>>
<---------- 1 mtr. ---------->
2012.05.14
發行章
SPECIFICATION
Page 3/4ADDA CORPORATION Model No.: AD0412HB-C50 P.S:(T1)
5.0 MECHANICAL INSPECTION
5.1 Rotation Direction
Counterclockwise when look into impeller side.
5.2 Protection
All fans have integrated protection against locked rotor condition so that there will be no
damage to winding or any electronic component.
Restarting is automatic as soon as any constraint to rotation has been released.
As fan placed at dead angle position, and the switch was changed from off to on. Restarting
was automatic normal as soon as and proved that this fan is good fan.
5.3 Locked Rotor Protection
No damage shall be found after 72 hours continuously at condition of rotation locked.
Restarting is automatic as soon as constraint to running has been released.
5.4 Avoid the damage, check the correct voltage and proper polarity before connecting with
power.
5.5 Free Drop Shock
In minimum package condition, the fan should withstand drops on any three faces from a
height of 30cm onto a wood board of 10mm thick.
5.6 Please do not stick a grease and/or an oil to the fan housing or blade which may have a harmful
influence by a chemical reaction at high humidity.
5.7 If the fan is reinstalled, please pay special attention to the noise due to the vibration (or resonance).
5.8 During the testing of the fan, please make sure the finger guard is used for safety.
6.0 ELECTRICAL INSPECTION
6.1 Insulation Resistance
Not less than 10M ohm between housing and positive end of lead wire (red) at 500V DC.
6.2 Dielectric Strength
No damage should be found at 500 VAC for 60 seconds, measured with 1mA trip current
between housing and positive end of lead wire.
6.3 Life Expectancy
The continous duty life at given temperature after which, 90% of testing units shall still be
running.
6.4 While the fan is running, do not intentionally lock the fan for a long time since the overheating of
the motor produced by the long-time locking will damage the fan.
7.0 ENVIRONMENTAL
7.1 Improper use such as disassembling the fan, being covered with dust, or dipping the fan in
water that results in defects is not covered in the warranty. Do not use the fan in the
environment with corrosive air or liquid.
7.2 Operating Temperature / Humidity
-10 to +70 at humidity 65%+/-20% RH.
7.3 Storage Temperature
All function shall be normal after 500 hours storage at -40 to +70 with a 24 hour recovery
period at room temperature.
7.4 Humidity
After 96 hours, 95% RH, 40+/-2 per MIL-STD-202F, method 103B humidity test, the
measured data on insulation resistance and dielectric strength shall meet the specificaiton.
7.5 Do not place or store the fan in the environment with high/low temperature/humidity. Do not
store the fan for over 6 months; even if the fan is stored in room temperature for over 6
months, the fan may have the electric current leakage.
2012.05.14
發行章
SPECIFICATION
ADDA CORPORATION Page 4/4Model No.: AD0412HB-C50 P.S:(T1)
8.0 REMARKS
8.1 Material and construction are subject to change without
advance notice. The changes should be within specification.
8.2 All fans shall meet the quality inspection under sampling
plan MIL-STD-105E as follow:
Critical 0.25%
Major 1.00%
Minor 2.50%
9.0 OUTLINE STYLING & DIMENSIONS
LEAD WIRES : UL 1007, AWG26, L = 295 +/- 10 mm
Red = positive ; Black = negative.
10.0 Notes:
10.1 Please do not touch and push Fan Blade with fingers or others,
fan blade and ball bearings may be damaged and it causes noise defect.
10.2 Do not carry the fan by its lead wires.
10.3 lf the fan does not have the polarity protection function, the connection of the
colored wires should be red + red, and black + black, or else the fan will be
damaged in no time.
10.4 For the models without reverse connection of polarity protection, please do not
connect the lead wire in reverse
10.5 Please don't install this fan in series with 2x voltage inputs. For example, if a single
fan rated at 12V, then don't install two of them in series with 24V input.
10.6.Every specific fan is designed for its certain application (project). Therefore, if you want to
use this fan in other application (project), please inform ADDA first so that we can confirm
whether there is any issue which might be incurred from the reason of this different
application (project) or not.
10.7 The"Life Expectancy" of this fan has not been evaluated for use in combination with any
end application. Therefore,the Life Expectancy in the Test Reports(L10 and MTTF Report)
that relate to this fan is for reference only and shall not construe any kind of warranty of
ADDA to the life of any specific fan,either expressed or implied.
10.8 The period of product warranty,unless otherwise agreed by ADDA in written,shall be 12 months
staring from the date of production.