Place hero product image here
shorter square image space available.
CORCOM FB SERIES
Standard Performance FBL
INDUSTRIAL /// CORCOM FB SERIES STANDARD PERFORMANCE FBL
TE Connectivity (TE) adds more range to the FB series product line with new part
numbers designated with FBL. FBL is part of the FB series and is targeted toward
applications that need standard EMI performance levels. LED Drivers have dierent
levels of integrated filtering but when connected to a load the filtering may not
be enough to attenuate the conducted emissions. The FB series oers standard
performance filtering with the FBL designated filters and high performance with the
FB designated filters. In addition, lighting applications can reach higher currents and
the 10 and 20A versions of the FBL products will satisfy those types of applications.
Designed to work with lighting applications that require 300 VAC.
BENEFITS
Maximize space with compact size
Offers standard performance filtering
Designed to work with lighting applications that require 300 VAC
Ambient temperature 50° C and rated to 40°C (20BL3) allows the filter
reach higher currents
APPLICATIONS
Fluorescent ballasts
LED displays
Oce and hospital lighting
Architectural lighting
Instrumentation lighting
Outdoor signage
UV curing lights
Lower current industrial applications
(AC or DC rated)
1FBL3
3FBL3
5FBL3
20FBL3
10FBL3
INDUSTRIAL /// CORCOM FB SERIES STANDARD PERFORMANCE FBL
Corcom FB Series Standard Performance FBL
ELECTRICAL
PRODUCT INFORMATION
Description Catalog PN Part Number
1A FBL Version 1FBL3 6-1609091-4
3A FBL Version 3FBL3 6-1609091-5
5A FBL Version 5FBL3 6-1609091-6
10A FBL Version 10FBL3 6-1609091-7
20A FBL Version 20FBL3 6-1609091-8
CASE DIMENSIONS
Part Number (max) (max) (max) +.015
+.38 (max)
1FBL3 0.96
24.4
1.82
46.2
0.66
16.8
2.125
53.98
2.53
64.3
3FBL3 & 5FBL3 1.32
33.5
1.82
46.2
0.78
19.8
2.125
53.98
2.53
64.3
10FBL3 1.32
33.5
1.82
46.2
1.16
29.5
2.125
53.98
2.53
64.3
20FBL3 2.07
52.58
2.065
52.45
1.16
29.5
2.375
60.33
2.81
71.37
INSERTION LOSS DATA Frequency — MHz
Part Number 0.15 0.5 1 5 10 30
1FBL3 15 29 35 45 45 48
3FBL3 15 29 35 45 45 48
5FBL3 7 19 23 34 37 42
10FBL3 7 19 23 34 37 42
20FBL3 7 19 23 34 37 42
Maximum leakage current
each line to ground:
@ 300VAC
60 Hz 0.30 mA
@ 120 VAC
60 Hz 0.12 mA
Hipot rating (one minute):
Line to Ground: 2263 VDC
Line to Line: 2263 VDC
Rated voltage (max.): 300 VAC
Operating frequency: 50/60 Hz
Rated current - FBL: 1, 3, 5, 10 and 20A
ELECTRICAL SCHEMATICS
FBL Series
SPECIFICATIONS
cURus Recognized
te.com
Corcom, TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be
trademarks of their respective owners.
While TE has made every reasonable eort to ensure the accuracy of the information in this brochure, TE does not guarantee that it is error-free, nor does TE make any other
representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained
herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties
of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are
subject to change without notice. Consult TE for the latest dimensions and design specifications.
© 2018 TE Connectivity. All Rights Reserved.
1-1773961-9  09/2018   JN